Records from 2001 to 2026. Most recent: inspection, 19 February 2026.
Inspection history · 48
19 February 2026
COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8312781
9 September 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7997735
28 March 2024
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7886345
12 December 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7838234
30 August 2023
COC-CHEM & TVE Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7777563
30 August 2022
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7546838
19 July 2021
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7252473
28 May 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7213563
24 May 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7206179
11 March 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7154501
10 January 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7122384
3 August 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7056977
20 July 2020
PSC B · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7011577
5 October 2019
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6824643
22 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6519917
4 August 2018
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6499743
20 October 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6290780
3 June 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6164382
14 May 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6145698
27 March 2017
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6107387
5 September 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3842394
21 February 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3416101
5 March 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3158771
20 February 2008
Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3150221
22 September 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3063615
7 September 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3045971
9 March 2007
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2885101
19 February 2007
COC-CHEM Renew
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2874125
31 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2613576
24 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2612544
13 January 2006
COC-CHEM Annual · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2566571
7 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2384186
7 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2385046
1 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2376451
1 March 2005
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2301254
25 January 2005
ISPS III Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2279953
9 September 2004
PII Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2190913
8 January 2004
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1978775
7 September 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1898723
5 January 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1725989
9 September 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1673059
12 August 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1660014
20 April 2002
MARPOL Annex II Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1615380
16 April 2002
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1606587
2 January 2002
Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1474063
8 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 296180
2 November 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295948
28 March 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290618
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 March 2024
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL REPORTED COLLISION WITH TUG BOAT, THE JUDGE, UPON TRANSITING UNDER PILOTAGE FROM ANCHORAGE TO OIL DOCK 8. VESSEL SUSTAINED TWO 12 X 8 INCH DENTS ON STARBOARD BOW IN VINCITY OF FR#79. PER VESSEL'S PLAN, DNV CLASS SURVEYOR IS TO CONDUCT INTERNAL AND EXTERNAL INSPECTION OF THE DAMAGED AREA OF THE HULL AND BALLAST TANK. VESSEL SHALL SUBMIT SATISFACTORY CLASS REPORT TO US COAST GUARD PRIOR TO DEPARTING CORPUS CHRISTI COTP ZONE.
74 SOLAS (04) I/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2024
Resolution: Received satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 20 July 2020
Resolved
For tankers of 20,000 Tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system. PSCO observed nitogren inert gas system inoperable while attempting to test high temp shutdown. Crew noted it was due to overheating. Prior to conducting cargo operations vessel must demonstrate that IG system is fully functioning.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2020
Resolved 31 July 2020
Resolution: Vessel made repairs to the satifaction of class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 August 2018
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED MULTIPLE WIRE RUN BULKHEAD PENETRATIONS THROUGHOUT MACHINERY SPACES FILLED WITH UNKNOWN FOAM SPRAY ALONG WITH CARDBOARD USED TO HOLD FOAM IN PLACE DURING INSTALLATION. OBSERVED TEMPORARY VENTILATION DUCTING IN PLACE BOTH IN THE COMPRESSED AIR ROOM COOLING THE AFT COMPRESSOR AND THE TRANSFORMER ROOM PROVIDING COOLING VENTILATION TO THE ELECTRICIANS STORE.
SOLAS 74 (2001) CH.I/11(b) , ACTION 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 20 August 2018
Resolution: DNV-GL PROVIDED SURVEY STATING THAT UNAUTHORIZED MATERIAL HAD BEEN REPLACED WITH COMPOUND MEETING A0-60 IMO-754(18) TEST.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 August 2018
Resolved
GENERAL ARRANGEMENTS PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIP'S OFFICERS, SHOWING CLEARLY FOR EACH DECK MEANS OF ACCESS TO DIFFERENT COMPARTMENTS. PSCO OBSERVED AN ACCESS DOOR LEADING FROM THE ELECTRICIANS WORKSHOP TO THE ENGINE CONTROL ROOM THAT WAS NOT INDICATED ON THE FIRE CONTROL PLAN. ALSO OBSERVED DOOR FRAME WITHOUT A DOOR LEADING FROM ELECTRICIANS WORKSHOP TO ELECTRICAL STOOR ROOM WHICH WAS IDENTIFIED AS A DOOR ON THE FIRE CONTROL PLAN.
SOLAS 74 (2001) CH.II-2/15.2.4 , ACTION 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 20 August 2018
Resolution: DNV-GL PROVIDED DOCUMENTATION STATING THAT THE CURRENT DOOR ARRANGEMENT IN THE ENGINE CONTROL ROOM IS ACCEPTABLE AND THAT THE FIRE CONTROL PLAN HAS BEEN AMENDED.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 March 2017
Resolved
0725-PSCO observed more than 30 water spray nozzles were not functioning, certain spots where nozzles were marked on the diagram were plugged, and a valve connection was in place of a nozzle. Provide class report attesting to proper operation of deck spray system prior to cargo operations with cargoes requiring water spray system. SOLAS 74 (2014) II-2.14.2.1.2 ac
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 14 May 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 20 February 2008
Resolved
Numerous water spray nozzles were missing or providing an insufficient water blanket. Prior to the carriage of propylene oxide, the vessel is required to rectify this deficiency to the satisfaction of the certificate issuing authority and submit a report attesting to the satisfactory operation of the water spray system to the coast guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 March 2008
Resolution: Cleared by class (BV) report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2005
Resolved
The oily water separator (OWS) would not operate properly. a requirement was issued prohibiting the vessel from operating the OWS until the certificate issuing authority thoroughly test and attests to the proper operation of the OWS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2005
Resolved 1 March 2005
Resolution: Received class report from DNV satisfying requirement. The class report stated that the solenoid valves were found defective and replaced. The OWS system and content meter were thoroughly tested found operating satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 September 2004
Resolved
BLACK OIL WAS FOUND INSIDE OVERBOARD DISCHARGE PIPE DOWNSTREAM OF THREE-WAY VALVE. THIS LEADS TO THE COLCLUSION THAT THERS IS A FAILURE IN THE THREE-WAY VALVE OPERATION OR THE SENSING EQUIPMENT. VSL MUST HAVE CLASS COMPLETE A REPORT ATTESTING TO THE PROPER OPERATION OF THE OWS THREE-WAY VALVE AND SENSING EQUIPMENT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 September 2004
Resolution: CLASS REPORT RECEIVED CLEARING DEF.