← All vessels
R/V GEOEXPLORER
R/V GEOEXPLORER is a 1982 research vessel. The Coast Guard has recorded 40 inspections since 1985, most recently in April 2016, along with 52 deficiencies and 1 casualty investigation in 2009.
Records from 1985 to 2016. Most recent: inspection, 5 April 2016.
- Built
- 1982
- Last inspected
- 5 April 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 52 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
642135
8107921 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA6456
202897
Flag
VANUATU
338339000, 369551000 (licence lapsed)
Maury page id
psix-202897
Inspections, by type
…with no type recorded7
Years with a record
26 calendar years (1985–2016)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it295 - Regulatory (Subpart C or D), Gross Ton
541 - Convention (Subpart B), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
162 - Convention (Subpart B), Net Ton
541 - Convention (Subpart B), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
162 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDA6456MMSI 369551000 · expired · compulsorily equipped · granted 22 September 2011, cancelled 12 February 2022
WBHOMMSI 338339000 · cancelled · compulsorily equipped · granted 25 January 2001, cancelled 25 February 2004 · licensed under a name not among this hull’s recorded names (not shown)
WRA8558MMSI not assigned · cancelled · compulsorily equipped · granted 25 June 1996, cancelled 17 February 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 40
5 April 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5844204
12 August 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4952702
12 June 2014
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4886707
17 January 2012
ORV Letter of Designation
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4225791
8 January 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4221361
8 December 2010
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3907039
18 March 2010
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3698211
29 December 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4152782
7 May 2008
ORV Letter of Designation
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3201018
2 February 2008
Uninspected Other · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3134682
27 April 2007
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2937922
3 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2869300
12 January 2006
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2565858
26 March 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2031775
25 April 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1785250
8 January 2002
Uninspected Other
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1476546
16 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1076770
14 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122594
29 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115724
24 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114271
18 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184739
9 June 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 876872
7 March 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432803
21 February 1993
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836079
20 May 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1260440
3 April 1992
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1256580
22 January 1992
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382471
20 August 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1251657
5 August 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 942534
2 March 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1269605
28 February 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 908756
31 December 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921994
16 March 1990
Drydock Extension · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902843
23 October 1989
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 894168
21 March 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209636
3 March 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1197081
26 February 1988
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1033313
29 January 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320167
3 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994787
16 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981130
Deficiency record · 52
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 12 June 2014
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 12 June 2014
Resolved
The one (1) Nigerian AB and two (2) Ghanaian ABs (Nigerian/Ghanaian/Ghana) serving onboard are non-U.S. Citizens in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Personnel › Certificates/Documents/Licenses › MMD, Ordinary Seaman
Issued 12 June 2014
Resolved
The Ordinary Seaman (Ghanaian) serving onboard is a non-U.S. Citizen in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Personnel › Certificates/Documents/Licenses › MMD, Wiper
Issued 12 June 2014
Resolved
The two (2) (Ghanaian/Nigerian) oilers serving onboard are a non-U.S. Citizen in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 12 June 2014
Resolved
The second mate (Nigerian) serving onboard is a non-U.S. Citizen in violation of 46 USC 8103(b) and 46 CFR 15.720.
Documentation
Issued 26 March 2004
Resolved
Vessel operated with expired R/V designation letter.
Accommodation/Occupational Safety
Issued 3 April 1992
Resolved
INSTALL A CISTERN TANK (WATER TANK) TO THE TOILET LOCATED IN THE LAUNDRY ROOM IN ORDER TO MAKE THE TOILET FLUSHABLE.
Lifesaving
Issued 3 April 1992
Resolved
ENSURE THAT BOTH LIFERAFTS ABOARD VESSEL ARE SERVICED BY 01MAY92 IN AN APPROVED USCG LIFERAFT SERVICING FACILITY IN THE PRESENCE OF A USCG INSPECTOR OR REPLACE BOTH RAFTS WITH TWO RECENTLY SERVICED LIFERAFTS.
Construction/Loadline
Issued 3 April 1992
Resolved
INSTALL OPERABLE BILGE ALARM SENSOR LOCATED IN FORWARD ENGINE ROOM TUNNEL.
Accommodation/Occupational Safety
Issued 28 February 1991
Resolved
REMOVE EXCESSIVE ACCUMULATION OF DEBRIS TO PERMIT UNOBSTRUCTED ACCESS TO MACHINERY SPACE STACK VENT DAMPERS.
