MAURY USCG vessel records Sign in
← All vessels

POMPANO

POMPANO is a 1981 offshore supply vessel. The Coast Guard has recorded 37 inspections since 1989, most recently in June 2016, along with 14 deficiencies and 1 operational control.

Records from 1989 to 2016. Most recent: inspection, 27 June 2016.

Built
1981
Last inspected
27 June 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8765905 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC4890
197448
Flag
UNITED STATES
366726230, 366947690, 367032410, 367624290 (licence lapsed)
Maury page id
psix-197448

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (1989–2016)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)76.0 ft × 38.0 ft × 7.7 ft
Registered tonnagegross 196 / net 133
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLUE STREAK INDUSTRIES,IN · CHALMETTE, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it196 - Regulatory (Subpart C or D), Gross Ton
133 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH5078MMSI 367624290 · expired · compulsorily equipped · granted 30 May 2014, cancelled 3 August 2024
WDC4890MMSI 367032410 · expired · compulsorily equipped · granted 9 April 2005, cancelled 13 June 2015
WDB7764MMSI 366947690 · expired · compulsorily equipped · granted 14 May 2004, cancelled 19 July 2014
WCW9242MMSI 366726230 · expired · voluntarily equipped · granted 30 October 1996, cancelled 30 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 37

27 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5921145
13 May 2014 MTSA Verification · Examination of Repairs · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4860043
16 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4313312
1 September 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3838693
27 May 2008 Hull Examination · Administrative Inspection · MTSA Verification · Re-Inspection · Examination of Repairs · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3219211
31 May 2007 Ballast Water Examination · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2947238
11 April 2006 MTSA Verification · Hull Examination · COI Inspection · Ballast Water Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2621810
23 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539910
28 March 2005 Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2320974
16 December 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260333
19 August 2004 MTSA Verification · Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2170803
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972259
27 February 2003 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1749937
20 May 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626670
2 March 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443140
9 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804997
6 October 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813467
3 November 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372406
2 July 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421366
4 October 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416384
12 January 1996 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357452
30 November 1995 Damage Survey · Permit to Proceed
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394421
27 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 147781
12 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466401
6 October 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403847
20 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 219981
22 October 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1160903
18 October 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 98459
13 October 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417566
10 May 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827206
3 May 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1147910
16 December 1992 Re-Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463022
14 November 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1311528
31 October 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1004028
4 December 1990 Deficiency Check · Re-Inspection · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1229508
24 August 1990 Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231148
2 November 1989 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912249

Deficiency record · 14

Construction/Loadline › Structures › Superstructure
Issued 23 May 2014 Resolved
Aft cabin support brace was wasted near the top. Shipyard to crop/renew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2014
Resolution: Replaced.
Engineering › Bilge Water Management System › Valve
Issued 23 May 2014 Resolved
Remote operated bilge valves in both engine rooms were inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2014
Resolution: Repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2010 Resolved
Properly secure junction box in port side engine room
Due 8 September 2010
Resolved 1 September 2010
Resolution: Junction box properly secured.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2010 Resolved
Place chaffing gear on hydraulic control lines in port engine room.
Due 8 October 2010
Resolved 1 October 2010
Resolution: Chaffing gear placed on hydraulic control lines
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2010 Resolved
Replace spliced wire with one continuous wire in portside engine room.
Due 1 September 2010
Resolved 1 September 2010
Resolution: Wire replaced.
Construction/Loadline
Issued 22 October 1993 Resolved
MAKE TEMPORARY REPAIRS TO FRACTURES INWAY OF SLOP SHEET IN WAY OF FORWARD RAKE CENTERLINE AND STARBOARD SIDE AS INDICATED.
Condition: Unknown
Due 22 October 1993
Resolved 11 January 1994
Construction/Loadline
Issued 22 October 1993 Resolved
MAKE PERMANENT REPAIRS TO BOW RAKE
Condition: Unknown
Due 22 October 1993
Resolved 11 January 1994
Documentation
Issued 2 November 1989 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989
Documentation
Issued 2 November 1989 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989
Lifesaving
Issued 2 November 1989 Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989
Navigation
Issued 2 November 1989 Resolved
PROVIDE POWER FAILURE ALARM FOR STEERING GEAR (AUDIBLE, VISUAL).
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989
Accommodation/Occupational Safety
Issued 2 November 1989 Resolved
PROVIDE REMOTE SHUT DOWNS FOR VENTILATION SYSTEM.
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989
Fire Fighting
Issued 2 November 1989 Resolved
PROVIDE SMOKE ALARMS FOR BERTHING STATE ROOMS.
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989
Documentation
Issued 2 November 1989 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, FIRE CONTROL PLAN AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 2 November 1989
Resolved 2 November 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.