MAURY USCG vessel records Sign in
← All vessels

SUBSEA RESPONDER II

SUBSEA RESPONDER II is a 2000 offshore supply vessel. The Coast Guard has recorded 37 inspections since 2000, most recently in July 2026, along with 67 deficiencies and 2 operational controls.

Records from 2000 to 2026. Most recent: inspection, 10 July 2026.

Built
2000
Last inspected
10 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9225495 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
338685000, 367546000, 368151000 (licence lapsed)
Maury page id
psix-203

Inspections, by type

…with no type recorded6
Years with a record 18 calendar years (2000–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it668 - Convention (Subpart B), Net Ton
2227 - Convention (Subpart B), Gross Ton
2404 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF5354MMSI 368151000 · cancelled · compulsorily equipped · granted 29 July 2010, cancelled 29 January 2015 · licensed under a name not among this hull’s recorded names (not shown)
WXCDMMSI 367546000 · expired · compulsorily equipped · granted 10 August 2006, cancelled 15 October 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCZ6370MMSI 338685000 · cancelled · compulsorily equipped · granted 24 January 2000, cancelled 19 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUCCESS Offshore Supply Vessel · MISLE 48950 · 4 June 2000 · activity 12796

Inspection history · 37

10 July 2026 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8431838
10 December 2024 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8045841
4 September 2024 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7995319
17 April 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7909307
27 April 2023 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7629856
5 August 2021 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7272656
15 December 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7112387
15 December 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7117543
18 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7097577
22 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6957778
5 March 2020 PSC A
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6928609
27 May 2014 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4870553
15 December 2011 COI Inspection · MARPOL Annex IV Survey · MTSA/ISPS Verification · MARPOL Annex VI Survey · Plan Review (Other than "T") · DAPI Audit · Internal Structural Exam · Construction Oversight · Drydock Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4209031
4 October 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3862852
4 October 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3862885
30 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3550778
27 April 2009 MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3456669
11 November 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3363103
25 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3456819
7 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3260549
25 February 2008 Annual Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3158097
24 January 2007 COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2860936
24 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2689435
9 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2582285
4 February 2005 Examination of Repairs · MTSA/ISPS Verification · Internal Structural Exam · Cargo Tank Internal · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2289287
14 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2274921
12 November 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2239828
21 October 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2239812
30 June 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2116626
5 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2060809
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997346
22 January 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1990436
13 January 2003 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1739122
25 January 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1481270
20 February 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399548
4 June 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 12796
1 February 2000 Initial Certification · Hull Examination · Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1423314

