Records from 2006 to 2026. Most recent: inspection, 11 February 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 3 December 2025
Resolved
In addition to the immersion suits required under paragraph (a)(1) of this section, each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch in, or assigned to, the station or site at one time. MI observed no immersion suit in the pilothouse.
46 CFR 141.350(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 17 December 2025
Resolution: Additional immersion suit acquired for the pilot house.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI observed open wire in the engine room adjacent to the switchboard.
46 CFR 143.400(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 17 December 2025
Resolution: Dead end wire removed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2025
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. MI observed semi-portable fire extinguisher with wheels not permanently attached to a steel bulkhead.
46 CFR 142.230(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 17 December 2025
Resolution: Semi-portable properly secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI observed battery charger connected to battery with alligator clips located under pilothouse.
46 CFR 143.400(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 17 December 2025
Resolution: Battery charger was removed
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 December 2025
Resolved
The painter must have a float-free link meeting the requirements of part 160, subpart 160.073 of this chapter secured to the end of the painter that is attached to the vessel. MI observed incorrect arrangement of float-free link.
46 CFR 199.175(b)(21)(ii)(C)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 December 2025
Resolved 3 December 2025
Resolution: Operator fixed the hydrostatic release configuration.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 December 2025
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage, including: MI observed charts and publications not up-to-date.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 December 2025
Resolved 3 December 2025
Resolution: Operator downloaded an updated version of charts and publications.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 October 2024
Resolved
In addition to the immersion suits required under paragraph (a)(1) of this section, each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch in, or assigned to, the station or site at one time. Vessel only has 4 of 5 immersion suits that are required to be on board.
46CFR141.350(a)(2)
Action required: 705 - Other - as specified
Resolved 28 October 2024
Resolution: MI received photographic evidence of required suits onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 October 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Vessel only has 3 of 5 required life jackets that have a valid light.
46CFR141.340(g)(1)
Action required: 705 - Other - as specified
Resolved 28 October 2024
Resolution: MIs received photographic evidence of new lights on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2024
Resolved
A towing vessel may not be operated without having
onboard a valid COI issued by the Coast Guard as
required by § 136.202.
A towing vessel subject to this subchapter and choosing
the Coast Guard inspection option must undergo an annual
inspection within 3 months before or after the COI
anniversary date.
Vessel’s window for annual inspection closed on 07OCT24.
Complete inspection prior to towing.
46 CFR 136.200(a) C
46 CFR 147.200
705c
Action required: 705 - Other - as specified
Resolved 21 October 2024
Resolution: MIs conducted COI renewal. Issued temp COI.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 6 September 2023
Resolved
Immersion suits carried on towing vessels must meet the requirements of § 199.70(c) and (d) of this chapter.
Each immersion suit or anti-exposure suit must have a life jacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. All six immersion suites did not have lights attached.
46CFR141.350(4)(b)
46CFR199.70(c)(4)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 19 September 2023
Resolution: MI obsvered approved and operational lights all on six immersion suits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2023
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pressure vessel relief valves.
Twice every 5 years, with no more than 3 years elapsing since last test. Port air receiver pressure relief valve has not been tested.
46CFR143.245(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 19 September 2023
Resolution: Vessel provided evidence of port air receiver PRV test and labeled tanks and valve appropriatley.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2023
Resolved
Crewmember training required by this section must be conducted as soon as practicable, but not later than 5 days after employment.Refresher training must be repeated annually and may be conducted over time in modules covering specific topics. Refresher training may be less comprehensive, provided that the information presented is sufficient to provide employees with continued understanding of workplace hazards. The refresher training of persons subject to this subpart must include the information and training prescribed in this section. Vessel had no record of new crew members conducting the required training as well as capturing all of the required training for all crew members annually.
46CFR140.515(c)(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 19 September 2023
Resolution: O/O provided training log and materials for training new crew members to include, orientation and refresher training.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 6 September 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217. Berthing spaces did not have smoke detection.
46CFR142.330(8)(b)
Action required: 705 - Other - as specified
Due 14 September 2023
Resolved 13 September 2023
Resolution: O/O provided evidence of newly installed smoke detectors in berthing spaces. UL217 approved with a 10 year battery life.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 September 2023
Resolved
The system draws power from two sources. Switchover from the primary source to the secondary source may be either manual or automatic. Fire detection panel had a trouble light that indicated low back up battery power. Operator replaced battery on the spot. All sat.
46CFR142.330(5)
Action required: 10 - Deficiency Rectified
Resolved 6 September 2023
Resolution: Operator replaced batteries on the spot. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved.
Alcohol test strips expired.
46CFR4.06-15(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 19 September 2023
Resolution: O/O provided up to date alcohol testing strips in the appropriate quantity.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 March 2022
Resolved
...all fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturers approved design manual. Found small hole in fire main piping system. Provide repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 7 June 2022
Resolution: The piping was replaced on the fire main where there was a hole, system was tested successfully, All sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 March 2022
Resolved
Each towing vessel must have reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Vessel representative unable to test high cooling water temperature alarms for both the main engines and generators. Provide means to witness testing of alarms to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 7 June 2022
Resolution: Vessel representative was able to test high cooling water temperature alarms for both the main engines and generators. MI verified all alarms were tested successfully, All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 March 2022
Resolved
...operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit...The operator is responsible for the proper operation of the station. Vessel Master did not have a valid commercial radio operators license or permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 7 June 2022
Resolution: Vessel showed proof of the commercial radio operators license, All sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 March 2022
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. Vessels paint locker did not have a 40-B portable fire extinguisher located near the vessels paint locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 7 June 2022
Resolution: Verified that a 40-B portable fire extinguisher was located near the vessels paint locker, All sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 28 March 2022
Resolved
All smoke and fire-detection systems, including detectors and alarms, must be tested. Vessel representative was unable to test fire alarm for engine room space. Provide testing of fire-detection system alarms to the to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 7 June 2022
Resolution: Vessel representative was able to test fire alarm for engine room space successfully, All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 28 March 2022
Resolved
Marine employers shall establish programs for chemical testing of dangerous drugs, vessel was unable to provide proof of enrollment for crew in safety sensitive positions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 7 June 2022
Resolution: Vessel provided proof of enrollment for crew.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 February 2021
Resolved
Vessel could not provide proof of drug testing or enrollment of crew members.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2021
Resolved 3 March 2021
Resolution: The Marine Employer provided documentary proof of pre-emplyment test and enrollment in a random chemical testing program for all crew.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 February 2021
Resolved
Vessel does not have current alcohol test strips that are not expired.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2021
Resolved 24 February 2021
Resolution: Alco test strips were provided. Expiration date is 2/2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 February 2021
Resolved
Vessel is missing life floats for both life bouys and the life float.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2021
Resolved 24 February 2021
Resolution: Both life ring buoys were fitted with floating water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 11 February 2021
Resolved
Life float was found unserviceable and the webbing that attaches the life lines were dry rotted.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2021
Resolved 24 February 2021
Resolution: Company provided an inservice and acceptable life float with a capacity of 4 persons.