MAURY USCG vessel records Sign in
← All vessels

RICK STIERWALD ELEVATOR

RICK STIERWALD ELEVATOR is a 1981 offshore supply vessel. The Coast Guard has recorded 15 inspections since 1998, most recently in September 2016, along with 34 deficiencies and 1 operational control.

Records from 1998 to 2016. Most recent: inspection, 23 September 2016.

Built
1981
Last inspected
23 September 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

199444
Flag
UNITED STATES
—
Maury page id
psix-199444

Inspections, by type

Years with a record 13 calendar years (1998–2016)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 90 / net 81
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CARNARVON, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
81 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

23 September 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6007869
30 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5987743
1 October 2015 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5733235
20 July 2015 Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5190107
18 March 2010 Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3725345
10 March 2009 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3430978
14 April 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3183711
9 March 2005 COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2304962
10 February 2004 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2000264
24 February 2003 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1746478
21 May 2002 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1618855
3 January 2001 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447024
14 February 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467190
13 January 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388696
27 January 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386176

Deficiency record · 34

Construction/Loadline › Hull › Bottom Plating
Issued 23 September 2016 Resolved
Repair hull structure under generator via crop and renew IAW high strength steel welding procedures.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2016
Resolved 21 October 2016
Resolution: witnessed satisfactory repairs
Construction/Loadline › Structures › Deck Plating
Issued 23 September 2016 Resolved
Repair STBD hatch coming and provide satisfactory NDT
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2016
Resolved 21 October 2016
Resolution: witnessed satisfactory repairs
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 September 2016 Resolved
Provide alcohol testing capability.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 5 October 2016
Resolution: witnessed satisfactory alcohol test strips
Electrical › Electric Supply System (service) › Cable
Issued 23 September 2016 Resolved
Replace and secure wire connection in STBD engine room.
Due 30 September 2016
Resolved 5 October 2016
Resolution: witnessed satisfactory installation onboard.
Accommodation/Occupational Safety › Heating › Piping
Issued 23 September 2016 Resolved
Provide satisfactory lagging.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 21 October 2016
Resolution: witnessed satisfacoty lagging installation
Navigation › Piloting/Steering › Notices to Navigation
Issued 23 September 2016 Resolved
Provide chart correction kit.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 5 October 2016
Resolution: witnessed satisfactory chart correction kit and charts for AOR, as well as well as means to log updates. vessel did not have an area of operation because it is stacked therefore did not winess fully updated charts.
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 September 2016 Resolved
Repair hydraulic oil leak.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 5 October 2016
Resolution: witnessed satisfactory repair. vessel hydraulics operated without leaking hydraulic fluid
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 23 September 2016 Resolved
Provide permanent vessel crew. Note: vessel does not meet warm stack requirements per local policy.
Action required: 705 - Other - as specified
Due 23 October 2016
Resolved 5 October 2016
Resolution: cleared due to vessel meeting local warm stack policy requirments.
Operations/Management › Vessel Activity › Other
Issued 30 August 2016 Resolved
Properly man vessel in accordance with COI, conduct drills and complete required maintenance prior to sail. Vessel has been unmanned for approximately 1 year. The vessel is not incompliance with MSUMCINST 16711.1A "Warm stack and lay-up policy for OSV's and SPV's"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2016
Resolution: Cleared via satisfactory implementation of Warm stack program onboard and correct first set of required log entries.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 October 2015 Resolved
Provide proper operation of E-lighting prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2015
Resolved 23 October 2015
Resolution: 23OCT E-lighting working properly
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 October 2015 Resolved
Provide proper operation of Nav lights prior to night time operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2015
Resolved 23 October 2015
