Records from 2001 to 2011. Most recent: inspection, 3 January 2011.
Inspection history · 16
3 January 2011
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3913011
24 December 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3384653
21 March 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3168931
18 March 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3167036
22 January 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2859789
11 January 2007
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2854359
1 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2791095
30 September 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2791994
31 May 2006
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2666172
25 May 2006
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2659304
6 January 2006
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2559911
5 January 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2561043
28 July 2004
ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2148282
4 November 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1701064
4 November 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1701140
1 August 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 292200
Communications › Radio Communications › EPIRB
Issued 3 January 2011
Resolved
1671 VESSEL'S SATELLITE EPIRB FAILED AN OPERATIONAL TEST IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. VESSEL SHALL HAVE A SATELLITE EPIRB WHICH FUNCTIONS AS PER SOLAS REGULATION. SOLAS74(09CONS), CH.IV/7.1.6, 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2011
Resolution: RECEIVED REPORT THAT A NEW EPIRB HAS BEEN RECIEVED, INSTALLED AND REGISTERED.
Engineering › Steam System (auxiliary) › Piping
Issued 3 January 2011
Resolved
1499 TWO CEMENT BOXES FOUND IN THE ENGINE ROOM BILGE ON STEAM LINES FORWARD OF FUEL OIL TRANSFER PUMP. SOLAS74/CH.I/R.11 70A.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2013
Resolution: Repaired see attached class report.
Construction/Loadline › Structures › Door
Issued 3 January 2011
Resolved
0700 "A" CLASS SELF CLOSING DOOR LEADING FROM UPPER DECK TO A-DECK LATCHING MECHANISM IS INOPERABLE COMPROMISING INTEGRITY OF THE FIRE BOUNDARY. THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED. SOLAS74(01 CONS), CH.II-2,R.47.1 70A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2013
Resolution: Repaired. See attached class report.
Operations/Management › Dedicated Clean Ballast Tanks › Flushing Pump/Piping System
Issued 3 January 2011
Resolved
1499 A SOFT PATCH REPAIR WAS FOUND ON PIPING LEADING TO NO.2 BALLAST PUMP. REPAIR MUST BE APPROVED BY THE CERTIFICATE ISSUEING AUTHORITY. SOLAS74/CH.I/R.11 70A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2013
Resolution: Cropped and renewed. See attached class report.
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 18 March 2008
Resolved
Received notification that the vessel is experiencing difficulties with main propulsion.
Action required: 705 - Other - as specified
Resolved 20 March 2008
Resolution: Received class report attesting to the repair of the main engine.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 31 May 2006
Resolved
Update SOLAS Training Manual to be ship specific. All life saving/fire fighting equipment listed in manual should reflect equipment onboard. Also, ensure crew muster lists/assigned duties are current.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 January 2007