Records from 1989 to 2012. Most recent: inspection, 27 July 2012.
Inspection history · 58
27 July 2012
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4392097
23 February 2012
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4249876
1 February 2010
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3673288
3 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3446527
17 March 2009
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3435490
11 February 2008
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3146278
16 April 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2909580
17 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2750898
20 July 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2719469
11 April 2006
Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2622323
8 February 2006
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2581493
9 February 2005
MTSA Verification · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2288120
3 March 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2016699
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998586
22 January 2003
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1730860
5 February 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1483969
31 August 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074041
6 March 2001
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1060158
2 February 2001
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468184
17 May 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 820501
4 February 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432259
1 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350121
12 April 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 787934
30 March 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785303
23 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776515
17 February 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453546
30 March 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786740
4 February 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406254
18 February 1997
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1106014
9 October 1996
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1392542
22 April 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 33774
22 April 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 83590
22 April 1996
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417943
24 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 70964
23 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 81627
26 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 679327
8 September 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416183
5 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212365
1 September 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398111
26 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391883
9 March 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1147190
10 August 1992
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471077
22 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439327
4 June 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946752
14 April 1992
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948640
4 December 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252157
29 August 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937641
30 July 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939207
30 July 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 960529
30 July 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1269992
26 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236649
10 February 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925202
17 October 1990
Inclining Experiment · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914234
27 April 1990
Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227914
23 February 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933330
22 February 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928042
6 October 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1021117
5 August 1989
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043996
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 23 February 2012
Resolved
Because the weak link was improperly installed and was missing the approval tag, operator must renew weak link with proper documentation.
Condition: Improper Installation
Due 1 March 2012
Resolved 5 March 2012
Resolution: Vessel owner ordered a new weak link and replaced w/l in the proper location.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 February 2010
Resolved
Prior to departure from port complete fire, security, and MOB drill to the satisfaction of attending marine inspector
Action required: 705 - Other - as specified
Resolved 12 February 2010
Fire Fighting › Nozzles › Condition
Issued 1 February 2010
Resolved
Stbd side fire hose all purpose nozzle leaks when shut. Provide proper maintenance for positive on/off operation.
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 12 February 2010
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 1 February 2010
Resolved
Label contact maker in fidley.
Action required: 705 - Other - as specified
Resolved 12 February 2010
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 1 February 2010
Resolved
Secure refrigerator for sea.
Action required: 705 - Other - as specified
Resolved 12 February 2010
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 1 February 2010
Resolved
Port main engine constantly stops during operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 March 2009
Resolved
Renew reflective tape and stencil "vessel name" on life rings.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 5 April 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 17 March 2009
Resolved
Replace non-metallic grab rail on generator switchboard.
Action required: 705 - Other - as specified
Due 17 March 2009
Resolved 17 March 2009
Navigation › Piloting/Steering › Marine Charts
Issued 11 February 2008
Resolved
Provide updated navigation charts.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 14 February 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 February 2008
Resolved
Provide 5 life jackets and destroy jackets found worn during inspection. Vessel is limited to 18 POB until jackets are replaced.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 14 February 2008
Stability › Watertight Integrity › General
Issued 11 February 2008
Resolved
Replace missing dog in hatch going to engine room stores prior to floating barge.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 14 February 2008
Communications › Radio Communications › EPIRB
Issued 17 April 2007
Resolved
Make repairs to EPIRB manual activation pull tab or renew epirb.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2007
Resolved 17 April 2007
Resolution: New EPIRB installed. Verified proper registration.
Lifesaving › Lifefloat › Serviceable
Issued 17 April 2007
Resolved
Send in life floats for inspection and repair prior to operation. Float external fiberglass coating and paint is breaking down.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2007
Resolution: New life floats installed.
Fire Fighting › Means of Escape › Blocked
Issued 17 April 2007
Resolved
Repair engineering storage room escape hatch lower handle
Condition: Improper/Lack of Maintenance
Due 17 April 2007
Resolved 17 April 2007
Resolution: Verified repairs made.
Stability › Watertight Integrity › General
Issued 17 April 2007
Resolved
Adjust main deck watertight hatches for proper seal.
Condition: Improper/Lack of Maintenance
Due 30 April 2007
Resolved 18 May 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 April 2007
Resolved
Modify starboard fuel oil remote fuel shut off to prevent binding during operation.
Condition: Improper Installation
Due 17 April 2007
Resolved 17 April 2007
Resolution: New reach rod fabricated, installed and tested satisfactory
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 July 2006
Resolved
Provide stability calc's that reflect the vessel as currently operated and outfitted, flooded pads/ vice dry, make corrections to operations manual and submitt for approval.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 17 August 2006
Resolution: Provided.
Engineering › Fuel Oil Service System › Pump
Issued 11 April 2006
Resolved
Repair fuel leak on port generator fuel pump
Condition: Improper/Lack of Maintenance
Due 24 April 2006
Resolved 11 April 2006
Resolution: Verified repair
Engineering › Sea-water System (primary cooling) › Pump
Issued 11 April 2006
Resolved
Renew deteriorated pump mounting bolts.
Condition: Improper/Lack of Maintenance
Due 11 April 2006
Resolved 11 April 2006
Engineering › Compressed Air System (start air) › Valve
Issued 11 April 2006
Resolved
Renew port air receiver pressure relief valve with proper PRV
Condition: Improper Installation
Due 11 April 2006
Resolved 11 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 February 2005
Resolved
No later thatn 02 Feb 06 (next dry dock) make port generator and port Main Diesel Engine Exhaust piping accessible for inspection by U.S. Coast Guard for the purpose of locating and repairing exhaust leaks.
