Records from 1997 to 2026. Most recent: inspection, 29 June 2026.
Documentation record
Registered dimensions (L × B × D)46.3 ft × 20.1 ft × 6.7 ft
Registered tonnagegross 60 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderIOWA MARINE REPAIR CORPORATION · KEOKUK, IA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHILLICOTHE, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
29 June 2026
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8418517
28 May 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8133154
28 October 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8033461
9 August 2024
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7977784
4 April 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7662905
4 April 2023
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7663481
6 April 2022
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7430824
13 February 2021
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7153546
27 January 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6896809
27 January 2020
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6900146
20 November 2019
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6870861
10 October 2019
TPO Audit · Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6829579
21 November 2017
Deficiency Check · MARPOL · DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6313141
4 October 2017
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6288392
17 September 2017
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6274806
25 November 2014
Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5029680
3 April 2014
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4831924
20 December 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4513464
30 August 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4426213
29 November 2011
Deficiency Check · Administration · Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4197006
11 September 2008
DAPI Audit · Deficiency Check · Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3322607
26 December 2006
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2874549
26 December 2006
Uninspected Other · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2874550
20 September 2002
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1678104
22 May 2001
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 290377
1 December 1999
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 435515
13 September 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 186607
20 August 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 419631
23 September 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 408250
19 August 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 407026
3 March 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 753555
1 March 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 191259
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2024
Resolved
The owner or managing operator of the towing vessel must make a request for an amended COI to the cognizant OCMI any time there is a change in ownership. The vessel changed ownership and requires an amended COI.
If selecting the TSMS option, the owner or managing owner must provide the OCMI objective evidence of compliance with the requirements in this subchapter prior to issuance of an amended COI.
***These deficiencies must be cleared to the satisfaction of a Coast Guard marine inspector prior to returning vessel to service. In lieu of Coast Guard attendance, the company may use their Third Party Organization, iTow, to ensure compliance and provide a report to the Coast Guard inspector listed below.****
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 May 2025
Resolution: Vessel completed CG Option COI.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 9 August 2024
Resolved
A towing vessel of less than 300 tons gross that engages in towing on navigable waters of the U.S. must be equipped with a marine radar. The vessel does not have a radar. Install the proper radar equipment or request an exemption under 33 CFR 164.01.
***These deficiencies must be cleared to the satisfaction of a Coast Guard marine inspector prior to returning vessel to service. In lieu of Coast Guard attendance, the company may use their Third Party Organization, iTow, to ensure compliance and provide a report to the Coast Guard inspector listed below.****
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 May 2025
Resolution: Vessel has installed proper radar equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2023
Resolved
Both of the vessel's enigines failed.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 12 April 2023
Resolved 7 April 2023
Resolution: Replaced starter. Conducted sea trial. All Sat. See attached TPO report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2020
Resolved
Ensure all fire damaged wiring on generator number one is repaired and that the generator functions as designed. Generator number one caught fire while dockside on 27JAN2020 due to chaffing on one of the primary leads, causing a short to ground thru the generator casing.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Received letter from TPO accepting the repairs to the number one generator. Company had a local electrician replace the conduit and wiring that was damaged by the fire.
Communications › Alarms/Indicators › General Alarm
Issued 11 September 2008
Resolved
Prove proper operation the Engine Room Fire Alarm indicator light.
Condition: Unknown
Due 11 October 2008
Resolved 22 September 2008
Communications › Alarms/Indicators › General Alarm
Issued 11 September 2008
Resolved
Either change the clear lens to a red one on the existing engineroom general alarm light or install an additional red indictor light. Post a sign for the new red General Alarm alarm light.
Condition: Unknown
Due 11 October 2008
Resolved 22 September 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 December 2006
Resolved
Install lagging on exposed generator exhaust manifold.
Condition: Unknown
Due 27 January 2007
Resolved 23 February 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 December 2006
Resolved
Relocate batteries in the engine room to a safe location from under the electric heater.
Condition: Placed in Improper Service
Due 27 February 2007
Resolved 16 February 2007
Engineering › Steering Gear System › Rudder Bearing
Issued 26 December 2006
Resolved
Install new bushings for the steering system.
Condition: Unknown
Due 15 January 2007
Resolved 16 February 2007
Fire Fighting › Fire Main › Pressure
Issued 26 December 2006
Resolved
Install a strainer on the fire pump sea chest.
Condition: Unknown
Due 15 January 2007
Resolved 16 February 2007