MAURY USCG vessel records Sign in
← All vessels

ZOI

ZOI is a 2000 freight ship. The Coast Guard has recorded 33 inspections since 2002, most recently in June 2022, along with 12 deficiencies and 7 operational controls.

Records from 2002 to 2022. Most recent: inspection, 24 June 2022.

Built
2000
Last inspected
24 June 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9216987 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
GREECE
—
Maury page id
psix-19686

Inspections, by type

…with no type recorded9
Years with a record 16 calendar years (2002–2022)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it68121 - Dead Weight, Ton
35536 - Displacement, Ton
65059 - Regulatory (Subpart C or D), Gross Ton
35536 - Regulatory (Subpart C or D), Net Ton
65059 - Convention (Subpart B), Gross Ton
35536 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

24 June 2022 PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7482762
10 November 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7344745
10 July 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7002565
6 May 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6949405
9 March 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6923238
25 September 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6820719
18 August 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6786677
14 August 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6783573
28 July 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6493037
30 January 2018 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6347438
24 January 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6341608
16 January 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6338321
29 June 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6188960
19 June 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6180061
18 March 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5836121
5 January 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5790945
24 July 2015 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5190752
26 August 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4124935
5 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4070474
4 July 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4068614
6 February 2011 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3940140
15 December 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3910945
14 December 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3910512
1 February 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3403365
22 January 2009 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3398089
22 January 2009 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3398185
22 April 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3188916
2 April 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2899462
24 May 2006 Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2659517
20 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2654398
3 December 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2545271
8 December 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1716046
6 January 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1475422

Deficiency record · 12

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 14 August 2019 Resolved
15104-safety management systems (ISM)- The company should clearly define and document the master's responsibility with regard to; implementing the safety and environmental-protection policy of the company PSCO observed a hot work area that was created by the crew in forecastle. [name withheld] stated "it was being used to create repair pieces for ventilation." PSCO observed 3 Oxygen and 1 Acetylene bottles stored in forecastle in vicinity of the hot work area. Reviewed the procedures for hot work permits issued for the hot work being conducted in forecastle. Additionally, the vessel's SMS procedures states that hot work is prohibited within 15 meters of dangerous goods. During multiple voyages the vessel had dangerous goods stowed in Bay 01 and Bay 03. Vessel is prohibited from conducting hot work in forecastle until company provides corrective action plan with concurrence with administration approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 25 September 2019
Resolution: Class report, hot work permit, and risk assessment documentation provided clearing deficiency
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 June 2017 Resolved
The Company should establish procedures to ensure that the ship is maintained I.A.W SMS. PSCO found that Emergency Diesel generator the oil filter had not been Replaced I.A.W. manufacturers specifications and that the preventive maintenance procedures do not address such maintenance. ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 29 June 2017
Resolution: Flag inspector attested to the change of the fuel oil filter I.A.W. manufacturers specifications and provided evidence that chief engineer followed procedures to request update of the ships PMS system.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 5 January 2016 Resolved
THE SEAL BETWEEN THE BOTTOM OF THE ENGINE AND CRANKCASE HOUSING IS LEAKING EXCESSIVE LUBE OIL.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 18 March 2016
Resolution: Class report provided to SECNY.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 5 January 2016 Resolved
THE TURBO CHARGER COOLER ON THE MAIN ENGINE HAS A CONSISTENT FLOW OF OIL LEAKING.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 18 March 2016
Resolution: Class report provided to SECNY.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 December 2010 Resolved
The Radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2010
Resolved 6 February 2011
Resolution: Received documentation from vessel''s classification society via agent attesting to the proper operation of the radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 December 2010 Resolved
Vessel's 3GHz radar is currently not fully functional. SOLAS 2009 CH V Reg 19.2.7.1 Outbound LOD granted.
Action required: 705 - Other - as specified
Due 21 December 2010
Resolved 6 February 2011
Resolution: Received documentation from vessel''s classification society via agent attesting to the proper operation of the rader.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 14 December 2010 Resolved
Vessels officers were not receiving at least 6 consecutive hours of rest every 24 hours. Vessel must submit work rest logs for all officers prior to departure. To the satisfaction of Administration and Coast Guard. STCW V 4.2.5.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2010
Resolution: Received a signed statement certifying that all crew had a minimum of 6 consecurive hours of rest in the last 24 hours.
Fire Fighting › Fire Hoses › Condition
Issued 22 April 2008 Resolved
During testing of the emergency fire pump, 7 hoses produced leaks in the hose when charged. SOLAS Consolidated Chapter II-2 Reg. 4 7.1 To the satisfaction of Class
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2008
Resolved 23 April 2008
Resolution: The Master ordered new replacement fire hoses. The Stork couplings were removed from the failed hoses. The couplings were installed on the new hoses by a shore side contractor. All hoses were hydro tested to the satisfaction of the class surveyor.
Operations/Management › Drills/Instruction › Fire
Issued 22 April 2008 Resolved
The fire drill was not satisfactory and did not demonstrate crew competency when fighting fire aboard ship. The drill was initiated a second time and proved to demonstrate the crews ability to fight fire aboard ship Deficiency Rectified.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 2 August 2017
Resolution: The drill was initiated a second time and proved to demonstrate the crews ability to fight fire aboard ship to the satisfaction of the attending Coast Guard Marine Inspector
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 22 April 2008 Resolved
The Container Guide between 07 - 05 in cargo hold number 6a is bent out of shape preventing proper loading and unloading of containers. Repair to satisfaction of Class
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 May 2008
Resolved 23 April 2008
Resolution: The Identified cell guide has been straighteded adequately to allow the normal discharge and loading of cargo containers. All remaining cargo at the time of the USCG Inspection has been discharged. As per Class report
Navigation › Piloting/Steering
Issued 8 December 2002 Resolved
International Inland Navigation Rules Publication not on board. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2002
Resolution: International/Inland Navigation Rules were verified onboard by ABS Class Society.
Pollution Prevention/Response › Prevention Equipment
Issued 8 December 2002 Resolved
Oily Water Separator Inoperative. All oily waste to be maintained on board until the classification society inspects and signs off on repairs of the oily water separator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 15 - Rectify deficiencies by next port
Resolved 12 December 2002
Resolution: Solenoid valve of overboard discharge valve was inspected by ABS Class Society and found to be satisfactory.

Ownership record