MAURY USCG vessel records
← All vessels

VICTORY

Built
1981
Last inspected
4 November 2020
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 November 2020
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6137
196407
Flag
UNITED STATES
Maury page id
psix-196407

Documentation record

Registered dimensions (L × B × D)196.3 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)196.3 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 3,834 / net 1,150
BuilderUNDERWATER COMPL TEAM INC · NEW IBERIA, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPERTH AMBOY, NJ
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
3834 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
1150 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 125 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 4 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

4 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7089770
17 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6514744
25 May 2017 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6153070
29 March 2017 Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6114424
27 January 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6078329
12 December 2016 Deficiency Check · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6056138
22 September 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6008762
14 September 2016 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6000510
29 August 2016 Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5986599
11 August 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5969512
10 August 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5974582
6 August 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5974377
5 August 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5976689
13 June 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5906344
9 June 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5902069
13 May 2016 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5877704
11 May 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5874497
9 May 2016 Internal Structural Exam · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5870731
1 March 2016 Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5824222
5 February 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5813308
3 January 2016 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5791863

Deficiency record · 125

10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018 Resolved
IMO: Vsl is broadcasting no IMO #, NAME: Vsl is broadcasting incorrect Name, LENGTH DIFF: greater/smaller than expected vessel length
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 November 2018
Resolution: Vessel has not broadcast any information via AIS since 2018.08.29.
Electrical › Electric Generation Source (service) › Generator
Issued 25 May 2017 Resolved
Make proper repairs to the #4 SSDG and prove proper operation including Sync/Parallel ops.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2017
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 May 2017 Resolved
Complete DAPI audit and crew drills.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 25 May 2017 Resolved
Provide properly licensed and trained crew.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.
Personnel › Training › Familiarization Training
Issued 25 May 2017 Resolved
Establish training program for crew.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.
Electrical › Electric Generation Source (service) › Generator
Issued 25 May 2017 Resolved
Demonstrate alarms and safeties on the #4 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 25 May 2017 Resolved
Provide VGP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 May 2017 Resolved
Provide current navigation chart publications for the area the vessel is operating in.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2017
Resolved 27 June 2017
Resolution: corrected
Lifesaving › Inflatable Buoyant Apparatus › Quantity
Issued 25 May 2017 Resolved
Provide one 100 person IBA. Persons allowed onboard reduced to 600 until provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 27 June 2017
Resolution: corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 May 2017 Resolved
Replace or reposition exhaust blankets on Both MDE's and Both SSDG's so that no portions of exhaust piping are exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Charge Air Cooling
Issued 25 May 2017 Resolved
Prove proper operation of all duplex R/W strainers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 25 May 2017 Resolved
Replace deteriorated exhaust R/W cooling hose on #3 MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 25 May 2017 Resolved
Replace/re-align R/W pump discharge hose on #3 MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 May 2017 Resolved
Install machinery guards around rotating accessory drives on #2,3,4 SSDG's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 May 2017 Resolved
Identify disconnected ground wire near batteries outboard of the #2 SSDG and remove if not needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 25 May 2017 Resolved
Reconnect ground wire onto rudder; port side steering compt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2017 Resolved
Renew broken emergency light in the port steering compt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 May 2017 Resolved
Renew pipe support bracket for R/W discharge pipe #3 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 May 2017 Resolved
Reconfigure remote F/O shut off valves for stbd MDE's to fully close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 May 2017 Resolved
Re-fasten cover to slop tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 May 2017 Resolved
Replace latch assembly on A-Class door to surveillance room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 27 June 2017
Resolution: corrected
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 May 2017 Resolved
Repair A-Class door to Slot Room (hole in door and insufficient floor clearance).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 May 2017 Resolved
Repair and Demonstrate proper operation of PA system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 27 June 2017
Resolution: corrected
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 May 2017 Resolved
Establish and maintain waste management plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 25 May 2017 Resolved
Provide light and globe on port side 03 deck light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 May 2017 Resolved
Provide indicator for port side 02 deck forward damper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Conductor
Issued 25 May 2017 Resolved
Properly support wiring and remove dead end wires in the IT / Security room on 02 deck forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 May 2017 Resolved
