← All vessels
JOANNE I
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named JOANNE I
JOANNE I is a 1975 freight ship. The Coast Guard has recorded 22 inspections since 2001, most recently in May 2004, along with 20 deficiencies and 8 operational controls.
Records from 2001 to 2004. Most recent: inspection, 1 May 2004.
- Built
- 1975
- Last inspected
- 1 May 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7358690 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP8028
20171
Flag
PANAMA
—
Maury page id
psix-20171
Inspections, by type
…with no type recorded15
Years with a record
4 calendar years (2001–2004)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1507 - Regulatory (Subpart C or D), Gross Ton
1507 - Convention (Subpart B), Gross Ton
874 - Regulatory (Subpart C or D), Net Ton
874 - Convention (Subpart B), Net Ton
2550 - Dead Weight, Ton
1507 - Convention (Subpart B), Gross Ton
874 - Regulatory (Subpart C or D), Net Ton
874 - Convention (Subpart B), Net Ton
2550 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
1 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2057184
29 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2055371
13 April 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2043714
8 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040343
17 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2026158
16 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2025549
15 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2024562
23 January 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1991254
20 January 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1988801
10 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1901740
7 August 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1872116
17 July 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1848724
24 March 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1762149
13 January 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1729394
2 July 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1639955
11 June 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1629044
15 April 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1604732
23 July 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 292175
25 June 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 291221
13 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 289056
3 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287396
2 February 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286739
Deficiency record · 20
Lifesaving › Lifeboat Equipment › Food Ration
Issued 23 January 2004
Resolved
Replace all not properly sealed rations in lifeboat. Submit by fax copy of purchase of rations to MSO Miami Office. 60 SOLAS III/11(a)(xii)
Documentation › Certificates/Documents
Issued 17 July 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Logs/Records
Issued 13 January 2003
Resolved
Commence providing mandatory reporting of ballast IAW 33 CFR 151.2040 (c). Pior to US port call after operating beyond the EEZ. LEGACY COMPONENT DESC: Ballast Water Reporting Form
Navigation › Piloting/Steering
Issued 15 April 2002
Resolved
Provide warning statement for maneuvering fact sheet IAW 33 CFR 164.35. LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Operations/Management › Navigation Safety
Issued 15 April 2002
Resolved
Provide sailing directions IAW 33 CFR 164.33.
Fire Fighting › Fire Main
Issued 15 April 2002
Resolved
Make permanent and proper repairs to fire main in engine room. Patch is located in the forward engine room lower level near overhead at elbow. LEGACY COMPONENT DESC: Condition
Electrical › Electric Generation Source (service)
Issued 15 April 2002
Resolved
Install protective guard over the front of the flywheel for forward generator. LEGACY COMPONENT DESC: Generator
Lifesaving › Embarkation Appliances/Stations
Issued 15 April 2002
Resolved
Install grates for lifeboats in lifeboat deck.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 April 2002
Resolved
Repair hand rail leading up to forecastle Port side. LEGACY COMPONENT DESC: Deck Rail
Stability › Watertight Integrity
Issued 15 April 2002
Resolved
Install gaskets to vent for covers forward main deck.
Documentation
Issued 3 March 2001
Resolved
Provide valid cargo ship safety radio cert.
Documentation
Issued 3 March 2001
Resolved
Provide medical certificates for entire crew.
Engineering
Issued 2 February 2001
Resolved
Oily Water Separator inoperable/not approved. Vessel granted one-time voyage to Miami with a "conditionally issued" IOPP Cert from class surveyor [name withheld] approved OWS configuration & valid IOPP Cert. reflecting the same IAW MARPOL 73/78 Annex I/16(b)(4)
Construction/Loadline
Issued 2 February 2001
Resolved
4 inch crack IWO aft peak tank & emergency escape trunk. Repair to the satisfaction of Safety Construction Cert. issuing authority_x001C_ IAW SOLAS 60 II/9 (b) _x001C_ Class surveyor issued Condition of Class for 20FEB01.
Accommodation/Occupational Safety
Issued 2 February 2001
Resolved
Marine Sanitation Device has local pitting on fwd port side bulkhead._x001C_ Have tank audio gauged and provide attestation as to integrity of tank to the satisfaction of IOPP Cert. issuing authority IAW 33 CFR 159.7_x001C_
Electrical
Issued 2 February 2001
Resolved
Open breakers on electrical panel breaker box in E/R._x001C_ Install blank breakers in open slots_x001C_ IAW SOLAS 60 II/27 (a)(i)(1)_x001C_
Fire Fighting
Issued 2 February 2001
Resolved
Paint locker has wooden door. _x001C_ Provide appropriate class "A" fire resistant door IAW Safety Construction Cert. issuing authority, prior to departure from the Port of Houston._x001C_ IAW SOLAS 60 II/35 (i)_x001C_
Electrical
Issued 2 February 2001
Resolved
Missing non-conductive matting at electrical switchboard._x001C_ Install NLT 10FEB01_x001C_ IAW SOLAS 60 II/27 (a)(ii)_x001C_
Navigation
Issued 2 February 2001
Resolved
GMDSS maintenance agreement expired. _x001C_ Provide valid agreement prior to departure_x001C_ IAW SOLAS 74 IV/15.6_x001C_ _x001C_
Lifesaving
Issued 2 February 2001
Resolved
Lifeboat lacking 2nd means of propulsion. _x001C_ Provide IAW Safety Equipment Cert. issuing authority, prior to departure_x001C_ from the Port of Houston IAW SOLAS 60 III/11 (a)(vi).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.