← All vessels
SPIRIT OF GRACE
SPIRIT OF GRACE is a 1945 unclassified. The Coast Guard has recorded 105 inspections since 1989, most recently in June 2008, along with 131 deficiencies and 1 operational control.
Records from 1989 to 2008. Most recent: inspection, 8 June 2008.
- Built
- 1945
- Last inspected
- 8 June 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 105
- Deficiencies
- 131 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
642140
8037815 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
KDVG
202902
Flag
UNITED STATES
366554000 (licence lapsed)
Maury page id
psix-202902
Inspections, by type
…with no type recorded59
Years with a record
13 calendar years (1989–2008)
The 105 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Tonnage as PSIX records it3813 - Regulatory (Subpart C or D), Gross Ton
2133 - Regulatory (Subpart C or D), Net Ton
2133 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCX3499MMSI 366554000 · cancelled · compulsorily equipped · granted 27 January 2007, cancelled 16 June 2008
KDVGMMSI 366554000 · expired · compulsorily equipped · granted 8 August 1994, cancelled 9 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 105
8 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3457299
11 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3184537
2 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3176117
14 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3164735
23 April 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2913551
22 January 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1990734
14 June 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 25619
9 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 719744
4 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 177715
26 September 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1134485
26 June 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1085644
27 December 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1184638
14 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 882695
11 September 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880960
15 August 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871873
19 October 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 670741
13 October 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 497177
14 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 670743
8 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 149605
8 September 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865291
7 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 36349
19 August 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 452782
19 August 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 511122
27 July 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 670742
3 July 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 288
29 June 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 140146
9 June 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 66423
6 June 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012406
3 June 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861678
2 June 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 508062
31 May 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 23333
31 May 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170775
29 May 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 509566
17 May 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 506650
11 May 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 670738
17 April 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 20858
14 April 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 366242
14 April 1994
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 856878
8 April 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 862038
6 April 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 173988
4 April 1994
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166330
1 September 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 829204
21 June 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 522136
1 June 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 670739
25 May 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 670740
24 May 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401711
6 May 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 83501
6 May 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 450618
22 April 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 453546
16 April 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 131948
16 April 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 670737
16 April 1993
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 829616
28 March 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 447652
14 January 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 504518
14 January 1993
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 825760
12 January 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 356552
24 November 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138875
12 November 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962117
28 October 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137198
17 August 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249631
11 August 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263636
27 March 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262216
21 March 1992
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 530826
5 March 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 132276
3 March 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316811
18 February 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 480830
7 January 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1258621
26 October 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 935418
26 October 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1251028
23 October 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 936736
15 October 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 461481
6 September 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945596
29 August 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 447534
21 August 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941053
15 August 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 227461
15 July 1991
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249773
14 July 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1248207
18 June 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1197523
17 June 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 344362
17 June 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1200610
28 May 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 444683
30 April 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 471930
22 April 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919038
17 April 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 911717
6 March 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 932978
25 February 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212689
25 February 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227042
29 January 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919192
31 October 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 927679
23 October 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234399
9 September 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 519685
13 August 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 531287
13 August 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 904081
25 June 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 501163
4 June 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 520212
20 April 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220927
10 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 506433
13 March 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 468188
13 March 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 530447
2 March 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227784
23 February 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 522246
22 February 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214284
1 February 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213058
31 October 1989
Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1011010
24 October 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 510542
Deficiency record · 131
Electrical
Issued 3 June 1994
Resolved
PRIOR TO 31OCT94, SUBMIT PLANS FOR NEW DRIP PROOF OVERHEAD ENGINEROOM LIGHTFIXTURES, IN ACCORDANCE WITH 46 CFR SUBCHAPTER J.
Electrical
Issued 3 June 1994
Resolved
PRIOR TO 31OCT94, INSTALL NEW ENGINEROOM OVERHEAD LIGHT FIXTURES IN ACCORDANCE WITH COAST GUARD APPROVED PLANS.
Fire Fighting
Issued 3 June 1994
Resolved
PRIOR TO DEPARTURE FROM SAN FRANCISCO BAY, CA., DEMONSTRATE PROPER OPERATION OF MAIN (DC) FIRE PUMP.