Clean out deck drains in the forward Dolphin Bar and the main deck bar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Conductor
Issued 25 May 2017 Resolved
Remove extension cords from the outside Dolphin Bar.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 May 2017 Resolved
Renew retro-reflective tape on 17 adult and 07 child size PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 25 May 2017 Resolved
Provide current deviation card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 May 2017 Resolved
Conduct extermination on roaches in the PFD lockers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 May 2017 Resolved
Exercise dogs on forward damper IWO the anchor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 25 May 2017 Resolved
Replace missing SFP insulation on aft bulkhead in main deck stair towers, port & starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 May 2017 Resolved
Prove proper operation of FSD #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 May 2017 Resolved
Repair handle to allow egress from FSD #3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 May 2017 Resolved
Conduct verification of all electrical distribution panels to ensure labeling is accurately reflects the installed circuit breakers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 27 June 2017
Resolution: corrected
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 May 2017 Resolved
Prove proper operation of fire damper #1, panel 5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Conductor
Issued 25 May 2017 Resolved
Repair electrical connections for stbd side mooring capstan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 25 May 2017 Resolved
Renew screen on galley natural vent on 01 deck aft of galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 25 May 2017 Resolved
Install GFCI receptacles as needed in galley.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Fire Fighting › Structural - A Class Divisions › Windows
Issued 25 May 2017 Resolved
Reinstall missing SFP insulation for galley ventilation trunk on fwd side of galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 9 June 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 May 2017 Resolved
Repair leak to #3 SSG raw water piping.
Condition: Improper/Lack of Maintenance
Due 25 May 2017
Resolved 25 May 2017
Communications › Public Address System › Loudspeaker
Issued 29 March 2017 Resolved
All public address speakers below the main deck were found inoperable.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Resolution: speakers repaired and tested.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 29 March 2017 Resolved
Determine cause and repair jacket water leak to the #1 MDE.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Resolution: corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 29 March 2017 Resolved
Repair hydraulic leak on the #3 MDE PTO hydraulic hose.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Resolution: corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 March 2017 Resolved
Repair starboard engine room CO2 local control cover that is currently unable to be opened by hand.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 30 March 2017
Resolution: corrected
Electrical › Electrical Distribution System (service) › Cable
Issued 29 March 2017 Resolved
Remove dead end battery cables from the #1 GENSET batteries.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 March 2017 Resolved
Repair extinguished or damaged e-lights in the surveillance room, security office, and light #'s 28 & 31.
Due 29 March 2017
Resolved 30 March 2017
Resolution: corrected
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 March 2017 Resolved
Repair A-class door/frame/latch assembly at the switchboard room.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: cleared
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2017 Resolved
Inspect hull plating behind damaged section of rub rail (stbd side of vessel approx amidships) and provide repair plan if applicable.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 29 March 2017 Resolved
Remove storage and perform housekeeping in switchboard room.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 5 April 2017
Resolution: cleared
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Repair chaffed wire for high water level sensor in port fwd bow thruster space.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 March 2017 Resolved
Perform housekeeping in slot service room, remove items blocking egress and signage for fire damper.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: cleared
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 March 2017 Resolved
Properly secure port fwd hot water heater.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Properly seal wire penetration in the aft bulkhead of the port hot water heater room.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 March 2017 Resolved
Replace all wing nuts used on starting batteries (MDE/SSDG) with proper nuts.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: cleared
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 29 March 2017 Resolved
Replace chaffed hydraulic hose on the #3 MDE.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 29 March 2017 Resolved
Repair jacket water leak at hose assembly on the #2 MDE.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: cleared
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 March 2017 Resolved
Repair door lock assembly on the security office door.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: cleared
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Remove extension cords in security room.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: cleared
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 29 March 2017 Resolved
Properly label the manual ventilation damper lever located outside the male head port side engineering passageway.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 March 2017 Resolved
Revise location/wording of CO2 instructions in the CO2 room.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: corrected
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 29 March 2017 Resolved
Ensure all ID placards and service records are filled out for he IBA's.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 March 2017 Resolved
Prove proper operation of the FSD located on the O2 deck, starboard side fwd.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 29 March 2017 Resolved
Remove moldy carpet from the shower room located on the 02 deck starboard side fwd.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 April 2017
Resolution: corrected
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 29 March 2017 Resolved