Fire Fighting
Issued 28 February 1991
Resolved
UPDATE VESSEL FINE CONTOUR PLAN TO REFLECK CURRENT AS IS CONDITION OF VESSEL.
Accommodation/Occupational Safety
Issued 28 February 1991
Resolved
REMOVE EXCESSIVE ALLUMINATION OF DEBRIS IN MACHINERY SPACE WALKWAY WHICH IMPAIRS ACCESS TO BOW THRUSTER MOTOR.
Electrical
Issued 28 February 1991
Resolved
PROPERLY BAND AND SECURE LOOSE ELECTRICAL CABLES IN BRIDGE NAVIGATION ROOM AND COMPUTER ROOM.
Accommodation/Occupational Safety
Issued 28 February 1991
Resolved
FREE UP STICKY ESCAPE SCUTTLE IN AFTER STEERING COMPARTMENT.
Lifesaving
Issued 28 February 1991
Resolved
REPOSITION LIFTRAFT WEAKLINK AND PAINTER 70 CRADLE AS INDICATED ON INSTALLATION DRAWING ON RAFT CANISTER.
Lifesaving
Issued 28 February 1991
Resolved
CONDUCTED FIRE AND ABANDONSHIP DRILL WITHIN 24 HOURS OF DEPARTURE FROM DARWIN. LOG RESULTS OF SAME AND SUBMIT COPY OF LOG TO [name withheld].
Fire Fighting
Issued 28 February 1991
Resolved
PROPERLY BRACKET AND MOUNT ALL PORTABLE FIRE EXTINGUISHERS.
Electrical
Issued 28 February 1991
Resolved
PROVIDE EVIDENCE THAT USCG HAS APPROVED ELECTRICAL PLANS FOR CURRENT INSTALLATION OF COMPUTER ROOM ELECTRICAL WIRING & EQUIPMENT, AND NAVIGATIONROOM ELECTRICAL WIRING AND EQUIPMENT.
Electrical
Issued 28 February 1991
Resolved
REMOVE EXTENSION CORD TAPPED INTO OUTLET IN LAUNDRY ROOM.
Electrical
Issued 28 February 1991
Resolved
MAKE OPERABLE GENERATOR #3 PARALLEL CAPABILITY.
Electrical
Issued 28 February 1991
Resolved
PROPERLY HARD WIRE VENTILATION BLOWER LOCATED BEHIND MAIN SWITCHBOARD.
Fire Fighting
Issued 28 February 1991
Resolved
MAKE PYROTRONICS FIRE DETECTION SYSTEM ALARM AUDIBLE IN MAIN DECK CONTROL CABINET AND BRIDGE CONSOLE.
Electrical
Issued 28 February 1991
Resolved
MAKE OPERABLE ENGINE ROOM GENERAL ALARM CONTACT MAKER.
Electrical
Issued 28 February 1991
Resolved
PROVIDE GENERAL ALARM BELLS SUFFICIENT TO BE HEARD ABOVE NOISE OF AFT DECK CABLE MACHINERY, AND GENERAL ALARM LIGHT, ABOVE AFT DECK CABLE MACHINARY AREA.
Electrical
Issued 28 February 1991
Resolved
PROVIDE ON BOARD AN ACCURATE MEANS OF DETERMINING GENERATOR PRIME MOVER RPM. SET GENERATOR OVERSPEED TRIPS NOT TO EXCEED 2000 RPM.
Electrical
Issued 28 February 1991
Resolved
MAKE OPERABLE COMPUTER ROOM GENERAL ALARM BELL
Engineering
Issued 28 February 1991
Resolved
INSTALL MISSING GUARDS OVER PORT AND STBD MAIN DIESEL ENGINE CRANKSHAFTS.
Electrical
Issued 28 February 1991
Resolved
TEST AND CONFIRM SATISFACTORY OPERATION OF MAIN GENERATOR #1, #2 AND #3 LOWLUBE OIL PRESSURE SHUT DOWNS.
Lifesaving
Issued 28 February 1991
Resolved
PROVIDE UL MARINE STANDARD PORTABLE FUEL TANKS FOR ZODIAC RESCUE CRAFT.
Construction/Loadline
Issued 28 February 1991
Resolved
REMOVE PLASTIC SIGHT TUBES AND NON AUTOMATICALLY CLOSING VALVES ON FUEL TANK #4. RUDDER COMPARTMENT ALLEYWAY. BLANK SAME OR PROVIDE HEAT RESISTANT PROTECTOR GLASS WITH AUTOMATICALLY CLOSING VALVES.
