← All vessels
VAGABOND
VAGABOND is a 1981 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2017, most recently in July 2026, along with 24 deficiencies.
Records from 2017 to 2026. Most recent: inspection, 27 July 2026.
- Built
- 1981
- Last inspected
- 27 July 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
634688
WDL8266
196417
Flag
UNITED STATES
Maury page id
psix-196417
Inspections, by type
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)41.7 ft × 13.3 ft × 4.1 ft
Registered tonnagegross 15 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESTER · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKENT ISLAND, MD
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 28 July 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
27 July 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8447847
4 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8308155
22 October 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8257061
11 August 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8207443
15 October 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8019252
15 August 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7981651
18 July 2024
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7954877
23 April 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7899910
17 January 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7851896
21 December 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7844736
13 November 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7824109
14 November 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7598374
12 January 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7379006
11 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7378368
26 October 2020
Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7084372
26 August 2020
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7050091
27 August 2017
Type not recorded
No type recorded · Station Annapolis · USCG East District (CGD-E) · Activity 6256912
Deficiency record · 24
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed the port m/e propeller shaft seal leaking an excessive amount of water.
46CFR176.830
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). The forward bilge pump suction was weak and insufficient.
46CFR182.520
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2025
Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The fuel fill piping was not grounded/bonded.
46CFR182.445(g)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the [name withheld] of the portable fire extinguishers were mounted.
46CFR181.520
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 August 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The life float had extreme delamination of the outer layer and is no longer serviceable. Operations are restricted to warm water months only 15 MAY-31 OCT.
46CFR176.808(b)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 July 2024
Resolved
11127 - The float-free link required by § 180.130(a)(1) must be of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. The float free link on the vessel currently is for 6-10 person life floats and the life float is certified for 12 persons.
46 CFR 180.137
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 July 2024
Resolved
11127 - Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The life float only had one paddle.
46 CFR 180.175(d)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2024
Resolved
09209 - Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. There is a wire bundle on the outboard side of the starboard engine that has exposed wires.
46 CFR 183.200(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024
Resolved
13199 - Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The fuel shutoff markings were faded and illegible.
46 CFR 185.608
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 July 2024
Resolved
11127 - Buoyant apparatus with plastic foam buoyancy must have a plastic foam body with an external protective covering. The protective covering on the life float is damaged and needs to be repaired.
46 CFR 180.200(a)(2)
46 CFR 160.010-5(a)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 November 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. STBD engine did not secure when testing the system.
46CFR181.420
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Fire buckets onboard were 5gal, and not in serviceable condition.
46CFR181.610
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 November 2023
Resolved
In addition to meeting § 180.130, each life float and buoyant apparatus must be stowed as required under this section, Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant; Secured to the painter at one end and to the vessel on the other end. Life float does not have a painter line install.
46CFR180.137
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 13 November 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing device onboard was expired.
46CFR4.06-15
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 October 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury.
Stbd rudder packing leaking and not maintaining suitable watertight integrity for the protection of the vessel.
46 CFR 182.100
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2020
Resolved
Portable fire extinguishers in the vicinity of the machinery space must have a minimum rating of 40-B:C. A 40-B:C portable fire extinguisher, indepedant of the operating station and accomodation station extinguishers, was not available.
46 CFR 181.500
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2020
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. The life jackets were not marked with the vessel's name.
46 CFR 185.604
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 October 2020
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by Federal Communications Commission, as set for the in 47 CFR part 80. Vessel did not have required FCC Station License, FCC Safety Radiotelephony Certificate, and FCC Marine Radio Operator Permit.
46 CFR 184.502
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2020
Resolved
The number and identification of adult or child life jackets must be marked in clearly legible letters and numbers on each container for life jackets. Adult and child life jacket storage in accommodation was not marked.
46 CFR 185.604(f)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 October 2020
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Flares were not stored in a bright colored, watertight container, marked "DISTRESS SIGNALS".
46 CFR 185.614
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 October 2020
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel did not have portable lights.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 October 2020
Resolved
One or more placards depicting garbage discharge prohibitions in navigable waters of the United States must be displayed in prominent locations and in sufficient numbers so that they can be read by crew and passengers. Vessel did not have garbage discharge prohibition placards posted.
33 CFR 151.59
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Remote fuel shutoff stations are not marked.
46 CFR 185.608
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Installed Racor fuel filters are not fitted with required flame shield.
46 CFR 182.458(b)(6)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.