Electrical
Issued 31 May 1994
Resolved
PRIOR TO DEPARTURE FROM SAN FRANCISCO BAY, CALIFORNIA, OR 14 JUNE 1994, WHICHEVER OCCURS FIRST, PROPERLY INSTALL ENGINEROOM OVERHEAD LIGHTING IN ACCORDANCE WITH 46 CFR SUBCHAPTER J TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Navigation
Issued 14 April 1994
Resolved
VSL. MISSING CURRENT COMPASS DEVIATION TABLE.
Fire Fighting
Issued 14 April 1994
Resolved
COMPLETE PERMANENT REPAIRS TO MAIN DECK FIRE MAIN - THIS MEANS "COMPLETE RENEWAL" - NO LATER THAN 31OCT94.
Fire Fighting
Issued 14 April 1994
Resolved
PROVIDE APPROVED WELDING PROCEDURES FOR REPAIRS MADE TO FIRE MAIN, NO LATERTHAN 20APR94 - MUST BE AT LEAST TO MILSPEC STND'S.
Lifesaving
Issued 14 April 1994
Resolved
COMPLETE PERMANET REPAIRS TO STB L/B GUDGEON/PINTLE TO SATISFACITON OF COGNIZANT [name withheld] 31OCT94.
Construction/Loadline
Issued 16 April 1993
Resolved
COMPLETE INTERNAL STRUCTURE EXAM OF #4C (FUEL OIL) TANK.
Electrical
Issued 24 November 1992
Resolved
PROVIDE A MANUAL RELEASE OF THE FIRE FIGHTING SYSTEM ON THE CONTAINERIZED GENERATOR IAW WITH G-MTH LETTER 46-111.10 DATED JULY, 6 1992 OR REMOVE THE CONTAINERIZED GENERATOR FM THE VESSEL. CURRENT TRIP ALLOWED WITH 6 15LB CO2'S STOWED NEAR CONTAINERIZED GENERATOR.
Engineering
Issued 12 November 1992
Resolved
REMOVE EPOXY AND MAKE PERMANENT REPAIRS TO LOWER L/O COOLER ENGINE ROOM, STBD SIDE.
Unknown
Issued 12 November 1992
Resolved
COMPLETE INTERNAL STRUCTURAL EXAM. HAVE THE FOLLOWING SPACES INSPECTED BY A CG MARINE INSPECTOR: FORE PEAK, #5 DB, (#4P, S&C), (#3 P&S), (#2 P&S), (#1 P&S) AND AFT PEAK. THE FOLLOWING TANKS WERE INSPECTED AT DRYDOCK: FORE DEEP, #2 & 3C.
Construction/Loadline
Issued 12 November 1992
Resolved
CLEAN ENGINE ROOM BILGES AND HAVE INSPECTED AS PART OF INTERNAL STRUCTURAL EXAM, INCLUDING BILGE INJECTION STRAINER.
Lifesaving
Issued 28 October 1992
Resolved
PROVIDE VSL WITH 6 MORE IMMERSION SUITS AND 1 MORE LIFE JACET, VESSEL IS LIMITED TO THE REQUIRED CREW ONLY AND MAY NOT CARRY THE 7 PERSONS IN ADDITION TO THE CREW UNTILL THIS ITEM IS COMPLETED.
Unknown
Issued 28 October 1992
Resolved
SERVICE AND CALIBRATE OR REPLACE 3 (AFT) AIR FLASH PRESSURE GAUGES.
Accommodation/Occupational Safety
Issued 28 October 1992
Resolved
INSTALL A PERMANENT DOOR TO RESTRICT ACCESS TO REAR OF EMERGENCY SWITCHBOARD IAW 46 CFR 111.30-1C.
Documentation
Issued 28 October 1992
Resolved
PROVIDE AND MAINTAIN ON BOARD THE ORIGINAL TRIM AND STABILITY BOOK, WITH THE APPROVAL DATE STAMPED 27 OCT 1989.
Electrical
Issued 28 October 1992
Resolved
INSTALL EXPLOSION PROOF LIGHT FIXTURE AND JUNCTION BOX IN PAINT LOCKER.
Construction/Loadline
Issued 28 October 1992
Resolved
PROVE OPERATION OF FWD BILGE PUMP.
Electrical
Issued 28 October 1992
Resolved
INSTALL PERMANENT BLANKS OVER UNUSED FUSE CONTACTS ON EMERGENCY SWITCHBOARD.
Navigation
Issued 28 October 1992
Resolved
INSTALL APPROVED DUAL FILEMENT SIDE LIGHTS TO COMPLY WITH COLREGS AND DUAL ALARMS IN NAVIGATION PANEL.