Renew wasted AC ventilation trunk in AC room on the 02 deck fwd.
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 5 April 2017
Resolution: corrected
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 29 March 2017 Resolved
Renew safety relief valve for hot water heater on the aft deck.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Lifesaving › Rescue Boat › Construction
Issued 29 March 2017 Resolved
Provide repair proposal for the rescue boat damage and wastage and outfit rescue boat with required equipment.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 17 April 2017
Resolution: corrected
Engineering › Steering Gear System › Actuator
Issued 29 March 2017 Resolved
Properly repair and test steering alarm system and prove proper operation prior to carriage of passengers.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 31 March 2017
Resolution: corrected
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 March 2017 Resolved
Install door handle on the inside door to the engineers office.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Resolution: corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Provide inspection report from a licensed electrician of a detailed steering alarm/control system for port and stbd steering gears and test of alarms.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Identify purpose and either reconnect or remove wiring labeled "fire sensor" at the #1 SSDG.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 21 April 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Remove or properly secure abandoned wiring at the #1 SSDG.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Identify source of power and properly secure or remove 24 VDC wire previously being used to supply the steering alarm system.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 21 April 2017
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 12 December 2016 Resolved
Remove wire penetration through elevator shaft bulkhead for sump pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 30 December 2016
Resolution: Wire was removed and the BLKD penetration was sealed.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 December 2016 Resolved
Make MMSI number operable within VHF-DSC. 47 CFR 80.905
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 27 January 2017
Resolution: Cleared
Fire Fighting › Grease Extraction Hood › General
Issued 12 December 2016 Resolved
Make galley vent hood system operable as reflected on fire control plan. 46 CFR 118.425
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 27 January 2017
Resolution: Corrected
Electrical › Electric Generation Source (service) › Generator
Issued 22 September 2016 Resolved
Prove proper operation of generator #2 to attending marine inspector. Provide technician report once repairs are completed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 30 September 2016
Resolution: GEN 2 was tested satisfactorily.
Stability › Watertight Integrity › General
Issued 29 August 2016 Resolved
Properly repair exhaust piping on Generator Set #2. Pipe is leaking water at bulkhead penetration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2016
Resolved 30 August 2016
Resolution: The exhaust piping was repaired by welding, to the satisfaction of the attending MI. No leaks were detected.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 29 August 2016 Resolved
Ensure proper structural fire protection is installed for through bulkhead penetrations of wire in the switchboard room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 6 September 2016
Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 29 August 2016 Resolved
Ensure pipe in forward port space (above pontoon access ports) is 100% welded on both sides of the bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 6 September 2016
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 August 2016 Resolved
Properly cover the hole in the switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 30 August 2016
Resolution: The hole was properly repaired to the satisfaction of the attending MI.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 29 August 2016 Resolved
Prove proper operation of main propulsion engine #4 to attending MI proper to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 August 2016
Resolution: The head, piston and cylinder liners were replaced. Conducted sea trails to the satisfaction of the attending MI.
Electrical › Electric Generation Source (service) › Generator
Issued 7 August 2016 Resolved
Generator #2 shutdown due to high J.W. temp while vessel was underway with passengers on board. Vessel lost power for approximately 5 seconds before generator #3 could assist with load. Crew replaced temp probe in kind.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 7 August 2016
Resolution: Corrected on the Spot. Proper operation of all three generators tested in attendance of MI and IO.
Electrical › Electric Generation Source (service) › Generator
Issued 5 August 2016 Resolved
Generator #3 failed to start at the dock due to remote E. Stop shutdown on deep sea control system. E. Stop was not engaged. Parameters reset on control module.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: Corrected on the Spot. Generator tested with MI attendance.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 13 May 2016 Resolved
Provide Tech report for generator #3 due to crew noticing strange noise from engine side.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 16 August 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 May 2016 Resolved
Repair leaking raw water intake pipe in port side MDE room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 11 May 2016
Resolution: New pipe fabricated and installed.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2016 Resolved
Correct dead end wiring found above stbd side air receiver in port gen room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 May 2016 Resolved
Repair broken pipe brackets (on 2 pipes) found in port side MDE room under air receivers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 9 May 2016 Resolved
Prove proper operation of rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 11 May 2016
Resolution: Witnessed proper operation of rescue boat.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 9 May 2016 Resolved
Prove proper function and accuracy of the fire detection system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 10 May 2016
Resolution: SOTEC Fire Service completed full system calibration. MI's spot checked accuracy of detectors/panel in each space on board vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 May 2016 Resolved
Complete hydrostatic testing of all portable CO2 fire extinguishers. (>5 yrs)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 10 May 2016
