MAURY USCG vessel records
← All vessels

DISCOVERY

Built
1981
Last inspected
25 November 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 November 2024
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3315
202663
Flag
UNITED STATES
Maury page id
psix-202663

Documentation record

Registered dimensions (L × B × D)61.8 ft × 26.0 ft × 6.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROWN POINT INDUSTRIES · JEAN LAFITTE, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 30 October 2025 · expires 30 November 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 59 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

25 November 2024 Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8037528
28 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8026081
19 January 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7845122
23 March 2022 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7416380
15 February 2022 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7396473
2 November 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088526
24 July 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6760724
19 July 2019 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6754951
7 January 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6605059
9 January 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6335131
31 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080621
14 November 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6040370
26 October 2016 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6029821
3 August 2016 Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5962034

Deficiency record · 59

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2024 Resolved
Repairs must be inspected by a marine inspector. The following work list item was noted during the vessel's scheduled NDT for leg-to-can’ / ‘can-to-pad’ / and the leg rack lower terminus: -The starboard forward pad was found to have an inset and crack inboard with water inside of it. The pad was removed from the leg for repair. Repair pad and NDT. Once reattached to the leg, NDT prior to dry dock credit. 46 CFR 176-20-5 (Old T)
Action required: 705 - Other - as specified
Due 5 December 2024
Resolved 13 December 2024
Resolution: The starboard forward pad inset/crack was repaired and NDTd. The pad was reattached to the leg and NDTd. Item cleared - see narrative for additional details.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 October 2024 Resolved
Except Extensions authorized, each vessel shall be hauled out and made available for examination. Vessel missed dry dock, internal structure exam, and air receiver date. 705 - May not operate commercially.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2024
Resolution: The vessel’s DD/ISE was completed, and credit given on 13DEC24.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 October 2024 Resolved
Operational limits are determined by the local OCMI and described on the COI. Vessel missed crane test date required every 60 months as outlined in COI. 705 - May not operate commercially.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 November 2024
Resolution: Witnessed satisfactory crane load test. See narrative for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2024 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a); vessel did not have hand pump in addition to direct power pump. 46 CFR 182.25-10(a) Old "T"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2024
Resolution: Bilge pump installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2024 Resolved
Marine Inspector shall examine to the extent necessary to determine safe electical condition; cables improperly supported and splices improperly made. 46 CFR 176.25-25 Old "T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 February 2024
Resolution: All issues corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 February 2024 Resolved
Vessel is to undergo annual inspection within 3 months before or after each anniversary; vessel missed 2023 annual. 46 CFR 176.500
Action required: 10 - Deficiency Rectified
Resolved 5 February 2024
Resolution: Annual completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2024 Resolved
Ring buoys must be marked with type II retro-reflective material; tape was no longer reflective. 46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 February 2024
Resolution: Tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 February 2024 Resolved
Each lifefloat must meet 160.010; lifefloat retro tape was no longer reflective 46 CFR 160.027-2(a) 46 CFR 160.010-4(p)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 February 2024
Resolution: Tape replaced
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2022 Resolved
As appropriate, vsl must carry adequate and up to date charts; Vessel did not have charts onboard with up to date corrections.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2022
Resolution: Vessel replaced charts with up to date charts.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 March 2022 Resolved
Each lifefloat must be fitted with two (02) paddles; Each lifefloat had (01) paddle.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2022
Resolution: Vessel added extra paddle to each life float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 23 March 2022 Resolved
46 CFR 177.1020: Each window, porthole, and its means of attachment to the deckhouse must be capable of withstanding the max load from wind or wave expected; Galley weathertight hatch had pinhole open to environment
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2022
Resolution: Vessel sealed window on weathertight door with a steel plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 March 2022 Resolved
