Records from 1995 to 2026. Most recent: inspection, 31 March 2026.
Documentation record
Registered dimensions (L × B × D)54.3 ft × 22.0 ft × 7.6 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRUMPLERS SHPBLDG CO INC · ORANGE, TX, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCOVINGTON, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
31 March 2026
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8340188
25 March 2025
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8099798
20 March 2024
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7866032
7 April 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7664678
21 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7655391
11 February 2022
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7399902
4 March 2020
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6920733
9 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6684943
24 January 2018
MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6354399
19 March 2014
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4828908
9 April 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4565457
25 March 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4555943
15 December 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4504129
24 June 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4056360
19 April 2011
Deficiency Check · Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3990102
6 March 2001
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 290278
8 July 1998
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 417870
26 September 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 408446
29 August 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 8524
29 August 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 223396
16 June 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 406593
12 November 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 188750
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2023
Resolved
TBD shaft slid back from coupling disengaging the shaft from the reduction gear.
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel is restricted from pushing cargo until repairs are complete.
Prove proper repair to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2023
Resolved 10 April 2023
Resolution: MI attended vessel Hebron KY, got underway for test of shaft coupling with satisfcatory results.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2022
Resolved
Fixed fire pump would not produce required amount of pressure due to silt and mud in the sea chest. A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants at 50 psi. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2022
Resolution: Fire pump satisfactory operational
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 February 2022
Resolved
Vessel name in AIS was displaying Joshua and not the Bromley. The following vessels must have on board a properly installed, operational Coast Guard type approved AIS Class A device. Make corrections to AIS to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
Resolution: AIS displayed Bromely as vessel name.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Electrical panel in engine room does not have labeling of breakers. Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Label breakers in electrical panel to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
Resolution: Received objective evidence electrical panel was labled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 February 2022
Resolved
Starboard main engine jacket water gauge and port main engine RPM gauge in the engine room are not operable. Alarm panel on bridge is not legible and partially hidden behind steering sticks. Towing vessels must have Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (1) Main engine low lubricating oil pressure; (2) Main engine high cooling water temperature. Make repairs to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
Resolution: Guages are in working order.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 February 2022
Resolved
Guard for shafts are not bolted down and bracket for guard on port generator is broke. An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Make repairs to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
Resolution: Received objective evidence the guard was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 February 2022
Resolved
Shaft packing have excessive leaking. Machinery must be maintained to provide safe operation of the towing vessel. Make repairs to the satisfaction of the attending Coast Guard Marine Inspector
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
Resolution: No leaks found on shaft.
Electrical
Issued 6 March 2001
Resolved
Protective light covers were missing.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Electrical
Issued 6 March 2001
Resolved
Exposed and dead end wiring in storage area under pilot house has been repaired.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Accommodation/Occupational Safety
Issued 6 March 2001
Resolved
MSD was used but not flushed creating a very unpleasent working environment. MSD is now in proper working condition.
Condition: Unknown
Due 8 April 2001
Resolved 21 May 2001
Engineering
Issued 6 March 2001
Resolved
Flame screen on the aft stbd side was torn. Captain replaced the flame screen prior to Coast Guard personnel departing the vessel.
Condition: Unknown
Due 8 March 2001
Resolved 21 May 2001
Navigation
Issued 16 June 1997
Resolved
VESSEL WAS MISSING IT'S MASTHEAD AND STERN LIGHTS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 16 June 1997
Resolved
VESSEL WAS MISSING IT'S MAGNETIC COMPASS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 16 June 1997
Resolved
VESSEL'S OFFICIAL WASN'T PERMANENTLY MARKED ON THE HULL OR STRUCTURAL MEMBER OF THE HULL.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Lifesaving
Issued 16 June 1997
Resolved
VESSEL'S TYPE I PFD'S WERE NOT READILY ACCESSIBLE.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 16 June 1997
Resolved
VESSEL DIDN'T HAVE RADAR. RADAR IS REQUIRED BY 02AUG97.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Documentation
Issued 16 June 1997
Resolved
VESSEL WAS MISSING MARPOL PLACARD.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997