Deficiency record · 67

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 September 2024 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. Vessel's Chief Engineer stated there was a jacket water leak on the number 2 cylinder, a possible crack in the cylinder liner. Did not want to start the engine to avoid a possible engine failure. SOLAS 74 (2001) II-1 / 43 / 2
Action required: 30 - Ship detained
Resolved 18 October 2024
Resolution: Reviewed class report and verified operation of emergency generator.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 4 September 2024 Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations. The vessel’s crew was unable to provide SMS procedures upon request and were unfamiliar with the vessel’s Safety Management System. Based on this and the technical and operational nature of the deficiencies noted below provide objective evidence of a serious failure of implementation of the ISM code. An additional external verification is required to be carried out by the RO (ABS) prior to the vessel’s departure from port. 74 SOLAS (20) Ch. IX Reg 3.1 ISM Code Part A 10.1 – Cite Code 30
Action required: 30 - Ship detained
Resolved 18 October 2024
Resolution: Reviewed class report, verified ISM audit conducted and implementation of applicable ISM procedures.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 4 September 2024 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page or group of electronic entries shall be signed by the master of ship. The master of the vessel had not signed required pages and C/E had failed to log the OWS testing. Testing was recorded in a separate binder. MARPOL I/17.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: Verified all Masters signature on completed pages of ORB and test conducted of OWS to include log entry in ORB
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 4 September 2024 Resolved
A line-throwing appliance complying with the requirements of section 7.1 of the Code shall be provided. 04 line-throwing appliances were expired. Vessel showed me a requisition dated 22Jul2024 for new line-throwing appliances, as of inspection dated company had not purchased. SOLAS (2020) III/18
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: Vessel replace line throwing devices; experation date of July 2027.
11 - Life Saving Appliances › N/A - No Subsystem › Emergency equipment for 2-way comm.
Issued 4 September 2024 Resolved
At least 3 two-way VHF radiotelephone apparatus shall be provided on every passenger ship and on every cargo ship of 500 gross tonnage and upwards. 03 batteries for the VHF radiotelephone were expired,(June2024), requistion was submitted 22Jul2024 to replace expired batteries, as of date of inspection company had not purchased. SOLAS 74 (2020) III / 6.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: Vessel replaced expired batteries; experation date August 2029.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 September 2024 Resolved
In cargo ships of 2,000 gross tonnage and upwards, if a fire in any one compartment could put all the pumps out of action there shall be an alternative means consisting of a fixed independently driven emergency pump which shall be capable of supplying two jets of water to the satisfaction of the Administration. Emergency fire pump was not able to supply the stbd side bridge wing and port side main deck to adequate water. 74 SOLAS (2001) II-2 / 4 / 3.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: Vessel removed opstuction from branch piping. Verified satisfactory operation of emergency fire pump and witnessed adequate pressure to two fire plugs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2024 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Dead end and exposed wires were found in several areas of the engine room. 1. Dead end wire in Ships Alarm Panel 2.Exposed wires in Sound Power Phone Junction Box 3. Emergency lighting at stbd hatch to Z-drive room 4. Shore tie cable stbd side termination into panel 5. Exposed wires next to 20 AMP battery charger in emergency generator space. 74 SOLAS (2001) II-1/45/1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: Verified proper termination of electrical wiring.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 September 2024 Resolved
Where "A" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc., or for girders, beams or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired, subject to the provisions of regulation 30.5. Vessel had a hole cut into the stbd side bulkhead from the escape truck to run the shore tie cable into the space. Spray foam was used to seal the area around the cable. The upper cable penetration was missing a portion of the "rocks block" allowing daylight from the open escape hatch to enter the space. 74 SOLAS (2001) II-2/18/1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: Verified proper installation of cable penetrations through fire boundaries.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 27 April 2009 Resolved
Tie in portable quarters fire alarm to general alarm bell; two minute as per SOLAS requirements; prior to sailing international.
Action required: 705 - Other - as specified
Resolved 27 July 2009
Resolution: Witness by [name withheld] with ABS. Rcvd call stating it was fixed.
Documentation › Markings/Placards › Warning Signs
Issued 27 April 2009 Resolved
Replace SOLAS decals on bridge wings; distress signals, life rafts, line throwing gun...
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 28 July 2009
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 27 April 2009 Resolved