46 CFR 182.10-1(a)Old "T": Auxiliary machinery shall be suitable in type and design for the purpose intended; water heater was not permanently mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2022
Resolution: Vessel permanently mounted water heater.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 March 2022 Resolved
An independent modular smoke detector must contain an independent power source; Battery was dead in detector in crew berthing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2022
Resolution: Vessel replaced smoke detector batteries and appropriately mounted the smoke detector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 November 2020 Resolved
All vessels must have navigation lights that are in compliance with the international and inland navigation rules. The upper masthead and anchor light lens was obstructed by paint spray.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
Resolution: The forward masthead light lens was replaced and the remaining light lenses cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2020 Resolved
Exhaust piping shall be gas-tight throughout its length. Both port and starboard generator exhaust piping was not gas-tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
Resolution: Flexible exhaust joints for BSSDG's renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 November 2020 Resolved
Each life float must be secured to the vessel by a float free link. Float free link should be secured to the painter at one end and secured to vessel at the other end. The vessel's float free link was broken and not properly attached to the vessel and painter line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2020 Resolved
At each subsequent inspection, the marine inspector shall inspect all life saving equipment to determine serviceability. Aft and forward ring buoy on main deck, portside ring buoy on 01 deck lines, starboard life float waterlight lines, and an accommodation space life jacket was not in serviceable condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 November 2020 Resolved
At each subsequent inspection, the rescue boat shall be tested. The rescue boat had difficulty starting and the engine running erratically.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
Resolution: The outboard had mud and debris cleared from the cooling system and MI witnessed satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 November 2020 Resolved
At each subsequent inspection, all firefighting equipment shall be inspected and all deficiencies shall be corrected. Paint locker CO2 line was wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: The wasted CO2 hose was replaced in kind with new hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2020 Resolved
At each subsequent inspection, all machinery equipment shall be in proper operating condition and no fire hazards exist. Cracked hydraulic hoses were found on all external hydraulic jacking system and crane hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: All hydraulic hoses in question were replaced in kind with new hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 November 2020 Resolved
All emergency exits shall be marked on both sides, "emergency exit, keep clear". Both port and starboard Engine Room emergency markings were faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2020 Resolved
The pressure vessel relief valve shall be tested every five years. The Engine Room pressure vessel relief valve testing or replacement date is unknown and shall be bench tested or replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: Relief valve was replaced in kind with new valve and identification tag.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 November 2020 Resolved
Every vessel shall be fitted with a suitable compass. The current compass was calibrated in October 2008. Calibrate the magnetic compass and issue new deviation card to ensure its suitability.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: Vessel was swung and magnetic compass was calibrated. New compass deviation issued and posted on the Bridge.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 January 2019 Resolved
EPIRB tests are not being properly logged.
Action required: 10 - Deficiency Rectified
Resolved 7 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2019 Resolved
Lifebuoy floatlight betteries are expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 January 2019 Resolved
Replace paint locker extinguisher hose.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 January 2019 Resolved
Replace two (2) ripped lifejackets. Total persons allowed not to exceed 10 until replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2019 Resolved
Replace all 1/2" hydraulic hoses on stern leg (total of 6 hoses).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 January 2019 Resolved
Provide and install cover for pantry light.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2019 Resolved
Air receiver relief valve not operating when pressed up. Test, repair, or replace air receiver relief valve.
Action required: 10 - Deficiency Rectified
Resolved 7 January 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2019 Resolved
Repair oil leaks and clean windings on port SSDG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2019
Resolved 11 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 7 January 2019 Resolved
Make weld repairs to engine room vent trunks.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 January 2019 Resolved
Make operable emergency lights on Bridge.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 January 2019 Resolved
