MAURY USCG vessel records Sign in
← All vessels

EMMA G

EMMA G is a 1980 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1997, most recently in July 2008, along with 24 deficiencies — 2 with no resolution recorded —.

Records from 1997 to 2008. Most recent: inspection, 8 July 2008.

Built
1980
Last inspected
8 July 2008
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA7019
196995
Flag
UNITED STATES
366838740 (licence lapsed)
Maury page id
psix-196995

Inspections, by type

…past their stated due date2
Years with a record 12 calendar years (1997–2008)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.1 ft × 12.7 ft × 3.2 ft
Registered tonnagegross 14 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE MARINE INDUST. · TRAPPE, MD, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOLOMONS, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA7019MMSI 366838740 · expired · compulsorily equipped · granted 13 February 2002, cancelled 14 April 2012
WCX5416MMSI not assigned · expired · compulsorily equipped · granted 16 June 1997, cancelled 19 August 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

8 July 2008 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3261465
27 June 2007 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2975738
6 June 2007 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2953194
22 August 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2754984
12 May 2005 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2352923
17 August 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2169808
16 March 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2025756
28 August 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1889934
9 April 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1603032
5 April 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1602463
5 March 2002 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1491171
20 August 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1453931
4 April 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1061536
24 May 2000 COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1365772
24 June 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 777719
27 May 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 803257
7 April 1999 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 786679
2 September 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 797227
11 June 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1127342
2 June 1997 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1460143
10 April 1997 Plan Review "T" Boat · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1460142

Deficiency record · 24

Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 27 June 2007 No resolution recorded
sensor in engine compartment does not meet NTSB safety recommendation M-06-11.
Action required: 705 - Other - as specified
Due 1 April 2008 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 June 2007 No resolution recorded
Did not make vessel available for dry dock examination and internal structural examination before March 31, 2007
Due 6 June 2007 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 22 August 2006 Resolved
Provide copy of MIS report
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2006
Resolved 25 August 2006
Resolution: Recieved fax copy of proof of enrollment.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 August 2006 Resolved
Show proof of servicing of all fire protection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2006
Resolved 25 August 2006
Resolution: Recieved faxed copy of service report.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 22 August 2006 Resolved
Move weak link to interior of painter container.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2006
Resolved 25 August 2006
Resolution: resolved via phone con with owner.
Documentation › Certificates/Documents › FCC SSL
Issued 17 August 2004 Resolved
Provide valid FCC Safety certificate.
Action required: 705 - Other - as specified
Due 17 September 2004
Resolved 16 September 2004
Documentation › Manuals/Policy Documentation
Issued 28 August 2003 Resolved
Provide up to date light list for area of operation.
Due 22 September 2003
Resolved 28 August 2003
Resolution: Faxed reciept of purchase of 2003 light list.
Documentation
Issued 20 August 2001 Resolved
PROVIDE A COPY OF THE COASTPILOT.
Condition: Unknown
Due 20 September 2001
Resolved 24 August 2001
Electrical
Issued 20 August 2001 Resolved
PROVIDE COVERS FOR TWO CABIN LIGHTS.
Condition: Unknown
Due 20 September 2001
Resolved 24 August 2001
Engineering
Issued 20 August 2001 Resolved
TIGHTEN SHAFT PACKING.
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 20 August 2001 Resolved
RENEW HIGH WATER ALARM IN BATTERY/ENGINE COMPARTMENT AND LABEL HIGH WATER ALARMS AT OPERATING STATION.
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Construction/Loadline
Issued 20 August 2001 Resolved
MAKE HATCH COVER ON MAIN DECK WATERTIGHT.
Condition: Unknown
Due 20 September 2001
Resolved 24 August 2001
Construction/Loadline
Issued 20 August 2001 Resolved
MAKE COAMING TO CABIN SPACE SIX INCHES.
Condition: Unknown
Due 20 September 2001
Resolved 24 August 2001
Navigation
Issued 20 August 2001 Resolved
RENEW/REPLACE STERN LIGHT.
Condition: Unknown
Due 20 September 2001
Resolved 24 August 2001
Electrical
Issued 24 May 2000 Resolved
PROVIDE COVER ON CABIN LIGHT.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Electrical
Issued 24 May 2000 Resolved
TIGHTEN ALTERNATOR BELTS.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Construction/Loadline
Issued 24 May 2000 Resolved
PLUB AND CAP UNUSED THRU HULL VALVE.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Engineering
Issued 24 May 2000 Resolved
TIGHTEN SEA STRAINER MOUNT.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Engineering
Issued 24 May 2000 Resolved
REPLACE EXHAUST COOLING SUPPLY HOSE.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Construction/Loadline
Issued 27 May 1999 Resolved
PROVIDE HIGH WATER BILGE ALARMS IN SPACES WITH THRU HULL FITTINGS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Engineering
Issued 11 June 1998 Resolved
REMOUNT/FIX SEA STRAINER.
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998
Engineering
Issued 11 June 1998 Resolved
DOUBEL CLAMP FLEXIBLE OTHER END OF EXHAUST HOSE.
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998
Engineering
Issued 11 June 1998 Resolved
DOUBLE CLAMP FLEXIBLE HOSE AT RAW WATER STRAINER.
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998
Engineering
Issued 11 June 1998 Resolved
REWELD SLEEVE ON CAP ON EXHAUST EXPANSION TANK ON ENGINE.
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.