Unknown
Issued 28 October 1992
Resolved
REPLACE ACORN TYPE FOG APPLICATORS.
Engineering
Issued 28 October 1992
Resolved
INSTALL A PERMANENT SOLID COVER PLATE OVER EMERGENCY GENERATOR/MOTOR COUPLING.
Electrical
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION PROVE PROPER OPERATION OF EMERGENCY GENERATOR_x001C_ ELECTRICAL METERS
Unknown
Issued 26 October 1991
Resolved
REPLACE PVC PIPING ON FRESH WATER UNIT SUPPLY AND BRINE OVERBOARD LINES WITH METALLIC PIPING.
Engineering
Issued 26 October 1991
Resolved
RENEW CORRODED PIPING ON RAW WATER SYSTEM FOR BOTH S/S GENERATOR J/W COOLERS.
Electrical
Issued 26 October 1991
Resolved
REPLACE ALL HARD WIRED "SO" CABLES ON A/C DISTRIBUTION PANELS WITH CABLES OF AN APPROVED TYPE.
Lifesaving
Issued 26 October 1991
Resolved
CONDUCT WEIGHT TEST OF STBD LIFEBOAT.
Electrical
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION REMOVE ALL ELECTRICAL EXTENTION CORDS BEING USED TO PROVED A/C POWER THROUGH OUT VESSEL.
Lifesaving
Issued 26 October 1991
Resolved
PROIR TO CERTIFICATION PROVIDE ONE RING BOUY
Accommodation/Occupational Safety
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION PROVE OPERATION OF SUPPLY VENTILATION TO _x001C_ ACCOMODATIONS.
Construction/Loadline
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION REINSTALL BOLTED ACCESS COVER BETWEEN ENG RM UPPER LEVEL AND NO 3 CARGO HOLD.
Electrical
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION INSTALL COVERS ON ALL OPEN ELECTRICAL JUNCTION BOXESTHROUGH OUT VESSEL.
Electrical
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION INSTALL GLOBES AND GUARDS ON ALL LIGHT FIXTURES.
Engineering
Issued 26 October 1991
Resolved
PROIR TO CERTIFICATION LABLE EMERGENCY GENERATOR FUEL OIL TANK SHUT OF_x001C_ VALVE.
Electrical
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION REMOVE TEMPORARY WIRE CONNECTION ON GENERAL ALARM_x001C_ BATTERY.
Accommodation/Occupational Safety
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION INSTALL COAMING ON CARGO HOLD 4 TO MAIN DECK LEVEL_x001C_ DOOR.
Lifesaving
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION CHANGE OUT FUEL OIL IN MOTOR LIFEBOAT.
Lifesaving
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION RENEW CONDENSED MILK IN BOTH LIFEBOATS.
Fire Fighting
Issued 26 October 1991
Resolved
PRIOR TO CERTIFICATION PROVE PROPER OPERATION OF DIESEL DRIVEN FIRE PUMP.
Fire Fighting
Issued 26 October 1991
Resolved
SUBMIT FOR APPROVAL INSTALLATION DRAWINGS ON DIESEL DRIVEN FIREPUMP.
Lifesaving
Issued 26 October 1991
Resolved
INSTALL A CG APPROVED LIFERAFT ON PORT SIDE OF VESSEL.
Unknown
Issued 26 October 1991
Resolved
RENEW CORRORED PIPING IN AREA OF SANITARY SYSTEM TO REEFER CONDENSER SUPPLYCROSS CONNECT PIPING.
Accommodation/Occupational Safety
Issued 26 October 1991
Resolved
PROVE OPERATION OF ENGINE ROOM SUPPLY VENTILATION.
Engineering
Issued 26 October 1991
Resolved
INSTALL PROPER INSULATION ON EMERGENCY GENERATOR EXHAUST PIPING.
Electrical
Issued 17 April 1991
Resolved
PROVIDE PLANS AND REPLACE EMERGENCY GENERATOR ONCE PLANS APPROVED FOR LARGER GENERATOR CAPABLE OF POWERING EMERGENCY FIRE PUMP AS PER 46 CFR 95.10-5(h). OR PROVIDE DOCUMENTATION SHOWING WAIVER. NEW INSTALLATION TO BECOMPLETED PRIOR TO RECEIVING CREDIT FOR NEXT COI.
