MAURY USCG vessel records Sign in
← All vessels

RAM IV

RAM IV is a 1981 offshore supply vessel. The Coast Guard has recorded 30 inspections since 1990, most recently in July 2015, along with 17 deficiencies and 2 casualty investigations in 2006.

Records from 1990 to 2015. Most recent: inspection, 20 July 2015.

Built
1981
Last inspected
20 July 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8765797 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRA4563
202516
Flag
UNITED STATES
367033540 (licence lapsed)
Maury page id
psix-202516

Inspections, by type

…with no type recorded1
Years with a record 24 calendar years (1990–2015)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it194 - Regulatory (Subpart C or D), Gross Ton
277 - Convention (Subpart B), Gross Ton
132 - Regulatory (Subpart C or D), Net Ton
83 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WRA4563MMSI 367033540 · cancelled · voluntarily equipped · granted 18 June 2016, cancelled 25 June 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 30

20 July 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5190421
17 May 2012 Examination of Repairs · MTSA Verification · Ballast Water Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4313889
20 July 2011 Deficiency Check · Administrative Inspection · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4089023
26 March 2010 COI Inspection · MTSA Verification · Ballast Water Examination · Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3703575
8 July 2009 Re-Inspection · Administrative Inspection · MTSA Verification · Ballast Water Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3529983
7 May 2009 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3469642
15 July 2008 MTSA Verification · Administrative Inspection · Periodic Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3269047
10 May 2007 Re-Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2927974
19 April 2006 MTSA Verification · Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2629325
18 January 2006 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2570279
16 January 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2569066
25 March 2005 MTSA Verification · Hull Examination · Ballast Water Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2319331
8 March 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2020210
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973172
21 January 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1732844
19 March 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1494642
30 January 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376432
1 March 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470550
11 January 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411797
20 February 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375329
16 April 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394720
10 April 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083631
26 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385667
25 April 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457260
21 March 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432783
23 April 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358051
17 November 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1132340
27 March 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952320
11 March 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238336
29 March 1990 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926571

Deficiency record · 17

Construction/Loadline › Structures › Door
Issued 17 May 2012 Resolved
Repair stairwells in port and starbaord engine room as indicated due to corrosion
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2012
Resolution: Corrected
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2012 Resolved
Repair port and starboard bottom at angle at bottom of stairwell
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2012
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 May 2012 Resolved
Repair leaking fuel pipe in port engine room aft bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2012
Resolution: Corrected
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 17 May 2012 Resolved
Provide closure devices fo rgalley vents on port side
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2012
Resolution: Corrected.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2011 Resolved
Stbd E/R bilge pump was not secured to support. Support was also wasted requiring replacement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Resolution: Support was renewed.
Engineering › Bilge Water Management System › Valve
Issued 26 July 2011 Resolved
Stbd E/R bilge suction reach rod was seized and not attached to valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Resolution: Reach rod was repaired.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 26 July 2011 Resolved
Port and Stbd ventilation closures would not provide a tight seal.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Resolution: Ventilation closure gaskets renewed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 July 2011 Resolved
Draft marks and vsl's name were worn.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Resolution: Name and draft marks were re painted.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2011 Resolved
Stbd E/R hydraulic PTO soleniod valve wiring was spliced and not placed inside a junction box.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Resolution: Solenoid wiring was placed inside a J-box.
Lifesaving
Issued 1 March 2000 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District Policy Ltr. dated 12NOV98 "Rescue Boat Requirements on Offshore Supply Vessels" to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Documentation
Issued 11 January 1999 Resolved
Provide on board a Chemical Testing and Employee Assistance Program as required by 46 CFR Part 16.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Engineering
Issued 26 March 1996 Resolved
PROVIDE FLAME SCREEN BOWLS ON BOTTOM OF EACH RACOR FUEL OIL STRAINER ON BOARD.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Deck/Cargo
Issued 26 March 1996 Resolved
OBTAIN AND PLACE THE FOLLOWING ON STBD CRANE: MANUFACTURES DATA PLATE, LOADCHART, BOOM ANGLE INDICATOR.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Documentation
Issued 29 March 1990 Resolved
PROVIDE PROPER DOCUMENTATION OR MANNING WILL BE INCREASED.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Documentation
Issued 29 March 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Documentation
Issued 29 March 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, FIRE CONTROL PLAN AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Documentation
Issued 29 March 1990 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER OR IF ISSUED BY ABS,SUBMIT ABS ISSUED STABILITY LETTER TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990

Casualty record · 2

16 January 2006Routine · role: Involved in a Marine Casualty · activity 2569066
26 November 2006Routine · role: Involved in a Marine Casualty · activity 2832259
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.