Documentation record
Registered dimensions (L × B × D)51.8 ft × 17.0 ft × 6.1 ft
Registered tonnagegross 45 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUDSON SHIPBUILDERS INC · PASCAGOULA MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un, rec, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
26 August 2014
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4967794
28 October 2013
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4745454
12 September 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4716045
22 August 2012
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4420136
19 August 2010
MARPOL · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3906880
23 March 2009
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3438653
17 December 2008
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3381741
29 October 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3353818
3 September 2008
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3317142
18 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3166867
10 January 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2853535
9 January 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2853169
25 July 2006
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2747248
18 April 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2627490
2 February 2006
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2578284
27 June 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2432301
29 January 2005
Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2286568
11 September 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 81789
25 May 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 818656
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 September 2008
Resolved
Covers and labeling needed on Circuit Breaker Panel Boxes in machinery space, wheel house and galley. "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Covers and labeling now installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 September 2008
Resolved
Non conductive mat needed by electric switch panel. "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Non conductive mat now installed.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 3 September 2008
Resolved
Searchlight not operating properly (not moving up & down) as required under 33 CFR 164.72.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Searchlight now operating properly.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 3 September 2008
Resolved
Provide proof fire detection system is working properly on battery back-up power as required under 46 CFR 27.203.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Fire Detection now working properly on battery back up power.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 3 September 2008
Resolved
Provide proof fire detection system is certified by a professional engineer or classification society as required under 46 CFR 27.203
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Fire detection system now certified.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 July 2006
Resolved
Ensure diamond plating in Eng Room is cleaned.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: oil cleaned fm deck.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 25 July 2006
Resolved
Gen Housekeeping for Eng Room and Accommodation Spaces.
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 26 July 2006
Resolution: Areas Cleaned
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 25 July 2006
Resolved
Blank off or repair heater in Berthing Area
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Blanked off
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 July 2006
Resolved
Ensure all outlet & switch box covers are installed.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: installed
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 July 2006
Resolved
Ensure covers are on the circuit breaker boxes.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Outer covers are not on but all blanks are covered, see narrative.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006
Resolved
Ensure all wiring in Eng Rm is secured w/ metal clamps.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2006
Resolved
Ensure stbd running light operational.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: changed light
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2006
Resolved
Fix aft amber upper light
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: new light installed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 July 2006
Resolved
Ensure proper operation of radar.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Placed on a own circuit.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 July 2006
Resolved
Replace 04 condemned lifejackets.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: replaced
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 25 July 2006
Resolved
Tighten shaft packings.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: No drip on both port and stbd.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2006
Resolved
Replace bilge pump on stbd packing well.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Found to be operational.
Engineering › Fuel Oil Service System › Filter
Issued 25 July 2006
Resolved
Eng Leaking oil find and repair leak.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: filter leaking on stbd eng.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2006
Resolved
Clean excess oil in bilges.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Pumped out
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 February 2006
Resolved
Need to install a lighted magnetic compass.
Condition: Improper Installation
Due 13 April 2006
Resolved 7 April 2006
Fire Fighting › Fixed Fire Detection System › Approval
Issued 2 February 2006
Resolved
Need to provide proof that fixed fire detection system is certified by a professional engineer or classification society.
Condition: Unknown
Due 13 April 2006
Resolved 7 April 2006