Records from 1987 to 2024. Most recent: inspection, 29 April 2024.
Documentation record
Registered dimensions (L × B × D)63.3 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 148 / net 100
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · NEW ALBANY, IN, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOUISVILLE, KY
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it148 - Regulatory (Subpart C or D), Gross Ton
100 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
29 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7903404
21 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7770634
28 July 2022
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7509939
14 March 2022
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7411563
9 December 2021
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7363900
29 April 2019
Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6672362
10 April 2014
Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4836878
14 February 2012
DAPI Audit · Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4248925
8 June 2011
Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4039284
7 May 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4022058
15 April 2011
Industry Initiated Exam · MTSA Verification · Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3987063
10 June 2010
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3763617
13 May 2009
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3477717
15 January 2009
Administration
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3394704
21 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3243216
6 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3229597
13 April 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3197008
13 April 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3199101
23 November 2004
MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2247587
15 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2044719
11 December 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 183036
29 May 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 316462
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 August 2023
Resolved
A fixed fire pump must be capable of: (1) Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)); and (2) Being energized remotely from a safe place outside the engine room and at the pump. Vessels fixed fire pump has low pressure, PSI gauge was broken, fire pump main breaker was not labeled and fire main could not be energized and secured at each location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 18 September 2023
Resolution: Vessels fixed fire pump, PSI gauge was replaced, fire pump main breaker hs been labeled and fire main can be energized and secured at each location.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 August 2023
Resolved
Vessel fuel oil vent piping is restricted by rust and dirt. Clean or replace flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 5 September 2023
Resolution: CLEANED WITH WIRE BRUSH
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2023
Resolved
Pressure vessel relief valves must be tested or replaced twice in 5 years no more than 3 years. Vessel did not have proof of testing or purchase.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 18 September 2023
Resolution: Pressure vessel relief valves were replaced
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 August 2023
Resolved
Vessel needs to install a valid copy of their COD on the vessel bridge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 5 September 2023
Resolution: PLACED IN THE PILOT HOUSE
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 August 2023
Resolved
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Vessel was missing their certificates.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 5 September 2023
Resolution: RECEIVED FROM CINTAS AND PLACED ON VESSEL FILES
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 21 August 2023
Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. Vessel radio was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 25 August 2023
Resolution: REPLACED BATTERY BACKUP FOR PORT RADIO
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2023
Resolved
Vessels life rings line was dry-rot, replace life line and properly secure around the body of ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 18 September 2023
Resolution: replaced life line and properly secured around the body of ring.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 December 2021
Resolved
Capt. o/b did not have a Radio Operators permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 14 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 December 2021
Resolved
Vessel did not have required 3 day/3night flares OR 3 combination flares o/b.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 14 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 December 2021
No resolution recorded
Bridge windows had multiple cracks. Correct at next DryDock.
Action required: 705 - Other - as specified
Due 31 May 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021
Resolved
Steering air system below pilothouse appears to have a leak. Verify proper function of steering air lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 14 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021
No resolution recorded
Remote fuel shut off valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The current arrangement has the shut off next to the machinery. Owner shall make repairs at next dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2024 — due date passed with no resolution recorded