Construction/Loadline
Issued 6 March 1991
Resolved
HAVE COAST GUARD INSPECTOR CHECK MODIFICATIONS ON BALLAST SYSTEM AS PER APPROVED PLANS.
Electrical
Issued 25 February 1991
Resolved
REPAIR/REPLACE ALL MISSING / BROKEN LIGHT INDICATORS ON MAIN ALARM PANEL._x001C_TO BE COMPLETE PRIOR TO SAILING.
Electrical
Issued 25 February 1991
Resolved
PROVE OVERSPEED LOW LUBE OIL PRESSURE, AND HI JACKET WATER TEMP ALARMS ON BOTH S/S DIESEL GENERATORS. TO BE COMPLETE PRIOR TO SAILING.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
INSTALL RUBBER MATTING AROUND EMERGENCY SWITCHBOARD. TO BE COMPLETE PRIORMOREAILING.
Electrical
Issued 25 February 1991
Resolved
BLOCK AND REPLACE ALL EMERGENCY BATTERIES PROPERLY, TO BE COMPLETE PRIOR TO SAILING
Fire Fighting
Issued 25 February 1991
Resolved
REPLACE ONE 1.5 INCH FIRE HOSE.
Construction/Loadline
Issued 25 February 1991
Resolved
PROVE GENERAL SERVICE PUMP IS CAPABLE OF PUMPING AT LEAST 100 PSI._x001C_ TO BE COMPLETE PRIOR TO SAILING.
Engineering
Issued 25 February 1991
Resolved
REMOVE REACH RODS FOR DEEP TANK VALVES (DISCONNECTED AND NO LONGER USED)
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
CLEAN OIL FROM DECK IN AFT STEERING ROOM. TO BE COMPLETE PRIOR TO SAILING.
Lifesaving
Issued 25 February 1991
Resolved
REPAIR AND SERVICE WATERTIGHT SCUTTLE ABOVE AFTER STEERING. TO BE COMPLETEPRIOR TO SAILING.
Electrical
Issued 25 February 1991
Resolved
REMOVE TEMP. LIGHTING, BLOCKING AFT ESCAPE IN SHAFT ALLEY. TO BE COMPLETE PRIOR TO SAILING.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REMOVE DEBRIS BLOCKING ACCESS TO CO2 ROOM AND FIRE STATION #10. TO BE COMPLETE PRIOR TO SAILING.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPAIR HANDRAIL AFT PORT SIDE BY REPLACING MISSING BAR.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
LOOSEN ALL DOGS ON COVER OF EMERGENCY GENERATOR INTAKE.
Navigation
Issued 25 February 1991
Resolved
REPLACE STERN LIGHT AS SOON AS REPLACEMENT ARRIVES.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPAIR ESCAPE TRUNK HATCH AND LADDER FROM ENGINEROOM TO MAIN DECK. TO BE COMPLETE PRIOR TO SAILING.
Fire Fighting
Issued 25 February 1991
Resolved
HAVE ALL FIRE EXTINGUISHERS SERVICED AS WELL AS ALL FIXED SYSTEMS. TO BE COMPLETE PRIOR TO SAILING
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPLACE FLAME SCREENS ON ALL VENTS TO F.O. TANKS ONMAIN DECK, PRIOR TO SAILING.
Lifesaving
Issued 25 February 1991
Resolved
CLEAN OUT COOLING WATER INTAKE ON MOTOR LIFEBOAT.
Lifesaving
Issued 25 February 1991
Resolved
HAVE LIFEBOAT RADIO REPAIRED AND PROVE OPERATION PRIOR TO SAILING.
Fire Fighting
Issued 25 February 1991
Resolved
REPAIR BROKEN FIRE DAMPER STARBOARD SIDE #2 TABERNACLE.
Navigation
Issued 25 February 1991
Resolved
HAVE RADAR REPAIRED AND PROVE OPERATION PRIOR TO SAILING.
Electrical
Issued 25 February 1991
Resolved
HAVE VESSELS MAIN RADIO TRANSMITTER REPAIRED AND PROVE OPERATION PRIOR TO SAILING.
Fire Fighting
Issued 25 February 1991
Resolved
REPAIR LEAKING STOP VALVE ON PORT ENGINE ROOM FIRE STATION.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
OBTAIN CORRECT TYPE OF MSD CHLORINE.
Fire Fighting
Issued 25 February 1991
Resolved
PAINT EMERGENCY FIREPUMP REMOTE VALVE HANDLES RED AND LABEL REMOTE CONTROLLER.
