MAURY USCG vessel records Sign in
← All vessels

KNOCK

KNOCK is a 1999 freight ship. The Coast Guard has recorded 20 inspections since 2001, most recently in July 2012, along with 12 deficiencies and 7 operational controls.

Records from 2001 to 2012. Most recent: inspection, 31 July 2012.

Built
1999
Last inspected
31 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208681 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-19690

Inspections, by type

…with no type recorded13
Years with a record 9 calendar years (2001–2012)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4450 - Convention (Subpart B), Gross Ton
5603 - Dead Weight, Ton
2965 - Displacement, Ton
2141 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

31 July 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4413694
30 July 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4393842
18 July 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4085611
1 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3672523
31 January 2010 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3672397
22 July 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3542378
16 July 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3536486
19 March 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3167614
9 February 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3144642
20 April 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2911884
19 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2910756
9 March 2007 ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2886188
10 August 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2743148
7 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2738924
8 March 2006 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2598423
23 April 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1608373
22 April 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1620266
3 January 2002 Deficiency Check · Passenger/Freight Vessel Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1478972
9 August 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 292569
6 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 286779

Deficiency record · 12

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 July 2012 Resolved
MARPOL Annex I/Reg 14.7. Oil filtering equipment shall be such as will ensure that any discharge of oil will be automatically stopped when exceeding 15 ppm. Vessel OWS is not functional
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2012
Resolution: Class Society has issued an Interim IOPP Certificate valid until 31 August, 2012. The defective oil filtering equipment shall be repaired or replaced no later the 31 August, 2012.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 30 July 2012 Resolved
33CFR155.820 (b) The vessel operator shall keep a written record of the day and result of the most recent test and inspection of transfer pipe system. Vessel bunker test records were not available,
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Resolved 31 July 2012
Resolution: Vessel tested bunker lines IAW 33CFR156.17(c)4 and recorded test IAW 33CFR155.820(b).
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 July 2011 Resolved
Guard rails fitted on freeboard deck should have at least three courses. Starboard side deck railing is missing courses in several spots and is broken in other areas affecting safety of transit. ICLL 88 reg 25.3.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2011
Stability › Weathertight Integrity › General
Issued 18 July 2011 Resolved
Means for securing doors weathertight. CO2 room door does not maintain weathertight integrity. ICLL 88 reg 12.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2011
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 18 July 2011 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. All lifesaving appliances prescribed in this part shall be fitted with retroreflective material. Life ring on the bow does not have retroreflective material to assist with detection. 74 SOLAS 2004 cons CHIII red 34. LSA 1.2.2.7
Action required: 705 - Other - as specified
Due 1 August 2011
Resolved 8 August 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 18 July 2011 Resolved
All electrical appliances shall be installed not to cause injury when handled or touched. Light fixtures on the liferaft deck and emergency generator room found fractured. 74 SOLAS 04 cons CHII-I reg 45.1.3
Action required: 705 - Other - as specified
Due 17 August 2011
Resolved 18 July 2011
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 16 July 2009 Resolved
The vessel submitted an NOA prior to departing Freeport, Bahamas, at 0355 on 16JUL09 and listed their arrival time as 1200 on 16JUL09. 33CFR160.212 states that if a vessel's voyage time is less than 96 hours an ANOA must be submitted before departure but at least 24 hours before entering port or place of destination.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2009
Resolution: Vessel was ordered depart US waters and remain outside US waters until 24 hour time requirement. Vessel complied with this order. Rcvd LOU.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 9 March 2007 Resolved
02 firefighting outfits did not meet the requirements of SOLAS. One suit did not have adequate thermal protection, the second was worn and needs to be replaced all together.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2007
Resolution: Received faxed copy of the purchase of 02 firefighting outfits.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 March 2007 Resolved
Emergency Generator fuel tank did not have a proper working emergency shut-off valve.
Action required: 705 - Other - as specified
Due 16 March 2007
Resolved 9 March 2007
Resolution: Completed repair, corrected on the spot.
Fire Fighting › Firemans Outfit
Issued 3 January 2002 Resolved
LIFELINES HAD NO CLIPS AND WERE NOT SOLAS 74/78 COMPLIANT. LEGACY COMPONENT DESC: Lifeline
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2002
Resolution: New lifelines purchased.
Fire Fighting › Firemans Outfit
Issued 3 January 2002 Resolved
ALUMINIZING MATERIAL ON PROTECTIVE CLOTHING HAD WORN AWAY IN SEVERAL LOCATIONS, CAUSING THE CLOTHING TO PROVIDE UNSATISFACTORY PROTECTION. LEGACY COMPONENT DESC: Protective Clothing
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2002
Resolution: New firesuits purchased.
Fire Fighting › Miscellaneous Items
Issued 3 January 2002 Resolved
SOLAS II-2 REGULATION 13.1.1, ALARM LIGHTS ON THE BRIDGE WERE INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2002
Resolution: Repairs completed, alarm lights work properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.