MAURY USCG vessel records Sign in
← All vessels

CYGNUS

CYGNUS is a 1998 freight ship. The Coast Guard has recorded 35 inspections since 2001, most recently in May 2026, along with 13 deficiencies and 9 operational controls.

Records from 2001 to 2026. Most recent: inspection, 4 May 2026.

Built
1998
Last inspected
4 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9197428 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PORTUGAL
—
Maury page id
psix-19689

Inspections, by type

…with no type recorded11
Years with a record 13 calendar years (2001–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3380 - Dead Weight, Metric Ton
2528 - Convention (Subpart B), Gross Ton
1372 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

4 May 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8361266
24 June 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8165920
29 November 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8041162
25 October 2024 ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8024660
19 October 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8021447
30 July 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7969503
16 April 2024 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7895528
16 April 2024 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7896171
22 April 2021 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7178364
30 November 2020 PSC B
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7103385
10 April 2020 COE-Offshore · PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6935907
10 April 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6937856
6 April 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6935800
10 April 2019 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6659027
6 February 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6620124
17 August 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6514074
18 May 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6411824
14 October 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6286898
13 October 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6287400
12 October 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6286229
22 June 2016 Ballast Water Examination · PII Safety Exam · COE-Dockside · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5909036
23 December 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5783866
28 October 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5014267
25 October 2014 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5011785
23 October 2014 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5010742
27 August 2014 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4967291
25 August 2014 PII Safety Exam · COE-Offshore · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4961240
25 August 2014 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4964973
23 August 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4961340
13 May 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4857342
12 March 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4813544
12 March 2014 COE-Offshore
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4814953
2 February 2002 In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1483490
2 November 2001 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 295093
14 March 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 288077

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2026 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-O" class division and be protected by self-closing doors at all levels. PSCO's observed that the self-closing door to the escape trunk in the E/R did not fully close and latch properly. 74 SOLAS (97) II-2/46.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 May 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 June 2025 Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. PSCOs observed 01 smoke detector in the engine room immediately outside of the ECR which did not alarm when tested multiple times. Crew replaced detector and was tested satisfactory. 74SOLAS(97) II-2/13.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 24 June 2025
Resolution: Crew replaced detector and was tested satisfactory.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 30 November 2020 Resolved
Emergency escape ladder door in the engine room was missing a door handle. Chief engineer noted that it was broken.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2021
Resolution: Recieved report, photos and other proper documentation providing information that the door handle had been fixed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 April 2020 Resolved
Doors required to be self-closing shall not b fitted with holdback hooks. Hook was found holding galley door open and a rope was found holding back the self-closing door door between the engine control room and the steering gear room. 74 SOLAS (01) CH II-2/47.10
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2020
Resolved 6 May 2020
Resolution: Recieved class report attesting to rectification and photographic evidence of removal of holdback hooks.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 April 2020 Resolved
Each Liferaft shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code. The hydrostatic release on the starboard liferaft was updide down, preventing the liferaft from floating free. 74 SOLAS (14) CH III / 13.4.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 April 2020
Resolved 10 April 2020
Resolution: Installed the Hydrostatic release correctly.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 18 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The winch control was found to be inoperable, limiting anchor operations and posing a risk to the crew. 74SOLAS(14) I/11 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 19 August 2018
Resolution: Crew recieved parts and repaired Winch
Communications › Visual Communication › Signalling Lamp
Issued 18 May 2018 Resolved
All ships of 150 gross tonnage and upwards shall be fitted with a daylight signaling lamp or other means to communicate by light during day and night using an energy source of electrical power not only dependent upon the ship's power supply. Vessel is missing independent power supply for its daylight signaling lamp. 74SOLAS(14) V/19.2.2.2.2 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 19 August 2018
Resolution: Day light signaling lamp provided with independent source of supply
Fire Fighting › Combustible Materials › Stowage
Issued 18 May 2018 Resolved
Ignition sources shall be restricted. Cardboard was used around the flywheel to stop the spread of oil presenting itself as a source of ignition. 74SOLAS(14) II-2/4.1.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 May 2018
Resolved 18 May 2018
Resolution: The Chief Engineer removed the cardboard from around the flywheel
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 18 May 2018 Resolved
Oil fuel pipes and their valves and fittings shall be of steel or other approved material. A non-fire resisting type soft patch, not approved by the administration, was found on the lube oil piping between the lube oil storage tank and the MDE. 74SOLAS(01) II-2/15.2.8 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 19 August 2018
Resolution: Pipe welded to fix leak and support added to prevent further issues with piping.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 May 2018 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Rope was found holding back the self-closing door between the engine control room and the steering gear room. 74SOLAS(01) II-2/47.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 May 2018
Resolved 18 May 2018
Resolution: The rope was removed which allowed the door to be self-closing.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 18 May 2018 Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The deck line and the hull are both green, thus no contrasting in color. ILLC I/8 40c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 August 2018
Resolution: load line has been painted white to contrast with the hull.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 18 May 2018 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be to ensure the safety of the ship and persons onboard. Oil was observed to be able to weep out of the flywheel shaft unobstructed. 74SOLAS(01) II-2/15.2 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 19 August 2018
Resolution: metal sheeting added to flywheel cover and the source of the weeping oil remedied
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 25 August 2014 Resolved
01 A main source of electrical power shall consist of at least two generator sets. Diesel Generator No.2 is disassembled due to High temp alarm. High temp was caused by steel shavings in the oil of cylinders 4,5, and 6. Technician onboard conducting repairs during PSC Examination. 74 Solas (2004 Cons Ed.) 11-1/41.1.1 (17ac)
Action required: 705 - Other - as specified
Due 2 September 2014
Resolved 28 October 2014
Resolution: Verified Proper operation of Generator, on off shore boarding and Class Report Attached attest to proper operation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.