Electrical
Issued 25 February 1991
Resolved
REMOVE PORTABLE LIGHTING JURY RIGS THROUGHOUT ENGINEERING SPACES.
Electrical
Issued 25 February 1991
Resolved
REPAIR/REPLACE ALL MISSING LIGHTING GLOBES AND GUARDS AND INOPERATIVE LIGHTING IN ALL ENGINEERING SPACES._x001C_
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REMOVE/CLEAN UP ALL LOOSE, EXCESS GEAR IN COMPT UNDER FORECASTLE.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPLACE GASKET ON MANHOLE TO #1 CARGO HOLD.
Construction/Loadline
Issued 25 February 1991
Resolved
REPLACE DECK DRAINS ON THE HOUSE.
Engineering
Issued 25 February 1991
Resolved
PROVE PROPER OPERATION OF REMOTE REACH ROD VALVES F.O. SERVICE AND F.O. SETTLING ABOVE SHAFT ALLEY WTD.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPLACE MISSING STANCHION PORT SIDE GANGWAY.
Lifesaving
Issued 25 February 1991
Resolved
REPAIR/REPLACE GENERAL ALARM BELLS, MAIN DECK PORT SIDE HOUSE, MAIN DECK STBD SIDE HOUSE INTERIOR, INTERIOR 01 DECK FWD BULKHEAD.
Lifesaving
Issued 25 February 1991
Resolved
REPAIR FUEL OIL PET COCK IN MOTOR LIFEBOAT.
Lifesaving
Issued 25 February 1991
Resolved
REPLACE RUBBER BALLS IN BOTH LIFEBOATS.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPLACE MISSING STUDS AND NUTS ON MANHOLE COVER TO CHAIN LOCKER.
Fire Fighting
Issued 25 February 1991
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIREPUMP ON EMERGENCY POWER. TO BE COMPLETE PRIOR TO SAILING_x001C_
Navigation
Issued 25 February 1991
Resolved
REPAIR AND PROVE OPERATION OF STEERING GEAR CONTROLS ON THE BRIDGE.
Electrical
Issued 25 February 1991
Resolved
REMOVE OR PROPERLY SECURE ARMOR CABLE IN GALLEY IN SERVING AREA.
Construction/Loadline
Issued 25 February 1991
Resolved
REPAIR CRACK IN #3 CARGO HATCH COMBING SUPPORT.
Electrical
Issued 25 February 1991
Resolved
REPLACE MISSING GLOBES AND GUARDS ON LIGHT FIXTURES IN FORECASTLE.
Accommodation/Occupational Safety
Issued 25 February 1991
Resolved
REPLACE SAFETY CHAINS ON FORECASTLE.
Construction/Loadline
Issued 25 February 1991
Resolved
FUEL OIL CONTAIN MENT ON BOTH SIDES NEED PLUGS.
Fire Fighting
Issued 25 February 1991
Resolved
ALL PORTABLE, SEMI PORTABLE, AND FIXED FIRE FIGHTING EQUIPMENT NEEDS TO BESERVICED PRIOR TO SAILING. A COPY OF REPORT IS TO BE PROVIDED.
Navigation
Issued 31 October 1990
Resolved
PROVIDE DETAILED PLANS TO THE MSC, SHOWING ALL MODS. TO THE VSL'S STEERING SYSTEM. THE PLANS SHOULD COVER THE ENTIRE SYS. (HYD. SYS, ALARM SYS, MECH. LINKAGES, ELEC. CONTROLS, ETC.) AND CLEARLY DELINEATE WHAT PARTS ARE ORIG. AND PARTS THAT ARE MOD. OR ADDED.
Navigation
Issued 22 February 1990
Resolved
REPLACE CURRENT STEERING GEAR SYSTEM WITH A SYSTEM MEETING ALL CURRENT COAST GUARD AND SOLAS REQUIREMENTS.
Navigation
Issued 22 February 1990
Resolved
SUBMIT PLANS FOR APPROVAL TO THE CG MARINE SAFETY CENTER WASHINGTON, DC FORTHE NEW STEERING GEAR SYSTEM.
Construction/Loadline
Issued 22 February 1990
Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR A PERMANENT SEGREGATED BALLAST SYSTEM.