Engineering
Issued 28 February 1991
Resolved
REINSTALL MISSING SHEET METAL SHEATHING ON STBD EXHAUST UPTAKE STACK.
Deck/Cargo
Issued 28 February 1991
Resolved
INSTALL CHAIN GUARD OVER SONAR CABLE SPOOL CHAIN & SPROCKET.
Electrical
Issued 28 February 1991
Resolved
PROVIDE PROPER BATTERY BOXES FOR RADIO AND NAVIGATION INSTRUMENT BATTERIES.
Engineering
Issued 28 February 1991
Resolved
PROVIDE EVIDENCE OF USCG APPROVAL OF CONVERSION OF #4 PORT AND STBD_x001C_ POTABLE WATER TANKS TO FUEL TANKS.
Documentation
Issued 28 February 1991
Resolved
PROVIDE ON BOARD COPY OF USCG STABILITY LETTER DATED 1 JULY 1982.
Unknown
Issued 16 March 1990
Resolved
ENSURE PROPER OPERATION OF PILOT HOUSE ENGINE ROOM VENTILATION SHUTDOWN.
Unknown
Issued 16 March 1990
Resolved
PROVIDE AND POST THE OPERATING INSTRUCTIONS AND DIAGRAM FOR THE STEERING SYSTEM.
Unknown
Issued 16 March 1990
Resolved
PROVE PROPER OPERATION OF CENTERLINE MAIN ENGINE REMOTE SHUTDOWN AND OVERSPEED TRIP.
Unknown
Issued 16 March 1990
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR. UNTIL SEPARATOR IS OPERATIONAL ALL OILY BILGE WATER MUST EITHER BE RETAINED ON BOARD OR PUMPEDTO A RECEPTION FACILITY.
Unknown
Issued 16 March 1990
Resolved
PROVE PROPER OPERATION OF SHIP SERVICE GENERATOR ALARMS AND REVERSE POWER RELAYS.
Unknown
Issued 16 March 1990
Resolved
PROVIDE APPROVED AUTOMATION TEST PROCEDURE FOR THE ENGINEERING MACHINERY.
Unknown
Issued 16 March 1990
Resolved
ENSURE PORTABLE FIRE EXTINGUISHERS RECEIVE REQUIRED ANNUAL SERVICING. PROVIDE SERVICING REPORT FOR THE PORTABLE EXTINGUISHERS.
Unknown
Issued 16 March 1990
Resolved
PROVE PROPER OPERATION OF PYR-A-LARM SYSTEM AND PROVIDE SYSTEM DIAGRAM.
Unknown
Issued 16 March 1990
Resolved
PROVIDE GENERAL ALARM BELL TO BE LOCATED IN THE COMPUTER SPACE ON THE NO. 1 LEVEL.
Lifesaving
Issued 3 March 1989
Resolved
PROVIDE IMMERSION SUITS FOR PERSONNEL OTHER THAN THE CREW WHEN OPERATING INTHE ZONES REQUIRING SUITS.
Documentation
Issued 16 February 1985
Resolved
OBTAIN AMERICAN BUREAU OF SHIPPING LOADLINE ENDORSEMENT.
Electrical
Issued 16 February 1985
Resolved
PROVIDE WIRING DIAGRAMS FOR MOTOR CONTROLLERS IN ACCORDANCE WITH 46 CFR 111.70-3(H)(2).
Engineering
Issued 16 February 1985
Resolved
PROVIDE MAIN ENGINE SHUTDOWNS FOR UNATTENDED ENGINE ROOM.
Electrical
Issued 16 February 1985
Resolved
REPAIR AND TEST OVERSPEED PROTECTION FOR PORT NUMBER 1 GENERATOR.
Navigation
Issued 16 February 1985
Resolved
TEST STEERING GEAR ALARM SYSTEM.
Engineering
Issued 16 February 1985
Resolved
REPAIR AND TEST OVERSPEED PROTECTION FOR STARBOARD MAIN ENGINE.
Electrical
Issued 16 February 1985
Resolved
DEMONSTRATE REVERSE CURRENT RELAY PROTECTION FOR GENERATORS IN ACCORDANCE IWTH 46 CFR 111.12-11(F).
Casualty record · 1
29 December 2009Routine · role: Involved in a Marine Casualty · activity 4152782
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.