MAURY USCG vessel records Sign in
← All vessels

FISH SCREAMER III

FISH SCREAMER III is a 1981 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2004, most recently in March 2026, along with 44 deficiencies.

Records from 2004 to 2026. Most recent: inspection, 11 March 2026.

Built
1981
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI8043
201353
Flag
UNITED STATES
367047880 (licence lapsed)
Maury page id
psix-201353

Inspections, by type

…with no type recorded7
Years with a record 18 calendar years (2004–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)35.9 ft × 14.2 ft × 4.5 ft
Registered tonnagegross 15 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builder#1 BOAT MFG INC-HULL · KEY WEST, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLITTLE RIVER, SC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

EX340MMSI 367047880 · expired · exemption · granted 2 December 2025, cancelled 27 June 2026
WDI8043MMSI 367047880 · expired · compulsorily equipped · granted 17 May 2016, cancelled 27 June 2026
WDC5882MMSI 367047880 · expired · compulsorily equipped · granted 7 June 2005, cancelled 8 August 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

11 March 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8325052
14 January 2026 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8296430
12 March 2025 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8080563
12 March 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7878188
10 January 2024 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7848093
8 June 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7710348
3 March 2022 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7394903
13 January 2022 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7379734
22 April 2021 In-Service Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7176044
19 February 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7143090
20 April 2020 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6936564
9 March 2020 Hull Examination · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6922854
5 June 2019 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6704882
8 May 2019 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6679349
16 April 2019 Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6663313
23 April 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6397173
28 February 2018 Drydock Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6363020
27 February 2018 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 6364639
24 April 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6131249
10 May 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5873349
10 March 2016 Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5830309
23 February 2016 Type not recorded
No type recorded · USCGC ELM (WLB 204) · USCG East District (CGD-E) · Activity 5820620
22 January 2016 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 5804984
3 January 2016 Type not recorded
No type recorded · USCGC DEPENDABLE (WMEC 626) · Activity 5796394
19 March 2014 Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4819486
19 December 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4211009
13 September 2011 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4143998
21 April 2009 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3457616
15 October 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3362276
5 September 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3049904
12 April 2007 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2907115
20 January 2005 Type not recorded
No type recorded · Violation Case Coordination Center · Activity 2277907
14 December 2004 Type not recorded
No type recorded · USCGC BLOCK ISLAND (WPB 1344) · USCG East District (CGD-E) · Activity 2265147
19 November 2004 Initial Certification · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2244286