Fire Fighting
Issued 22 February 1990
Resolved
SUBMIT PLANS FOR APPROVAL TO THE COAST GUARD MARINE SAFETY CENTER, WA. DC FOR ALL MAJOR MODIFICATIONS TO THE VSL INCLUDING BUT NOT LIMITED TO: A)FIRECONTROL PLAN. B) NEW HALON INSTALLATION IN THE PAINT LOCKER. C)MODIFICATIONTO THE AFTER MAIN DECK LEVEL INCLD STRUCTURAL FIRE PROTECTION DETAILS.
Engineering
Issued 22 February 1990
Resolved
PROVIDE AND MOUNT SCHEMATICS FOR ALL MOTOR CONTROLLERS.
Navigation
Issued 22 February 1990
Resolved
INSTALL GUARDS OVER STEERING PUMP COUPLINGS.
Accommodation/Occupational Safety
Issued 22 February 1990
Resolved
INSTALL TABLE IN HOSPITAL.
Navigation
Issued 22 February 1990
Resolved
ENLARGE AND POST PRESENT STEERING GEAR OPERATING INSTRUCTIONS.
Electrical
Issued 1 February 1990
Resolved
MAKE PERMANENT REPAIRS TO THE LEAK IN THE SEA WATER COOLING LINE ON NUMBER 2 GENERATOR IN WAY OF THE SOFT PATCH.
Lifesaving
Issued 31 October 1989
Resolved
HAVE NEW LIFEBOAT PLATES AND RECERTIFICATION PLATES INDICATING DERATING FOR30 PERSONS, FABRICATED FOR BOTH LIFEBOATS.
Accommodation/Occupational Safety
Issued 31 October 1989
Resolved
REPAIR SINK IN STEWARD'S UTILITY ROOM (1-131-2) SO PERMANENT HOT AND COLD RUNNING WATER IS SUPPLIED.
Accommodation/Occupational Safety
Issued 31 October 1989
Resolved
MAKE NEW HOSPITAL INSTALLATION COMPLY WITH 46CFR92.20-35(C) IN REGARDS TO BERTHS AND 46CFR92.20-35(E) IN REGARDS TO OTHER NECESSARY SUITABLE EQUIPMENT.
Construction/Loadline
Issued 31 October 1989
Resolved
REPAIR/REPLACE VENT COVER ON FORWARD BULKHEAD OF HOUSE, MAIN DECK PORT SIDEOUTBOARD OF LADDER.
Navigation
Issued 31 October 1989
Resolved
REPAIR/REPLACE SOUND POWERED TELEPHONE CASING ON FORECASTLE IN ORDER TO PROVIDE WATER-TIGHT CASING FOR TELEPHONE.
Electrical
Issued 31 October 1989
Resolved
REPAIR/REPLACE LIGHT COVERS AND CAGES THROUGHOUT HOUSE AND INCLUDING CREW ACCOMMODATION SPACES.
Construction/Loadline
Issued 31 October 1989
Resolved
CROP OUT TO GOOD METAL AND RENEW LOWER SECTION OF PORT HOLE FRAMING IN THE 2ND ENGINEER'S STATEROOM.
Navigation
Issued 31 October 1989
Resolved
PROVE NAVIGATION LIGHTS ARE IN ACCORDANCE WITH THE CURRENT COLREGS.
Construction/Loadline
Issued 31 October 1989
Resolved
HOSE TEST HATCH ON AFTER POOP-DECK JUST FWD OF NUMBER 4 HOLD.
Construction/Loadline
Issued 31 October 1989
Resolved
PROPERLY SEAL ALL BULKHEAD PENETRATIONS WITH COAST GUARD APPROVED FIRE STOPMATERIAL.
Construction/Loadline
Issued 31 October 1989
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARILY PATCHED HOLE BETWEEN NO. 4 HATCH AND THE AFTER STAIRCASE.
Construction/Loadline
Issued 31 October 1989
Resolved
PROPERLY REPAIR WASTED COAMING OUTBOARD OFTHE AFTER STBD. CHOCK.
Navigation
Issued 31 October 1989
Resolved
PROPERLY LABEL CALL NUMBERS FOR SOUND POWERED TELEPHONE SYSTEM.
Documentation
Issued 31 October 1989
Resolved
PROVIDE AND POST MANUEVERING INFORMATION FACT SHEET ON THE BRIDGE.
Electrical
Issued 31 October 1989
Resolved
REMOVE BOX OR PROPERLY JOIN WIRES TO BOX IN PASSAGEWAY, 01 DECK NEXT TO THESTAIRCASING.
