← All vessels
MANTA RAY
Offshore Supply Vessel · Offshore class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named MANTA RAY
MANTA RAY is a 1981 offshore supply vessel. The Coast Guard has recorded 48 inspections since 1989, most recently in June 2016, along with 18 deficiencies and 1 casualty investigation in 2011.
Records from 1989 to 2016. Most recent: inspection, 27 June 2016.
- Built
- 1981
- Last inspected
- 27 June 2016
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
639744
8765876 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH5374
200837
Flag
UNITED STATES
366947790, 367032460, 367627340 (licence lapsed)
Maury page id
psix-200837
Inspections, by type
…with no type recorded11
Years with a record
23 calendar years (1989–2016)
The 48 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)87.5 ft × 48.0 ft × 7.8 ft
Registered tonnagegross 194 / net 163
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it194 - Regulatory (Subpart C or D), Gross Ton
163 - Regulatory (Subpart C or D), Net Ton
163 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH5374MMSI 367627340 · expired · compulsorily equipped · granted 13 June 2014, cancelled 17 August 2024
WDC4895MMSI 367032460 · expired · compulsorily equipped · granted 9 April 2005, cancelled 13 June 2015
WDB7772MMSI 366947790 · expired · compulsorily equipped · granted 14 May 2004, cancelled 19 July 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 48
27 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5921304
15 May 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4312197
8 December 2011
Examination of Repairs · COI Inspection · MTSA/ISPS Verification · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4204273
7 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4073169
8 February 2011
Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3941738
8 February 2011
Administrative Inspection · Examination of Repairs · Ballast Water Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3951047
29 December 2009
Ballast Water Examination · Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3656424
3 December 2008
Ballast Water Examination · Annual Inspection · Hull Examination · Examination of Repairs · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3373687
13 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3056995
10 October 2006
Deficiency Check · MTSA Verification · Ballast Water Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2797069
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539898
1 November 2005
MTSA Verification · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2527053
14 February 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2292025
16 December 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260358
23 August 2004
Examination of Repairs · Re-Inspection · Hull Examination · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2173779
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972257
16 December 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1965194
13 August 2002
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664259
26 July 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467782
9 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119672
1 July 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406522
25 September 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375500
10 July 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419808
20 December 1996
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447664
6 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 78266
8 August 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355897
30 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 480789
19 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412837
16 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866596
18 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 694620
23 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 175860
8 June 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367075
4 October 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 846860
13 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385110
13 May 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 835650
11 September 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 153553
8 July 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370489
26 June 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414078
11 June 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265571
2 March 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 15380
2 March 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 668811
10 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 668810
26 June 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933699
23 July 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234446
25 October 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915588
28 September 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1307238
5 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886530
9 June 1989
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195715
Deficiency record · 18
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 December 2011
Resolved
Place emergency lighting in O3 deck as indicated
Electrical › Electrical Distribution System (service) › Switch
Issued 8 December 2011
Resolved
Generator emergency kill switch located on the bridge inoperable
Engineering › Bilge Water Management System › Valve
Issued 8 December 2011
Resolved
Label all bilge/ballst valves as indicated
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 December 2011
Resolved
Clean port generator exhaust lagging
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 22 February 2011
Resolved
Replace Stbd engine room air receiver.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 23 August 2004
Resolved
Provide local propulsion control per NVIC 1-78 in engine room.
Construction/Loadline › Hull › Hull Plating
Issued 23 August 2004
Resolved
Port engine room over head deck plate in way of blower housing wasted. Repair at next annual inspection.
Lifesaving
Issued 1 July 1999
Resolved
DEMONSTRATE COMPLIANCE WITH D8 POLICY LETTER DATED 12NOV98 "RESCUE BOAT REQUIREMENTS FOR OFFSHORE SUPPLY VESSELS" TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Unknown
Issued 9 June 1989
Resolved
INSTALL NEW SEA VALVE FOR BILGE PUMP PRIMING/BALLAST PRE LOAD INTAKE.
Unknown
Issued 9 June 1989
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL (AND LOG) WITHIN TWENTY-FOUR (24) HOURSAFTER GETTING UNDER WAY IN ACCORDANCE WITH 46 CFR 97.15-35.
Unknown
Issued 9 June 1989
Resolved
POST COPIES OF LIFESAVING SIGNALS IN THE APPROPRIATE LOCATIONS.
Unknown
Issued 9 June 1989
Resolved
PROVIDE "DEAD-MAN" TYPE NOZZLES FOR DECK REFUELING STATION.
Unknown
Issued 9 June 1989
Resolved
PROVIDE COPIES OF LIGHT LIST AND TIDE TABLES ONBOARD VESSEL.
Unknown
Issued 9 June 1989
Resolved
REPAIR AIR LINE TO PORT MAIN ENGINE REDUCTION GEAR CONTROL.
Unknown
Issued 9 June 1989
Resolved
MARK ALL VALVES IN ENGINE ROOM FOR SYSTEM SERVED.
Unknown
Issued 9 June 1989
Resolved
PROVIDE ADEQUATE FIRE MAIN PRESSURE, ADD PRESSURE VALVES ON DISCHAGE SIDE OF BOTH FIRE PUMPS (FIRE MAIN PRESSURE CURRENTLY 30LBS/IN2).
Unknown
Issued 9 June 1989
Resolved
PROVIDE FOR INSPECTION INTERNAL EXAMINATION OF BOTH ARE RECEIVERS AND TEST OF RELIEF VALVES.
Documentation
Issued 9 June 1989
Resolved
SUBMIT FOR APPROVAL TO COGNIZANT [name withheld] PLAN. COMPLIANCE DATE IS: 09JUL89
Casualty record · 1
15 April 2011Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4013298
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.