MAURY USCG vessel records Sign in
← All vessels

LEGS III

LEGS III is a 1981 offshore supply vessel. The Coast Guard has recorded 40 inspections since 1989, most recently in March 2023, along with 16 deficiencies.

Records from 1989 to 2023. Most recent: inspection, 9 March 2023.

Built
1981
Last inspected
9 March 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8765785 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRA4333
202133
Flag
UNITED STATES
367028570
Maury page id
psix-202133

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (1989–2023)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)78.9 ft × 38.0 ft × 8.0 ft
Registered tonnagegross 194 / net 132
ITC dimensions (L × B × D)78.9 ft × 38.0 ft × 8.0 ft
ITC tonnagegross 277 / net 83
BuilderBLUE STREAK INDUSTRIES · CHALMETTE, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsRecreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it277 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Gross Ton
83 - Convention (Subpart B), Net Ton
132 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2443MMSI 367028570 · active · voluntarily equipped · granted 14 June 2022, expires 14 June 2032
WRA4333MMSI 367028570 · cancelled · voluntarily equipped · granted 7 February 2015, cancelled 4 June 2021 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MICHAEL A Towing Vessel · MISLE 95868 · 18 December 1998 · activity 85059

Inspection history · 40

9 March 2023 Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7648144
20 July 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5190432
24 July 2012 Drydock Exam · Annual Inspection · Administrative Inspection · Examination of Repairs · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4388988
30 October 2008 Deficiency Check · Ballast Water Examination · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3354146
26 July 2007 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3008038
23 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3004823
30 May 2007 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2946006
20 July 2006 COI Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2717919
13 December 2005 MTSA Verification · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2550409
24 May 2004 MTSA Verification · Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2077071
6 March 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1753328
1 May 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1611502
21 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469035
27 June 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389127
16 June 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810015
5 May 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453606
18 December 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 85059
21 July 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 75110
6 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364731
1 May 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375001
23 April 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380487
29 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 881365
7 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363245
17 November 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176152
1 September 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 860642
21 July 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 864251
16 June 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377208
13 April 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432670
17 November 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1132333
8 May 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264450
7 May 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224697
14 February 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238125
24 November 1990 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 990952
13 August 1990 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212493
9 August 1990 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211403
18 May 1990 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920912
24 April 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913707
23 February 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241759
8 September 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889941
16 May 1989 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205311

Deficiency record · 16

Lifesaving › Rescue Boat Equipment › Painter
Issued 22 August 2012 Resolved
Nylon rescue boat harness deteriorated due to exposure to ultraviolet light (sun light) - replace or provide 3rd party report attesting that harness is still within specs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Resolution: New harness purchased.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 22 August 2012 Resolved
Repair fuel reach rod on starboard side
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Resolution: Corrected
Engineering › Sea-water System (primary cooling) › Valve
Issued 22 August 2012 Resolved
Ballast water crossover valves inoperable (from port engine room thru centerline bulkhead to starboard engine room) - repair and prove operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Resolution: corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 August 2012 Resolved
Label all lifesaving devices with name of the vessel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 August 2012 Resolved
Service all ventilation closure devices and prove operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Resolution: Corrected
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 22 August 2012 Resolved
[name withheld] designed to move mem from one vessel to another vessel had internally melted due to welding in the shipyard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 22 August 2012 Resolved
label all motor controls in teh engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 22 August 2012 Resolved
Centerline bulkhead in the engine room at the entrance from the fidley (next to wire run to cabin) had an improper pad weld at the top of the bulkhead. Gouge out. re-weld and NDT the repair. Location is in the top corner (aprox 7' up from engine room deck).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 August 2012 Resolved
Hyd filter holed and leaking fluid onto the deck. Replace
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 22 August 2012 Resolved
Mount PTO (push to operate) kick out controls on the starboard propulsion engine for the jacking system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2012
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 20 July 2006 Resolved
Per NVIC 8-91 vessel hydraulic jacking systems must substantially meet the requirements of 46 CFR 58.30 & 56.30 (which is incorporated by 58.30). Provide third party inspection of all system components, to identify systems as "fail safe" (those with/without counterbalance valves) and any components not rated for maximum system operating pressure. Repair/replace all identified components.
Due 20 July 2007
Resolved 30 October 2008
Resolution: Vessel provided documentation that the hydraulic jacking system meets stated requirements as set forth in letter from [name withheld] engineer.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 24 May 2004 Resolved
PROVIDE FIRE DETECTION SYSTEM IN PORT/STBD ENGINE ROOMS AS REQUIRED BY NVIC 1-78.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 13 December 2005
Lifesaving
Issued 5 May 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Documentation
Issued 16 June 1994 Resolved
OBTAIN A LOADLINE IAW U.S.CODE 5102.
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Lifesaving
Issued 16 May 1989 Resolved
PROVIDE EMBARKATION LADDER.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Documentation
Issued 16 May 1989 Resolved
PROVIDE COAST GUARD APPROVED STABILITY AND OPERATIONAL MANUAL.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.