MAURY USCG vessel records
← All vessels

LESLIE ANN

LESLIE ANN is a 1981 towing vessel. The Coast Guard has recorded 10 inspections since 2010, most recently in January 2026, along with 39 deficiencies.

Records from 2010 to 2026. Most recent: inspection, 15 January 2026.

Built
1981
Last inspected
15 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDL6608
201569
Flag
UNITED STATES
Maury page id
psix-201569

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2010–2026)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)34.4 ft × 15.4 ft × 5.5 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEE TOWING CO., INC. · ORANGE, TX, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPASCAGOULA, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SILVER DIAMOND Towing Vessel · MISLE 290142 · 23 March 2010 · activity 3701176QUARTERHORSE Towing Vessel · MISLE 662491 · 23 March 2010 · activity 3701176

Inspection history · 10

15 January 2026 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8295999
30 October 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8254086
15 January 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8063987
5 January 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7845637
31 January 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7630012
6 April 2022 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7425608
2 November 2020 Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7088024
24 August 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7041544
22 August 2011 Deficiency Check · MARPOL · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4127054
23 March 2010 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 3701176

Deficiency record · 39

10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 January 2025 Resolved
Vessels navigational charts and publications were not up to date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 2 April 2025
Resolution: Vessel rep. purchased new publications.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2024 Resolved
A vessel must be equipped with: (i) An approved 160–B semi-portable fire-extinguishing system to protect the engine room. Vessels 160B FE pressure gauge was indicating empty.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 1 February 2024
Resolution: Vessel had fire extinguisher serviced and pressure guage was reading adequate pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Vessel had one pump not operating properly and the other failed to energize.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 1 February 2024
Resolution: Tested both bilge pumps and both were found to be satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 January 2024 Resolved
Each life float and rigid buoyant apparatus must be fitted with a lifeline, pendants, a painter, and floating electric water light approved under approval series 161.010. Vessels waterlight battery was found to be expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2024 Resolved
Each lifejacket must be marked: (1) In block capital letters with the name of the vessel. Vessel had multiple LJ's without the vsl name stenciled on.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator labeled LJ's.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 January 2024 Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel’s lifesaving and fire suppression and detection equipment and is in good working order. Vessels fire nozzle had no gasket and was leaking excessively from the connection point.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator replaced hose and nozzle.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 January 2024 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessels charts and pubs were not up to date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator acquired updated charts and pubs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Vsl's smoke detector in the galley failed to operate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator replaced smoke detector.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 31 January 2024 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Breaker panel in the eng. rm. had a cover that was not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator replaced breaker panel.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 31 January 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Identified a dead end wire above the port MDE and a grounding strap on the stbd side switchboard that was not properly grounded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Operator removed dead end wire and secured grounding strap.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 31 January 2024 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 20 February 2024
Resolution: Vessel clad welded hole in the top of potable water tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 January 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The fuel hose on the generator after the filter was found to be dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 21 April 2024
Resolution: Vsl rep. sent in photo of new hose for the generator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2023 Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station. Vessel only had 3 lifejackets onboard. A total of 6 lifejackets shall be onboard, one placed on the bridge and another in the engine room.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2023
Resolution: Replaced necessary lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 January 2023 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Vessel is required to have 6 red hand held flares and 6 orange flares for a total of 12 flares.Vessel only had a total of 6 distress signals.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2023
Resolution: Replaced necessary flares
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 January 2023 Resolved
Survival craft and stowage locations must be marked in accordance with the requirements of §§ 199.176 and 199.178 of this chapter. Retro-reflective tape on life float needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 February 2023
Resolution: Replaced retro