Lifesaving
Issued 31 October 1989
Resolved
PROVIDE INSTRUCTIONS FOR ON-BOARD MAINTENANCE OF LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS CHAPTER III, REGULATION 52.
Accommodation/Occupational Safety
Issued 31 October 1989
Resolved
E1 INSTALL A MARINE SANITATION DEVICE(S) WITH A TOTAL CAPACITY FOR 30 PERS.THE HOSPITAL MUST BE PLUMBED INTO THE SYSTEM. THE HOSPITAL TOILET MAY NOT BE USED IN INLAND WATERS UNTIL PIPING COMPLETE. 2 MSD'S NOW INSTALLED ONLY GOOD FOR 16 PERSONS, #4 STBD DB IS TEMP MSD TANK.
Construction/Loadline
Issued 31 October 1989
Resolved
E2 INSTALL A BALLAST MONITOR OR PROVIDE A PERMENENT SEGREGATED BALLAST SYSTEM.
Navigation
Issued 31 October 1989
Resolved
E3 CLEAN OR REPLACE THE HYDRAULIC OILSTORAGE TANK FOR STEERING GEAR. IF TANK IS CLEANED, HAVE TANK INSPECTED BY A CG MARINE INSPECTOR PRIOR TO FILLING WI6TH OIL. RECONNECT TANK AFTER INSTALLATION.
Engineering
Issued 31 October 1989
Resolved
E4 REPAIR'REPLACE COOLING WATER PRESSURE GAUGE ON #1 MAIN GENERATOR.
Engineering
Issued 31 October 1989
Resolved
E5 REPAIR AND PROVE OPERATION OF THE EDUCTOR ON THE PORT SIDE IN THE FORWARD BOSN STORE ROOM.
Navigation
Issued 31 October 1989
Resolved
E6 PROVIDE STEERING FAILURE ALARM SYSTEM PER 46CFR 113.43
Navigation
Issued 31 October 1989
Resolved
E7 PROVIDE VISUAL INDICATION ON THE BRIDGE SHOWING WHICH STEERING MOTOR IS IN OPERATION.
Lifesaving
Issued 31 October 1989
Resolved
ADD LIFEBOAT MOTOR OPERATING INSTRUCTIONS TO SOLAS TRAINING MANUAL AND DISTRIBUTE MANUAL IAW SOLAS CHAPTER III, REGULATION 18.
Lifesaving
Issued 31 October 1989
Resolved
HAVE LIFEBOAT DAVIT MANUAL BRAKE SERVICED BY A MANUFACTURERS REPRESENTATIVEOR EQUIVALENT SO BRAKE DOES NOT SLIP OR BOUNCE EXCESSIVELY IN BOTH THE DRY AND WET CONDITIONS. AFTER SERVICE,TEST IAW 46 CFR 94.35-5 IN THE PRESENCE OF A COAST GUARD INSPECTOR. (PORT DAVIT)
Fire Fighting
Issued 31 October 1989
Resolved
PROPERLY REPAIR 6 LEAKING COUPLINGS ON FIREMAIN, MAINDECK. NOTE: COUPLING BOLTS WERE REPLACED BUT THEN COUPLINGS COULD NOT BE SEALED PROPERLY. HYDRO FIREMAIN TO 150 PSIG.
Unknown
Issued 31 October 1989
Resolved
SUBMIT PLANS FOR APPROVAL TO THE COAST GUARD MARINE SAFETY CENTER, WA. DC FOR ALL MAJOR MODIFICATIONS TO THE VESSEL INCLUDING BUT NOT LIMITED TO: A) FIRE CONTROL PLAN. B) NEW HALON INSTALLATION IN THE PAINT LOCKER. C) MODIFICATIONS TO THE AFTER MAIN DECK LEVEL INCLD STRUCTURAL FIRE PRO DETS.
Fire Fighting
Issued 31 October 1989
Resolved
REPAIR/REPLACE LEAKING PACKING ON VALVE FOR FIRE STATION NO. 3.
Fire Fighting
Issued 31 October 1989
Resolved
REPAIR/REPLACE LEAKING VALVES AT FIRE STATIONS NO. 6 AND NO. 7.
Fire Fighting
Issued 31 October 1989
Resolved
STENCIL FIRE STATIONS IN ACCORDANCE WITH THE FIRE CONTROL PLAN.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.