Records from 2001 to 2007. Most recent: inspection, 15 January 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
15 January 2007
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2913602
4 January 2007
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2847857
9 December 2005
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2551753
6 December 2005
Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2548165
28 October 2005
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2527445
7 June 2005
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2382726
3 January 2005
Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2267735
9 March 2004
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2021269
16 December 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1954995
6 December 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1733190
4 December 2002
Re-Inspection · Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1713205
13 May 2002
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1616105
28 November 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456040
5 June 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066848
Stability › Severe Wind/Roll › General
Issued 28 October 2005
No resolution recorded
Prior to one (1) week before the stability test required to increase passengers beyond 25, the vessel must be weighed in a fully outfitted condition with all tanks minimum ¾ full. Provide this office with a certified weight certificate with a least 4 digital or conventional photographs of the vessel with the date imbedded in the photo bearing the same date as the certified weight certificate.
Due 26 December 2005 — due date passed with no resolution recorded
Resolution: Requirement removed as per CID
Stability › Severe Wind/Roll › General
Issued 28 October 2005
Resolved
Prior to or at the vessel's next annual insp or hull exam, whichever occurs first, the vsl must undergo a simplified stability proof test in accordance w/ 46 CFR 178.340 in the presence of a CG Marine Inspector to determine the number of passengers permitted. Until a simplified stability proof test is performed, the vsl is restricted to carrying twenty-five (25) passengers and two (2) crewmembers.
Due 26 December 2005
Resolved 6 December 2005
Resolution: Performed pontoon stability test
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 January 2005
Resolved
PROVIDE CURRENT ASPIRIN AND EYE WASH FOR 1ST AID KIT.
Due 3 February 2005
Resolved 7 June 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 January 2005
Resolved
SERVICE AFT FIRE EXTINGUISHER.
Due 3 February 2005
Resolved 7 June 2005
Engineering › Bilge Water Management System
Issued 16 December 2003
Resolved
Provide a portable bilge pump onboard vessel. LEGACY COMPONENT DESC: Pump
Due 1 January 2004
Resolved 6 January 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 December 2003
Resolved
Provide a complete first aid kit onboard. LEGACY COMPONENT DESC: Medicine Chest
Due 1 January 2004
Resolved 6 January 2004
Operations/Management › Drills/Instruction
Issued 16 December 2003
Resolved
Conduct emergency drills monthly, fax copy of log to MSD FT Myers for JAN-MAR 2004. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 31 March 2004
Resolved 9 March 2004
Navigation › Collision/Grounding Avoidance
Issued 4 December 2002
Resolved
Demonstate proper operation of navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 6 December 2002
Resolution: Owner repaired nav lights.
Lifesaving
Issued 28 November 2001
Resolved
CONDUCT SAFETY ORIENTATION IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 15 December 2001
Resolved 15 December 2002
Documentation
Issued 28 November 2001
Resolved
PROVIDE LOG BOOK FOR RECORDING DRILLS.
Condition: Unknown
Due 15 December 2001
Resolved 15 December 2002
Engineering
Issued 28 November 2001
Resolved
REPAIR REPLACE STARBOARD EMERGENCY FUEL STOP.
Condition: Unknown
Due 15 December 2001
Resolved 15 December 2001
Engineering
Issued 28 November 2001
Resolved
REPLACE FUEL VENT SCREEN STARBOARD FUEL TANK VENT PIPE.
Condition: Unknown
Due 15 December 2001
Resolved 15 December 2001
Navigation
Issued 28 November 2001
Resolved
PROVIDE NAVIGATION CHART OF AREA, COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 15 December 2001
Resolved 15 December 2001
Lifesaving
Issued 28 November 2001
Resolved
CONDUCT MAN OVERBOARD DRILLS & FIRE DRILLS.
Condition: Unknown
Due 15 December 2001
Resolved 15 December 2001