Resolution: SOTEC fire service provided 14 "loaners" and remove 14 overdue extinguishers for hydro testing.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 9 May 2016 Resolved
Repair starboard steering gear grounding strap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Cleared by attending MI.
Electrical › Electric Supply System (service) › Cable
Issued 9 May 2016 Resolved
Correct the following: 1-remove extension cord in port MDE room 2-remove extension cord in galley going into ovrhd 3-correct wiring at fire detector 23 4-properly mount jboxes above wire runs in stbd gen room and stbd crew passage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 24 May 2016
Resolution: Cleared by attending MI.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 May 2016 Resolved
Remove damaged portable electrical fan in stbd gen room (exposed rotating parts).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 May 2016 Resolved
Label breakers #21 & #22 for panel #54 on deck 02.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 9 May 2016 Resolved
Replace outlet cover on deck 01 at center pillar and deck 02 aft/stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Corrected on the spot.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 May 2016 Resolved
Replace lamp on emergency light L2-5 #9.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 May 2016 Resolved
Replace 66 lifejackets improperly stowed on upper deck port/stbd sides as indicated on plan.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Corrected on the spot.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 May 2016 Resolved
Prove accuracy of current fire control plan. Update as needed and submit for approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Plan approved and verified by attending MI.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 May 2016 Resolved
Ensure proper SFP boundary in place between elevator control space and main casino space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Cleared by attending MI.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 May 2016 Resolved
Repair fire damper handle forward of stbd reefer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 May 2016 Resolved
Provide annual servicing reports for fire fighting appliances.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 11 May 2016
Resolution: Reports reviewed by MI.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 9 May 2016 Resolved
Provide annual life saving appliances servicing report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 11 May 2016
Resolution: Reports reviewed by MI.
Lifesaving › Rescue Boat › Construction
Issued 9 May 2016 Resolved
Repair rescue boat nav light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Cleared by attending MI.
Navigation › Piloting/Steering › Marine Charts
Issued 9 May 2016 Resolved
Provide up to date nav charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Cleared by attending MI.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 9 May 2016 Resolved
Identify/repair leakage from both main diesel engine wet exhaust system on MDE 2 and 3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Engineering › Steering Gear System › Valve
Issued 9 May 2016 Resolved
Identify/repair leakage from both steering gear hydraulic fluid tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Engineering › Lubricating Oil Service System › Flange
Issued 9 May 2016 Resolved
Replace threaded bolt (cap) for lube oil tank outlet in STBD side generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Cleared by attending MI.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 May 2016 Resolved
Clean containment under each shaft packing gland and debris/oil from each machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 9 May 2016 Resolved
Repair pump/piping on sludge removal system, or request approval for new system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 9 May 2016 Resolved
Repair/replace gasket material on doors to port generator room and starboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 May 2016 Resolved
Replace lagging on engine exhaust system as needed. Sections missing or in disrepair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Electrical › Electric Generation Source (emergency) › Generator
Issued 9 May 2016 Resolved
Test reverse power relay and generator alarms with marine inspector and tech if needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Cleared by attending MI.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 1 March 2016 Resolved
Ensure VHF-DSC is connected to GPS
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 14 March 2016
Resolution: Radio was connected to GPS.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 1 March 2016 Resolved
Replace fire protection on valve near MDE #4 2nd aft from fire station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Insulation was replaced/repaired.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 1 March 2016 Resolved
Replace clamp raw water pump MDE #4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Hose clamp was installed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 March 2016 Resolved
Cover holes in switchboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Vessel crew covered holes.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 March 2016 Resolved
Repack wire penetrations above both doors leading into the chill water room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Wire penetrations have been re-packed.
Construction/Loadline › Penetrations › Valve Flange
Issued 1 March 2016 Resolved
Clean and find source of salt buildup on check valve fwd of chill room by ladder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Check valve has been repaired and cleaned.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 March 2016 Resolved
Repack overhead wire penetrations in void #1 stbd
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Wire penetration has been re-packed.
Stability › Watertight Integrity › General
Issued 1 March 2016 Resolved
Replace missing screw in bow thruster stbd cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Screw has been repalced.
Electrical › Electric Generation Source (service) › Generator
Issued 5 February 2016 Resolved
Prove proper operation of #4 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 11 February 2016
Resolution: Installed new fuel magnetic particle pickup.
Engineering › Gasoline Engine (auxiliary) › Piston (4 cycle)
Issued 3 January 2016 Resolved
Prove proper operation of #1 generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 4 November 2020
Resolution: Administratively cleared to remove from overdue deficiency log.

Recorded names · 4

MAX I (2002), ATLANTIC (2004), AQUASINO (2008–2013), VICTORY II (2014–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.