Resolution: Navigation lights operating properly
Engineering › Lubricating Oil Service System › Hose
Issued 1 October 2015 Resolved
Fix leaks on hydraulic hoses just fwd of fuel tanks.
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 October 2015
Resolution: New hydraulic hoses installed
Engineering › Fuel Oil Service System › Hose
Issued 1 October 2015 Resolved
Provide double hose clamps on stbd engine none metallic hose.
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 October 2015
Resolution: Double hose clamps installed on engine hose
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 October 2015 Resolved
Renew angle iron on port bottom in engine room.
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 October 2015
Resolution: New angle iron installed
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 1 October 2015 Resolved
Provide proper protection for port engine Exhaust Piping.
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 October 2015
Resolution: New exhaust lagging installed
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 1 October 2015 Resolved
Vessel operated without full compliment required by vessels COI.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2015
Accommodation/Occupational Safety › Potable Water System › General
Issued 20 July 2015 Resolved
Water heater Pressure/Temp Relief Valve has plug installed, bypassing a safety device. Secure power and tag out system until relief vale is replaced.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2015
Resolved 5 October 2016
Resolution: Talked with harold landry, issue had been cleared the previous year did not see any bypass device onboard in that system.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 20 July 2015 Resolved
MSD System piping not properly connected to tanks and system components not installed or serviceable. Use of any toilet is prohibited until the system is corrected IAW manufactures specifications.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2015
Resolved 5 October 2016
Resolution: bathroom/msd operated satisfactorily onbard.
Fire Fighting › Fire Pumps › Pressure
Issued 18 March 2010 Resolved
Fire pump did not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2010
Resolution: Upon return to vessel, fire pump was run and had 80 psi.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 18 March 2010 Resolved
Vessel's crane inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2010
Resolution: Crane was repaired and operated, small boat was put into the water as a test.
Operations/Management › Drills/Instruction › Fire
Issued 18 March 2010 Resolved
Drills not conducted due to vessel being off contract. Drills must be conducted and logged prior to sail by the crew actually manning the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2011
Resolution: Drills were logged, also conducted sat Fire, Abandon ship, & MOB drill.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 March 2009 Resolved
Provide an updated deviation table for vsl's mag compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2008 Resolved
Renew Port Navigation Light
Due 14 May 2008
Resolved 15 April 2008
Resolution: Renewed Port Navigation Light
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2008 Resolved
Stencil lights with markings
Due 14 May 2008
Resolved 15 April 2008
Resolution: Stenciled Water Lights.
Electrical › Electric Generation Source (service) › Generator
Issued 14 April 2008 Resolved
repair exposed wiring on generator.
Due 14 May 2008
Resolved 15 April 2008
Resolution: Repaired electrical wiring on generator.
Engineering › Lubricating Oil Service System › Hose
Issued 14 April 2008 Resolved
Install metallic supports for hydraulic lines in Engine room.
Due 14 May 2008
Resolved 15 April 2008
Resolution: Installed required metallic clamp supports.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 April 2008 Resolved
Replace Water Heater.
Due 14 May 2008
Resolved 15 April 2008
Resolution: Replaced water heater.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 April 2008 Resolved
Remove liquid from battery boxes.
Due 14 May 2008
Resolved 15 April 2008
Resolution: Removed liquid from battery boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2008 Resolved
Cap/Remove dead end wiring in vessel.
Due 14 May 2008
Resolved 15 April 2008
Resolution: Capper or Removed all dead end wiring in vessel.
Lifesaving › Lifejacket/PFD (General)
Issued 24 February 2003 Resolved
1) Renew reflective tape on 2 adult pfds. 2) Post pfd donning instructions in vicinity of life jacket locker.
Due 24 February 2003
Resolved 24 February 2003
Construction/Loadline › Hull
Issued 24 February 2003 Resolved
Insert angle @ strut in way of port rudder post.
Due 24 February 2003
Resolved 24 February 2003
Engineering
Issued 24 February 2003 Resolved
Repair exhaust lagging on both propulsion engines.
Due 24 February 2003
Resolved 24 February 2003
Stability › Weathertight Integrity
Issued 24 February 2003 Resolved
Renew gasket material on fwd escape hatches
Due 24 February 2003
Resolved 24 February 2003
Documentation
Issued 27 January 1998 Resolved
PROVIDE APPROVED STABILITY LETTER/OPERATIONS MANUAL PRIOR TO VESSEL OPERATING.
Condition: Unknown
Due 3 February 1998
Resolved 5 February 1998