Label deep fat fryer and stove emergency disconnects.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 28 July 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 April 2009 Resolved
Stencil bow thruster vents with proper marking for closure in case of fire.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 28 July 2009
Personnel › Certificates/Documents/Licenses › MMD, GMDSS At-sea Maintainer
Issued 4 April 2008 Resolved
Provide GMDSS Maintenance endorsement or GMDSS maintenance agreement contract with servicing company.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 7 July 2008
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 4 April 2008 Resolved
Provide vessel response plan prior to carring oil base muds or prior to resolution date whichever is first.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 7 July 2008
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 4 April 2008 Resolved
Provide approved ABS electrical load analysis.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 7 July 2008
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 4 April 2008 Resolved
Prove proper operation of all generator overspeeds prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2008
Resolution: Accepted third party technician report.
Stability › Watertight Integrity › General
Issued 4 April 2008 Resolved
Repair marine cable transits in Z drive rooms to engine room prior to getting underway. Transits are miss matched with two different vendors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2008
Resolution: Accepted third party technician report.
Stability › Watertight Integrity › General
Issued 4 April 2008 Resolved
Replace gasket on water tight door to thruster room.
Action required: 705 - Other - as specified
Resolved 6 April 2008
Resolution: Accepted photo of replaced gasket.
Engineering › Fuel Oil Service System › Hose
Issued 25 February 2008 Resolved
Repair fuel oil leak on center generator engine prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2008
Resolution: Accepted third party technician report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 25 February 2008 Resolved
Provide proposal for repair or equivalent safety to water tight door opening into CO2 protected bow thruster room.
Due 19 April 2008
Resolved 7 July 2008
Stability › Watertight Integrity › General
Issued 24 January 2007 Resolved
Demonstrate Proper Operation of WTD leading to Bow Thruster room. Door does not close.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 24 January 2007 Resolved
Provide Auto door closure for all WTDs that surround CO2 protected space.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 January 2007 Resolved
Complete annual service for fixed CO2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Communications › Radio Communications › Emergency Source of Power
Issued 24 January 2007 Resolved
Demonstrate proper operation of SSB on emergency power
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2007
Communications › Radio Communications › Emergency Source of Power
Issued 24 January 2007 Resolved
Provide emergency power for extra VHF radio.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 January 2007 Resolved
Provide Visual and Audible alarm for engine room bilge alarm at operating station.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Communications › Alarms/Indicators › General Alarm
Issued 24 January 2007 Resolved
Post General Alarm placards at all GE bells, including the ROV spaces.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Documentation › Certificates/Documents › FCC SSL
Issued 24 January 2007 Resolved
Update call sign onboard in accordance with SSL. Emergency Boradcast Placard, EPIRB registration, AIS etc.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 24 January 2007 Resolved
Provide first aid kit that does not have expired medicine.
Due 26 February 2007
Resolved 26 January 2007
Documentation › Logs/Records › Logbook (official)
Issued 24 January 2007 Resolved
Log Rescue Boat operation.
Action required: 705 - Other - as specified
Resolved 30 July 2007
Resolution: COMPLETED
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 24 January 2007 Resolved
Provide rubber mat in front of emergency switchboard.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 24 January 2007 Resolved
Fix small f/o leak in bow thruster f/o filter and sight glass.
Due 26 February 2007
Resolved 1 August 2007
Resolution: COMPLETED
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 24 January 2007 Resolved
Label emergency steering station P/S.
Due 25 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 24 January 2007 Resolved
Demonstrate Proper Operation of all three generator overspeed trips.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2007
Engineering › Bilge Water Management System › Manifold
Issued 24 January 2007 Resolved
Label bilge manifold.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Electrical › Electric Generation Source (service) › Generator
Issued 24 January 2007 Resolved
Permanently wire magnetic pick-up on stbd generator - no wire nuts.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 January 2007 Resolved
Provide Fire and Safety Plan for Approval
Action required: 705 - Other - as specified
Resolved 1 August 2007
Resolution: COMPLETED
Operations/Management › Pollution › Control of Garbage
Issued 24 January 2007 Resolved
Provide/Post Waste Management Plan
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Fire Fighting › Fire Pumps › Pressure
Issued 24 January 2007 Resolved
Install fire pump gauge at operating station.
Due 26 February 2007
Resolved 30 July 2007
Resolution: COMPLETED
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 31 December 2006
