Records from 2001 to 2025. Most recent: inspection, 27 March 2025.
Documentation record
Registered dimensions (L × B × D)56.5 ft × 22.1 ft × 8.4 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY'S BOAT BUILDERS · MORGAN CITY, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCROWN POINT, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 August 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
27 March 2025
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8100744
21 March 2025
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8097487
20 December 2023
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7836020
20 December 2019
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6877223
17 April 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6664872
9 May 2016
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5868073
18 September 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4718083
18 September 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4718711
3 December 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4505686
9 August 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4413739
24 July 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4411624
28 January 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4234626
30 April 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4007302
21 July 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3801852
30 April 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3727623
23 January 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3398888
16 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364304
8 May 2006
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2643953
9 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2003281
15 September 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212825
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2025
Resolved
A towing vessel that is: Certificated for rivers, lakes, bays, and sounds, less than 3 nautical miles from shore on the Great Lakes; must be equipped with an approved 160-B semi-portable fire-extinguishing system to protect the engine room. Semi-portable was on second deck unable to reach all areas of engine room. Ensure semi-portable is moved to reach all spaces of engine room to marine inspector satisfaction.
46 CFR 142.315(a)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2026
Resolved 10 February 2026
Resolution: moved to main deck
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 27 March 2025
Resolved
The owner, managing operator, or master of each towing vessel must maintain the required navigational-safety equipment in a fully-functioning, operational condition. Towing vessels must be equipped with a fathometer. Newly installed fathometer was found not functioning properly. Verify satisfactory operation to the satisfaction of Marine Inspector.
46 CFR 140.620.(b)
46 CFR 140.725 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 10 February 2026
Resolution: fully operational
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 27 March 2025
Resolved
The type and quantity of chemicals that are required to operate the device, including instructions on the proper handling, storage and use of these chemicals. Vessel was missing the bio-activator chemical for device. Get both bio-activator and bio-enhancer on board to satisfaction of Marine Inspector.
33 CFR 159.57(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 10 February 2026
Resolution: added all chemicals
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 March 2025
Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. Radios did not remain powered during loss of power test. Verify satisfactory operation to the satisfaction of Marine Inspector.
46 CFR 140.715 (b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 10 February 2026
Resolution: Radio is fully operational on battery back up.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025
No resolution recorded
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. As of 20Mar25, the vessel is overdue for its annual exam. Vessel is prohibited from commercial operations until it complies with the required examinations.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine inspectors found port rudder post bearings worn allowing for excessive vibration and unusual movement during steering checks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2024
Resolution: While underway, conducted operational steering test. Witnessed proper operation of propulsion machinery and all steering system components. All cutlass bearings, props, and shafts were replaced. No deficiencies noted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 December 2023
Resolved
Each towing vessel must be operated in compliance with: (a) The Maritime Transportation Security Act of 2002 (46 U.S.C. Chapter 701); and (b) 33 CFR parts 101 and 104. Found expired security plan. Vessel is restricted from pushing red flag barges until security plan approval letter is provided.
Action required: 705 - Other - as specified
Resolved 24 January 2024
Resolution: Inspected vessel security plan and verified valid and current security plan approval letter onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 December 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
No.1 and No.2 voltage indicators and power available lights were found to be inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found that the voltage and power available indicators and lights on main electrical switchboard were replaced and operational.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 December 2023
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Found port generator prime mover exhaust pipe missing sufficient lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found lagging on port prime mover exhaust piping was properly installed
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 December 2023
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Found melted lighting fixture in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found melted light fixture in the engine room was satisfactorily replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 20 December 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Found water heater base rusted and leaking excessive water in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found the engine room water heater was replaced in kind with new unit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 December 2023
Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Found lifebouy grab line wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Life buoy grab lines were replaced and inspected with no deficiencies noted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 December 2023
Resolved
An internal structural examination required by this part may be conducted while the vessel is afloat or while it is out of the water. It consists of a complete examination of the vessel's main strength members. Observed excessive wastage on transverse and longitudinal structural members below port and starboard shafts. Provide gauging report/repair plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Inspected structural conditions; Found transverse and longitudinal structural members below port and starboard shafts areas were properly cropped and renewed to remove wastage.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 December 2023
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil in bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found the engine room bilge areas cleaned and without excessive oil.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 20 December 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Observed battery replacement alert on engine room alarm monitoring system panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found engine room alarm monitoring panel battery was replaced and properly operating. Crew provided receipts as proof of recent install date.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 December 2023
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Observed no guard to protect crew from moving parts of slop pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: Found proper machinery guard was installed on slop pump.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 September 2013
Resolved
Machinery inside engine room did not have machinery guards on crankshaft pulley creating a hazardous condition.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2013
Resolution: Vessel found to have proper machinery guards on rotating crankshaft pulley.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 September 2013
Resolved
Vessel did not a valid COD onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2013
Resolution: Vessel was found to have valid COD onboard.