Deficiency record · 44

05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 April 2020 Resolved
VHF radio must have MMSI programed and be connected to GPS. Current radio does not comply.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 April 2020 Resolved
Survival craft paddles must be marked with vessel name. The name is faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 April 2020 Resolved
Drug and alcohol program does not meet the requirements; pre-employment testing, crew contract and training, etc. Create a binder and provide proof to USCG that requirments are met.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2020 Resolved
Fuel hose must be serviceable. The STBD fuel supply hose is showing signs of dry-rot. Replace with CG approved SAE J 1942 hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2020 Resolved
Electrical installations shall be installed to provide safety to crew. The bandit rig junction box inside the engine compartment is broke and not a safe install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 May 2019 Resolved
The master does not have an FCC Radio Opertor Permit,provide proof of valid operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2019
Resolved 20 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 May 2019 Resolved
The vessel is not equipped with a current Navigation Rules; provide the vessel with a current publication.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2019 Resolved
One life jacket light is not operational, repair or replace as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 May 2019 Resolved
The first aid kit inventory is not complete, provide equipment as necessary to insure proper inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 23 April 2018 Resolved
Provide 2 additional adult lifejackets (Type I) with light, retro, and name of vsl.
Action required: 705 - Other - as specified
Resolved 1 May 2018
Resolution: Two new Type I life jackets have been placed onboard.
Communications › Radio Communications › EPIRB
Issued 23 April 2018 Resolved
Provide most recent EPIRB registration for EPIRB ADCD0 221A1 43001
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2018
Resolution: The existing EPIRB was re-registered.
Lifesaving › Lifebuoys › Serviceable
Issued 24 April 2017 Resolved
Replace the ring buoy due to missing grab lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 24 April 2017 Resolved
Provide the vessel with a BII fire extinguisher, existing extinguisher is the improper size.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2017 Resolved
Provide a metal splint for the first aid kit.
Due 8 May 2017
Resolved 25 April 2017
Communications › Radio Communications › EPIRB
Issued 16 May 2016 Resolved
Provide proof of properly installed CAT 1 EPIRB registered to vsl.
Due 18 May 2016
Resolved 18 May 2016
Resolution: Received emailed photos of installed CAT 1 EPIRB and documentation for registration request with NOAA.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 16 May 2016 Resolved
Provide 2015 MIS report.
Due 16 June 2016
Resolved 2 June 2016
Resolution: Proof of 2015 MIS report was forwareded electronically and reviewed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 May 2016 Resolved
Provide alcohol test strips, in date, minimum of 2.
Due 16 June 2016
Resolved 2 June 2016
Resolution: Recieved email picture of 3 in date alcohol test strips to be placed onboard vessel.
Documentation › Certificates/Documents › FCC SSL
Issued 16 May 2016 Resolved
Provide current FCC station license.
Due 16 June 2016
Resolved 2 June 2016
Resolution: Received email receipt from FCC requestion new station license.
Lifesaving › Hand Flares › Storage
Issued 13 September 2011 Resolved
Procure waterproof box for distress signals and label box.
Action required: 705 - Other - as specified
Due 13 October 2011
Resolved 14 September 2011
Lifesaving › Lifefloat › Paddle
Issued 13 September 2011 Resolved
Label paddles and paint orange
Action required: 705 - Other - as specified
Resolved 14 September 2011
Fire Fighting › Fire Bucket › Availability
Issued 13 September 2011 Resolved
Procure fire buckets.
Action required: 705 - Other - as specified
Resolved 14 September 2011
Navigation › Piloting/Steering › Marine Charts
Issued 13 September 2011 Resolved
Procure navigational charts
Action required: 705 - Other - as specified
Resolved 19 December 2011
Resolution: ADMINISTRATIVELY CLOSED DUE TO VESSEL INACTIVITY
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 September 2011 Resolved
Post lifejacket donning placard
Action required: 705 - Other - as specified
Resolved 14 September 2011
Fire Fighting › Ventilation Systems › Operating Controls
Issued 13 September 2011 Resolved
Label ventilation shutdowns
Action required: 705 - Other - as specified
Resolved 14 September 2011
Construction/Loadline › Penetrations › Gasket
Issued 21 April 2009 Resolved
Seal wire piping from engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 June 2009
Construction/Loadline › Hull › Hull Plating
Issued 21 April 2009 Resolved
Make repairs to 03 marked areas on starboard side hull.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 June 2009
Engineering › Fuel Oil Service System › Valve, Control
Issued 21 April 2009 Resolved
Prove proper operation and mark emergency fuel shutoffs.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 June 2009
Construction/Loadline › Structures › Manhole
Issued 21 April 2009 Resolved
Prove weather tight integrity of forward escape hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 June 2009
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 21 April 2009 Resolved
Provide serviceable propeller.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 29 June 2009
Communications › Alarms/Indicators › High Water Alarm
Issued 21 April 2009 Resolved
Label high water alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 June 2009
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 April 2009 Resolved
Seperate childrens PFDs from adult PFDs.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 June 2009
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 October 2008 Resolved
Replace hydrostatic release for epirb
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 October 2008 Resolved
Provide proof of registration renewal for epirb
Condition: Unknown
Due 1 November 2008
Resolved 19 November 2008
Construction/Loadline › Structures › Scuttle
Issued 15 October 2008 Resolved
Replace hatch seal for aft hatch.
Condition: Unknown
Due 1 November 2008
Resolved 19 November 2008
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 15 October 2008 Resolved
Provide fire barrier material for over head of engine hatch and forward engine room bulkhead.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 November 2008
Resolved 29 June 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 15 October 2008 Resolved
Provide a suitable means for securing engine room vents.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2008
Resolved 29 June 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 October 2008 Resolved
Provide valid COD
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2008
Lifesaving › Rescue Boat Equipment › Whistle/Sound Signal
Issued 5 September 2007 Resolved
Provide (4) whistles for PFD's
Condition: Unknown
Due 17 September 2007
Resolved 7 September 2007
Resolution: 04 whistles provided.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 5 September 2007 Resolved
Service portable and fixed fire fighting equipment.
Condition: Unknown
Due 17 September 2007
Resolved 7 September 2007
Resolution: Fixed fire system serviced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 September 2007 Resolved
Provide non corrosive clip for ring buoy strobe light.
Condition: Improper Installation
Due 17 September 2007
Resolved 7 September 2007
Resolution: Non-corrosive clip provided.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 5 September 2007 Resolved
Provide 30X30 mesh flame screen for port and stbd fuel vents.
Condition: Improper Installation
Due 17 September 2007
Resolved 7 September 2007
Resolution: New fuel vent fittings provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 September 2007 Resolved
Prove proper operation of nav lights.
Condition: Improper/Lack of Maintenance
Due 17 September 2007
Resolved 7 September 2007
Resolution: New nav light arrangements installed.
Engineering › Bilge Water Management System › Not Operational
Issued 5 September 2007 Resolved
Prove proper operation of all bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2007
Resolution: fixed pumps.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 September 2007 Resolved
Provide suitable arrangement for stern light when canopy is in place.
Condition: Improper Installation
Due 17 September 2007
Resolved 7 September 2007
Resolution: Stern light was mount up on a bracket for increased visibility

Ownership record