Due 6 February 2006
Resolved 14 April 2006
Communications › Radio Communications › Emergency Source of Power
Issued 3 March 2004
Resolved
Install new battery for emergency power on bridge and prove proper operation of radio and GQ alarm on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2004
Resolution: New battery installed and radios and GQ tested sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 3 March 2004
Resolved
Prove proper operation of automation alarm panel on bridge.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2004
Resolution: Repairs made to panel and alarms tested sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 March 2004
Resolved
Prove proper operation of high level bilge alarm in starboard engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2004
Resolution: Alarm repaired and tested sat.
Construction/Loadline
Issued 2 February 2001
Resolved
Crop and renew potable water tank bulkhead in way of Number 4 port ballast tank.
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Repair tripped diagonal stiffener in way of Number 4 port ballast tank.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
make permanent repairs to frames 7, 10, 14, 15 in port bow rake.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Make repairs to deep web frame #2 in port preload tank.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Crop and renew tripped floor angles and trip plates in way of foward port sponson.
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Complete weld on insert in way of aft bulkhead in port aft sponson.
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Fire Fighting
Issued 2 February 2001
Resolved
Provide and prove proper operation of port side secondary fire pump.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Navigation
Issued 2 February 2001
Resolved
Replace or make repairs to single sideband radio.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Engineering
Issued 2 February 2001
Resolved
Install and prove proper operation of main engine remote stops.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Engineering
Issued 2 February 2001
Resolved
Make permanent repairs to vent piping in storage area.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Crop and renew transverse deck angle in port engineroom.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Renew all tank vent screens and ensure proper operation of closing devices.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Lifesaving
Issued 2 February 2001
Resolved
Renew man rope for emergency escape on starboard aft side.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Make repairs to fractures in framing members and plating in deck insert above stbd main diesel engine.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
repair reachrod and free up preload dump valve in stbd preload tank.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
make repairs to headlog framing and replace timbers as needed.
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Construction/Loadline
Issued 2 February 2001
Resolved
Crop and renew foward transverse bulkhead from overhead to new insert in way of port sponson.
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Construction/Loadline
Issued 4 February 2000
Resolved
PROVIDE "A" CLASS WTD FOR GALLEY TO ENGINE ROOM BULKHEAD CLOSURE, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 February 2000
Resolved 4 February 2000
Accommodation/Occupational Safety
Issued 4 February 2000
Resolved
PROVIDE MEANS OF EGRESS FROM 01 LEVEL EMERGENCY ESCAPES TO MAINDECK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 February 2000
Resolved 4 February 2000
Fire Fighting
Issued 30 March 1999
Resolved
Demonstrate proper operation of fire pump in accordance with 46CFR95.05-10 to the satisfaction of the attending marine inspector. Neither eng room fire pump or submersible pump produce 50 psi. Vsl allowed to operate using pumps in tandem to produce required pressure.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Documentation
Issued 17 February 1999
Resolved
PROVIDE EMPLOYEE ASSITANCE PROGRAM PER 46 CFR 16.
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Construction/Loadline
Issued 17 February 1999
Resolved
PROVIDE VENT CLOSURE DEVICES FOR BOTH PRE LOAD TANK VENTS PER 46 CFR 56.50-85(a)(7)._x001C_ .
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Lifesaving
Issued 17 February 1999
Resolved
DEMONSTRATE COMPLIANCE WITH COAST GUARD DISTRICT EIGHT POLICY LETTER DATED 12NOV98, "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS."_x001C_
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Documentation
Issued 17 February 1999
Resolved
PROVIDE NEW STABILITY LETTER REFLECTING REVISION 2 TO OPERATIONS MANUAL.
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Electrical
Issued 17 February 1999
Resolved
PROVIDE EMERGENCY LIGHTING FOR ENGINE ROOM EMERGENCY ESCAPES PER 46 CFR 112.
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Fire Fighting
Issued 4 February 1998
Resolved
PROVIDE UPDATED AND LEGIBLE FIRE/SAFETY PLAN FOR USCG APPROVAL AND TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Documentation
Issued 5 August 1989
Resolved
PROVIDE APPROVED STABILITY AND OPERATIONAL MANUAL.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989
Documentation
Issued 5 August 1989
Resolved
SUBMIT THE FOLLOWING PLANS FOR APPROVAL TO [name withheld]: (1) OUTBOARD AND INBOARD PROFILE PLANS, (2) SAFETY, FIRE CONTROL, (3) ALL HYDRAULIC SYSTEMS, (4) CALCULATION FOR LEGS.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989
Unknown
Issued 5 August 1989
Resolved
SUBMIT PLANS FOR APPROVAL AND INSTALL TILT ALARMS.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989
Documentation
Issued 5 August 1989
Resolved
PROVIDE PROPER DOCUMENTATION.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989
Navigation
Issued 5 August 1989
Resolved
INSTALL RUDDER ANGLE INDICATOR IN WHEELHOUSE.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989
Unknown
Issued 5 August 1989
Resolved
PROVIDED COAST GUARD APPROVED RESCUE BOAT.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989
Unknown
Issued 5 August 1989
Resolved
PROVIDE COAST GUARD APPROVED MSD SYSTEM.
Condition: Unknown
Due 5 August 1989
Resolved 5 August 1989