Resolved 24 January 2007
Communications › Radio Communications › Emergency Source of Power
Issued 24 April 2006 Resolved
Provide spare sealed lifeboat safety radio batteries for all three life boat radios.
Due 31 May 2006
Resolved 24 January 2007
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 24 April 2006 Resolved
Repair A60 insulation in emergency generator space.
Due 24 May 2006
Resolved 24 January 2007
Engineering › Compressed Air System (start air) › Valve
Issued 24 April 2006 Resolved
Provide thrid party test certificates for all air receiver relief valves.
Due 24 May 2006
Resolved 24 January 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 April 2006 Resolved
Provide third party certificate verifying calibration and proper operation of OWS. Oily water seperator not to be used until OWS re-certified/calibrated.
Due 24 May 2006
Resolved 30 July 2007
Resolution: COMPLETED
Engineering › Fuel Oil Service System › Filter
Issued 22 January 2004 Resolved
Provide metallic plugs for #2 Generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2004
Resolved 22 January 2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 22 January 2004 Resolved
Renew fuel oil hose on #1 main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2004
Resolved 22 January 2004
Stability › Watertight Integrity
Issued 22 January 2004 Resolved
Repair and adjust bow thruster hatch. LEGACY COMPONENT DESC: Bow Thruster Watertight hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2004
Resolved 22 January 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 22 January 2004 Resolved
Renew flame screen on port fuel tank vent.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2004
Resolved 22 January 2004
Engineering
Issued 13 January 2003 Resolved
Complete Automation testing as per approved procedures dated 20SEP01. Foward report to [name withheld].
Due 30 January 2003
Resolved 14 January 2003
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 13 January 2003 Resolved
Provide Cargo Ship Safety Radio Certificate onboard vessel.
Due 13 January 2003
Resolved 13 January 2003
Engineering › Fuel Oil Service System › Valve
Issued 13 January 2003 Resolved
Prior to sailing, repair and prove proper operation of emergency fuel cut out valve for emergency generator.
Due 17 January 2003
Resolved 15 January 2003
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 13 January 2003 Resolved
Prior to sailing, provide projectiles for line throwing appliances.
Due 17 January 2003
Resolved 13 January 2003
Documentation › Logs/Records
Issued 13 January 2003 Resolved
Provide fire fighting equipment and safety equipment servicing reports to [name withheld].
Due 17 January 2003
Resolved 13 January 2003
Engineering
Issued 13 January 2003 Resolved
Prior to sailing, repair and prove proper operation of bow thruster room bilge alarm.
Due 17 January 2003
Resolved 14 January 2003
Construction/Loadline › Structures › Ventilators
Issued 13 January 2003 Resolved
Repair gaskets and adjust ventilation closures for bow thruster compartment vents on forcastle.
Due 30 January 2003
Resolved 17 January 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 January 2003 Resolved
Prior to fuel transfer operations, complete hydrostatic testing of transfer hose.
Due 30 January 2003
Resolved 15 January 2003
Engineering
Issued 13 January 2003 Resolved
Remove fuel from filter bowls and bilge area in way of ships service generators.
Due 17 January 2003
Resolved 15 January 2003
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 13 January 2003 Resolved
Prior to sailing, provide suitable wrenches and prove proper operation of all fuel oil cutout valves/reachrods on cargo deck.
Due 17 January 2003
Resolved 15 January 2003
Electrical › Electric Supply System (service)
Issued 13 January 2003 Resolved
Provide approved drawings/ manufactures wiring specifications to resolve tripping of bow thruster hydraulic pumps when ventilation shutdown is activated.
Due 30 January 2003
Resolved 15 January 2003
Resolution: Approved drawing concur with actual wiring, Otto Candies investigating reason for wiring scheme.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 25 January 2002 Resolved
PORT EMERGENCY STEERING ENGINE ORDER TELEGRAPH ELECTRONIC POSITIONING INDICATOR AT PILOT HOUSE NOT CORRESPONDING TO ENGINE ROOM FUNCTIONS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2002
Resolved 26 January 2002
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 25 January 2002 Resolved
CONDEMENED JACKETWATER HOSE STBD MAIN ENGINE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 25 January 2002
Documentation
Issued 1 February 2000 Resolved
VESSEL IS RESTRICTED FROM OPERATING UNDER THE AUTHORITY OF ITS CERTIFICATE OF INSPECTION UNTIL THE SOPEP HAS BEEN APPROVED AND PROOF OF APPROVAL HAS BEEN PROVIDED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Deck/Cargo
Issued 1 February 2000 Resolved
OIL DISCHARGE REMOVAL EQUIPMENT MUST BE ONBOARD IAW 33CFR155.220.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Electrical
Issued 1 February 2000 Resolved
AUTOMATION TEST PROCEDURES MUST BE SUBMITTED AND APPROVED BY MARINE SAFETY CENTER.
Condition: Unknown
Due 1 March 2000
Resolved 13 January 2003
Navigation
Issued 1 February 2000 Resolved
PROVIDE GMDSS CERTIFICATION TO MSO MOBILE.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Documentation
Issued 1 February 2000 Resolved
FUEL OIL TRANSFER PROCEDURES MUST BE SUBMITTED TO MSO MOBILE FOR REVIEW IAW33CFR 155.720.
Condition: Unknown
Due 1 March 2000
Resolved 22 January 2004
Navigation
Issued 1 February 2000 Resolved
PROVIDE COPY OF PERMANENT RADIO STATION LICENSE TO MSO MOBILE.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000