GAIL ANN

GAIL ANN is a 1981 towing vessel. The Coast Guard has recorded 22 inspections since 1987, most recently in April 2024, along with 12 deficiencies — 2 with no resolution recorded — and 3 casualty investigations between 2008 and 2011.

Records from 1987 to 2024. Most recent: inspection, 29 April 2024.

Built
1981
Last inspected
29 April 2024
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF8442
199650
Flag
UNITED STATES
Maury page id
psix-199650

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded7
…past their stated due date2
Years with a record 14 calendar years (1987–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)63.3 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 148 / net 100
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEW ALBANY, IN, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOUISVILLE, KY
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it148 - Regulatory (Subpart C or D), Gross Ton
100 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 7

Inspection history · 22

29 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7903404
21 August 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7770634
28 July 2022 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7509939
14 March 2022 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7411563
9 December 2021 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7363900
29 April 2019 Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6672362
10 April 2014 Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4836878
14 February 2012 Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4248925
8 June 2011 Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4039284
7 May 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4022058
15 April 2011 Industry Initiated Exam · MTSA Verification · Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3987063
10 June 2010 Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3763617
13 May 2009 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3477717
15 January 2009 Administration
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3394704
21 June 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3243216
6 June 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3229597
13 April 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3197008
13 April 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3199101
23 November 2004 MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2247587
15 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2044719
11 December 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 183036
29 May 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 316462

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 August 2023 Resolved
A fixed fire pump must be capable of: (1) Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)); and (2) Being energized remotely from a safe place outside the engine room and at the pump. Vessels fixed fire pump has low pressure, PSI gauge was broken, fire pump main breaker was not labeled and fire main could not be energized and secured at each location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 18 September 2023
Resolution: Vessels fixed fire pump, PSI gauge was replaced, fire pump main breaker hs been labeled and fire main can be energized and secured at each location.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 August 2023 Resolved
Vessel fuel oil vent piping is restricted by rust and dirt. Clean or replace flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 5 September 2023
Resolution: CLEANED WITH WIRE BRUSH
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2023 Resolved
Pressure vessel relief valves must be tested or replaced twice in 5 years no more than 3 years. Vessel did not have proof of testing or purchase.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 18 September 2023
Resolution: Pressure vessel relief valves were replaced
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 August 2023 Resolved
Vessel needs to install a valid copy of their COD on the vessel bridge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 5 September 2023
Resolution: PLACED IN THE PILOT HOUSE
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 August 2023 Resolved
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Vessel was missing their certificates.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 5 September 2023
Resolution: RECEIVED FROM CINTAS AND PLACED ON VESSEL FILES
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 21 August 2023 Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. Vessel radio was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 25 August 2023
Resolution: REPLACED BATTERY BACKUP FOR PORT RADIO
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2023 Resolved
Vessels life rings line was dry-rot, replace life line and properly secure around the body of ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 18 September 2023
Resolution: replaced life line and properly secured around the body of ring.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 December 2021 Resolved
Capt. o/b did not have a Radio Operators permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 14 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 December 2021 Resolved
Vessel did not have required 3 day/3night flares OR 3 combination flares o/b.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 14 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 December 2021 No resolution recorded
Bridge windows had multiple cracks. Correct at next DryDock.
Action required: 705 - Other - as specified
Due 31 May 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021 Resolved
Steering air system below pilothouse appears to have a leak. Verify proper function of steering air lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 14 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021 No resolution recorded
Remote fuel shut off valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The current arrangement has the shut off next to the machinery. Owner shall make repairs at next dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2024 — due date passed with no resolution recorded

Casualty record · 3

6 June 2008Routine · role: Transiting Vicinity of Primary Subject · activity 3229597
21 June 2008Routine · role: Sighted in Area · activity 3243216
7 May 2011Routine · role: Sighted in Area · activity 4022058
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.