Replace fuel lines on stbd main engine (2), stbd SSDG (3), and the port SSDG oil gauge hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 January 2019 Resolved
Prove proper operation of fire pump to achieve 60 psi with one hose nozzle open.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2019
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 9 January 2018 Resolved
LIftboats are required to have an anemometer onboard according to CG-543 Policy Letter 07-02.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Anemometer was placed on bridge.
Construction/Loadline › Penetrations › Weld
Issued 9 January 2018 Resolved
Demonstrate water tight integrity for hydraulic oil fill cap on stbd deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Replaced cap.
Lifesaving › Lifefloat › Markings
Issued 9 January 2018 Resolved
Clean both life floats, properly mark and provide proof of ID plate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Floats were sent out for servicing and certification.
Lifesaving › Lifefloat › Paddle
Issued 9 January 2018 Resolved
Provide oars for stbd life float.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Oars were provided.
Lifesaving › Lifefloat › Float-free Link
Issued 9 January 2018 Resolved
Provide proper weak link for each life float based on life float capacity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Weak links replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 January 2018 Resolved
Replace bracket for port ring buoy light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Replaced bracket.
Lifesaving › Lifefloat › Float Free
Issued 9 January 2018 Resolved
Resplice port life float line to facilitate proper float free release.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Line was properly spliced.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 January 2018 Resolved
Secure deep freeze to prevent shifting at sea.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Freezer was secured to deck
Construction/Loadline › Structures › Ventilators
Issued 9 January 2018 Resolved
Make repairs to hole in port engine room air intake ducting.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Holes were welded shut then painted.
Engineering › Lubricating Oil Service System › Hose
Issued 9 January 2018 Resolved
Replace two (2) wasted hydraulic hoses on stbd leg.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Wasted hoses were replaced.
Electrical › Electric Supply System (service) › Cable
Issued 9 January 2018 Resolved
Support electrical cables with metal wire ties or brackets in engine room.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Metal wire ties and hangers were installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 9 January 2018 Resolved
Repair fuel reach rod on stbd side to fully operational.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Valve repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 9 January 2018 Resolved
Repair exhaust lagging on stbd side main engine where exposed.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Lagging replaced.
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 9 January 2018 Resolved
Install guard on hydraulic lube oil tank sight glass.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Guard installed.
Engineering › Bilge Water Management System › Pump
Issued 9 January 2018 Resolved
Repair automatic bilge pump float.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Float switch replaced.
Engineering › Fuel Oil Service System › Filter
Issued 9 January 2018 Resolved
Repair fuel leak on port generator.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Fuel leak repaired.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 January 2018 Resolved
Adjust watertight hatch between port and stbd engine room to fully dog down.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Hatch adjusted.
Fire Fighting › Fire Main › Condition
Issued 9 January 2018 Resolved
Repair wasted/leaking check valve on fire plug.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2018
Resolved 7 March 2018
Resolution: Check valve replaced.
Fire Fighting › Fire Main › Condition
Issued 9 January 2018 Resolved
Properly label fire main pump controllers.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 7 March 2018
Resolution: Controls properly labeled.
Communications › Radio Communications › Emergency Source of Power
Issued 14 November 2016 Resolved
Prove operation of radio on reserve power to satisfaction of marine inspector IAW 47CFR80 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2016
Resolution: Verified renewal of battery.
Lifesaving › Lifebuoys › Serviceable
Issued 14 November 2016 Resolved
Provide serviceability to stbd fwd lifering IAW 46CFR180.70 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2016
Resolution: Verified renewal of life line.
Engineering › Fuel Oil Service System › Hose
Issued 14 November 2016 Resolved
Provide protection of flexible hoses from mechanical wear on port and stbd main engine. IAW46CFR56-50.75 by 19NOV16
Due 19 November 2016
Resolved 18 November 2016
Resolution: Verified protection of lines.
Engineering › Fuel Oil Service System › Hose
Issued 14 November 2016 Resolved
Renew or prove serviceability to flexible fuel hoses on stbd main engine to satisfaction of marine inspector IAW 46CFR56.50-75 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2016
Resolution: Verified replacement of hoses.
Engineering › Generator (propulsion/auxiliary-electric) › Coil
Issued 14 November 2016 Resolved
Remove excess oil buildup from port generator windings IAW 46CFR182.20 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2016
Resolution: Verified cleanup of coils.

Recorded names · 1

SUPERIOR RESPECT (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.