MAURY USCG vessel records Sign in
← All vessels

NORTH COVE LAUNCH

NORTH COVE LAUNCH is a 1974 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2001, most recently in May 2026, along with 20 deficiencies and 1 operational control.

Records from 2001 to 2026. Most recent: inspection, 8 May 2026.

Built
1974
Last inspected
8 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-19616

Inspections, by type

Years with a record 23 calendar years (2001–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

8 May 2026 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8371178
9 May 2025 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8131851
8 May 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7908469
8 May 2023 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7642719
13 July 2022 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7472211
2 June 2021 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7212121
15 July 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6991173
20 June 2019 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6720061
10 May 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6680979
13 June 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6443572
19 July 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6215205
1 May 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6136580
21 July 2016 Spot Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5949283
11 May 2016 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5870775
16 July 2015 Spot Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5187302
2 May 2014 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4858765
14 May 2012 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4311235
10 July 2009 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3529960
21 April 2009 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3457415
15 May 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3207300
29 January 2008 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3138464
14 May 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2931208
16 June 2006 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2681460
12 May 2006 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2647309
20 May 2005 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2363112
21 April 2005 Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2340387
4 June 2004 Annual Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2115106
29 May 2003 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1804590
20 March 2003 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1760392
21 August 2002 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1663748
24 May 2001 Hull Examination · Initial Certification
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1465016
22 April 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1064832

Deficiency record · 20

Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 July 2017 Resolved
Prove proper operation of fixed system
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 24 August 2017
Resolution: System works as designed.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 19 July 2017 Resolved
Provide new battery for the float light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 24 August 2017
Resolution: Battery installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2014 Resolved
Remount electrical cables currently attached to exhuast hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 23 May 2014
Resolution: Electrical cables remounted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 May 2014 Resolved
Repair/replace raw water intake hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 23 May 2014
Resolution: Wawter leak secured. Replaced water pump shaft seals and bearings, which were determined to be the cause of the leak.
Engineering › Sea-water System (primary cooling) › Valve
Issued 2 May 2014 Resolved
Prove operability of seacock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 23 May 2014
Resolution: Lubricated and exercised seacock.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 May 2014 Resolved
Renew retro-reflective tape on lifejackets and ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 23 May 2014
Resolution: New retro installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2014 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 23 May 2014
Resolution: Expired items renewed.
Engineering › Fuel Oil Service System › Piping
Issued 14 May 2012 Resolved
Provide double hose clamps on fuel lines and engine cooling lines.
Due 24 May 2012
Resolved 25 June 2012
Documentation › Certificates/Documents › Stability Letter
Issued 14 May 2012 Resolved
Letter unavailable/missing. Will be redrafting to provide the vessel.
Due 24 May 2012
Resolved 25 May 2012
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 May 2012 Resolved
Provide new retro tape for child PFDs and adult PFDs as required.
Due 24 May 2012
Resolved 25 May 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 14 May 2012 Resolved
Re-tag B1 fire extinguisher and fire boy with correct year. Provide last service report.
Due 24 May 2012
Resolved 25 May 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 May 2012 Resolved
Provide documentation of training and drills for new season.
Due 24 May 2012
Resolved 25 May 2012
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2008 Resolved
Vessel does not have the required number of lifejackets on board. 15 Type I lifejackets are required and vessel had 13 Type 1 and 3 Type II. Vessel is limited to carying 13 persons until 15 lifejackets are on board.
Due 29 May 2008
Resolved 20 May 2008
Resolution: 3 addiional Type I PFDs provided.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 May 2008 Resolved
Make repairs to engine shutdown on Installed Fixed Firefighting system. Installed Fixed Firefighting system did not shut off engine when electrical lead was disconnected. Vessel is restricted from carrying passengers until fixed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2008
Resolved 20 May 2008
Resolution: FFE engine shutdown repaired.
Stability › Incline Test › General
Issued 29 January 2008 Resolved
Vessel required to complete simplified stability test prior to next drydock.
Due 31 May 2009
Resolved 21 May 2009
Resolution: Vessel Completed Simplififed Stability Test
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 May 2006 Resolved
Replace missing flame screen.
Due 19 May 2006
Resolved 19 May 2006
Resolution: Purchased new flame screen.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 June 2004 Resolved
Provide emergancy lighting.
Due 6 July 2004
Resolved 18 June 2004
Resolution: Sighted 2 flashlights
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 4 June 2004 Resolved
Prove proper operation of F/F system
Due 6 August 2004
Resolved 18 August 2004
Resolution: Tested sat.
Lifesaving › Lifejacket/PFD (Type V) › Lights
Issued 4 June 2004 Resolved
Provide float light for ring buoy
Due 9 July 2004
Resolved 15 July 2004
Resolution: Cleared by fax
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 4 June 2004 Resolved
Provide horn and bell
Due 9 July 2004
Resolved 18 June 2004
Resolution: Sighted

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.