This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
209 - Simplified, Gross Ton
209 - Simplified, Net Ton
Maury page id
psix-19724
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
5 May 2010Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3731703
24 October 2008Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3350935
31 January 2008Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3139630
6 March 2007Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2882608
5 December 2005COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2544267
16 February 2005Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293502
31 March 2004Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2034541
31 January 2004Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2001840
13 May 2003Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1792746
14 May 2002Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1616340
12 January 2001Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361916
Port, Starboard and Centerline navigation light standard shields not matte black in color.
Condition: Improper/Lack of Maintenance
Due 16 February 2005
Resolved 16 February 2005
Resolution: Towing vessel crew repainted navigation light shields.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 16 February 2005Resolved
Five (5) broken welds in cargo tank bulkheads.
Condition: Damaged By Earlier Event
Due 16 February 2005
Resolved 16 February 2005
Resolution: Third-Party welder brought in to repair broken welds.
Navigation › Collision/Grounding Avoidance
Issued 31 March 2004Resolved
Repaint and install port light stanchion. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 31 March 2004
Resolution: Repainted and installed port stachion.
Navigation › Collision/Grounding Avoidance
Issued 31 March 2004Resolved
Provide and install center navigation light stanchion. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 31 March 2004
Resolution: Installed stanchion.
Deck/Cargo › Holds/Tanks
Issued 31 March 2004Resolved
Remove water in all voids. LEGACY COMPONENT DESC: void
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2004
Resolved 31 March 2004
Resolution: Removed water from voids
Communications › Visual Communication
Issued 31 March 2004Resolved
Painted red flag red. LEGACY COMPONENT DESC: Red Warning Signal
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 31 March 2004
Resolution: Painted red flag
Construction/Loadline › Markings
Issued 31 March 2004Resolved
Paint all draft marks LEGACY COMPONENT DESC: Draft Marks/Indicating System
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 31 March 2004
Resolution: Painted draft marks
Documentation › Safety/Response Plans/Programs
Issued 31 March 2004Resolved
Provide updated annual response plan letter. LEGACY COMPONENT DESC: Vessel Response Plan
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 2 April 2004
Resolution: Provided updated response letter.