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. STBD side bilge piping found wasted. Repair/replace piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2022
Resolution: Documentary evidence provided showing proper repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Jacket water piping on Port main engine and generator found wasted. Repair/replace piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2022
Resolution: Documentary evidence provided showing proper repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Fuel filter flame screens were not installed. Install flame screen on all fuel filters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2022
Resolution: Documentary evidence rcvd showing flame screens installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2022 Resolved
Distress signals must be stowed in a properly marked portable watertight container at the operating station. Distress signals were not stowed in a container. Properly stow distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 15 April 2022
Resolution: Documentary evidence rcvd. Flares stowed in properly labeled container.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 November 2020 Resolved
Each life float and ridgid buoyant apparatus must be fitted with a lifeline, pendants, painter, and floating electric waterlight. Vessel survival craft did not have a painter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 November 2020 Resolved
Vessel survival craft had holes, and is in need of repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 November 2020 Resolved
Marine employer must have sufficient number of alcohol testing devices onboard. Vessel did not have testing devices onboard to be completed within minimum time frame.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 November 2020 Resolved
Fuel shut off valves were not labled, nor had direction of proper use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 November 2020 Resolved
06-11-11116-Vessel will be operating greater than three nautical miles from shore and will be required to have 6 day and 6 night distress signals-46CFR141.375(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2020 Resolved
07-10-10113 - Vessel did not have maritime mobile service identifier numbe programed into required radio equipment. 33CFR164.469(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 2 November 2020 Resolved
08-09-091-09109 Vessel piping and systems not color coded and labeled to identify functions. 46 CFR 143.250(e)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2020 Resolved
09-11-11117- Vessel life buoy water lights not of an approved series. 46 CFR 141.360(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 November 2020 Resolved
10-13-13104 - Starboard bilge piping was severly wasted and in need of replacement. 46 CFR 143.245(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 2 November 2020 Resolved
11-10-10119 - Vessel does not have a means to monitor rudder angle at the operating station. 46 CFR 143.225(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 January 2021
Resolution: Vessel granted special consideration until next scheduled DD see COI note and special note
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 November 2020 Resolved
12-09-092-09233 - Vessel main engines have exposed rotating machinery. 46 CFR 143.205(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2020 Resolved
13-09-092-09209 Vessel had exposed opening in breaker panel. 46 CFR 143.400(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 November 2020 Resolved
14-04-04114 - Vessel generator does not have required gauges per regulations. 46 CFR 143.230(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 November 2020 Resolved
15-08-08199 - Vessel does not have required alarms for generator. 46 CFR 143.230(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2020 Resolved
16-07-07110- Vessel did not have procedure for monthly inspections to be carried out on portable and semi-portable fire extinguishers. 46 CFR 142.240(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2020 Resolved
17-13-13199 - Vessel did not have documented fuel mainenance plan. 46 CFR 143.255(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2020 Resolved
18-07-07110 - Portable fire extiguisher brackets are not of approved type, missing bottom support. 46 CFR 142.125(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 November 2020 Resolved
19-11-N/A-11132 - Vessel did not have documented plan to test and exam essential systems. 46 CFR 245(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 17 November 2020
Resolution: Captain submitted objective evidence to clear def's, additionally MI's conducted virtual inspection to review and clear some of the def's issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2020 Resolved
20-13-NA-13199- Relief valve on pressure vessel capacity is unknown, last testing is also unknown. Pressure vessel was not secured to deck or bulkhead. 46 CFR 143.300(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 17 November 2020
Resolution: Removed pressure vessel
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2020 Resolved
An existing towing vessel subject to this subchapter will remain subject to Coast Guard regulations applicable to the vessel on July 19, 2016 until either July 20, 2018 or the date the vessel obtains a COI, whichever date is earlier. Due to the company not meeting the requirements of 46 CFR 136.202(a)(2), Marine Inspectors attended vessel to ensure compliance with Subchapter M. Upon attendance attending MI's discovered objective evidence that the vessel is not in compliance with Subchapter M. Vessel is required to meet one of the following: either have the vessel surveyed in accordance with 46 CFR parts 137.215 and 137.220 by a qualified surveyor as stated in 46 CFR 139.130 OR an inspection completed by the CG. The vessel will be required to have a COI prior to operating. Objective Evidence to include but not limited to; - No record of items to be recorded - Excessive oily water in bilge - Could not verify high level bilge alarm - General Electrical Safety 46 CFR 136.172
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.