MAURY USCG vessel records
← All vessels

BONNIE G SELVICK

Built
1981
Last inspected
26 August 2014
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 August 2014
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2000–2014)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE5682
203494
Flag
UNITED STATES
Maury page id
psix-203494

Documentation record

Registered dimensions (L × B × D)51.8 ft × 17.0 ft × 6.1 ft
Registered tonnagegross 45 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUDSON SHIPBUILDERS INC · PASCAGOULA MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un, rec, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ABC 301 Freight Barge · MISLE 159993 · 27 June 2005 · activity 2432301SCNO 8116 Freight Barge · MISLE 195408 · 27 June 2005 · activity 2432301RCI 253B Freight Barge · MISLE 379768 · 27 June 2005 · activity 2432301RCI 255B Freight Barge · MISLE 379774 · 27 June 2005 · activity 2432301IMT 103 Freight Barge · MISLE 4159 · 11 September 2000 · activity 81789

Inspection history · 19

26 August 2014 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4967794
28 October 2013 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4745454
12 September 2013 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4716045
22 August 2012 DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4420136
19 August 2010 MARPOL · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3906880
23 March 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3438653
17 December 2008 Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3381741
29 October 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3353818
3 September 2008 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3317142
18 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3166867
10 January 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2853535
9 January 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2853169
25 July 2006 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2747248
18 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2627490
2 February 2006 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2578284
27 June 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2432301
29 January 2005 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2286568
11 September 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 81789
25 May 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 818656

Deficiency record · 21

Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 September 2008 Resolved
Covers and labeling needed on Circuit Breaker Panel Boxes in machinery space, wheel house and galley. "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Covers and labeling now installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 September 2008 Resolved
Non conductive mat needed by electric switch panel. "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Non conductive mat now installed.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 3 September 2008 Resolved
Searchlight not operating properly (not moving up & down) as required under 33 CFR 164.72.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Searchlight now operating properly.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 3 September 2008 Resolved
Provide proof fire detection system is working properly on battery back-up power as required under 46 CFR 27.203.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Fire Detection now working properly on battery back up power.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 3 September 2008 Resolved
Provide proof fire detection system is certified by a professional engineer or classification society as required under 46 CFR 27.203
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 29 October 2008
Resolution: Fire detection system now certified.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 July 2006 Resolved
Ensure diamond plating in Eng Room is cleaned.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: oil cleaned fm deck.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 25 July 2006 Resolved
Gen Housekeeping for Eng Room and Accommodation Spaces.
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 26 July 2006
Resolution: Areas Cleaned
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 25 July 2006 Resolved
Blank off or repair heater in Berthing Area
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Blanked off
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 July 2006 Resolved
Ensure all outlet & switch box covers are installed.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: installed
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 July 2006 Resolved
Ensure covers are on the circuit breaker boxes.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Outer covers are not on but all blanks are covered, see narrative.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006 Resolved
Ensure all wiring in Eng Rm is secured w/ metal clamps.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2006 Resolved
Ensure stbd running light operational.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: changed light
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2006 Resolved
Fix aft amber upper light
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: new light installed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 July 2006 Resolved
Ensure proper operation of radar.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Placed on a own circuit.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 July 2006 Resolved
Replace 04 condemned lifejackets.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: replaced
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 25 July 2006 Resolved
Tighten shaft packings.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: No drip on both port and stbd.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2006 Resolved
Replace bilge pump on stbd packing well.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Found to be operational.
Engineering › Fuel Oil Service System › Filter
Issued 25 July 2006 Resolved
Eng Leaking oil find and repair leak.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: filter leaking on stbd eng.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2006 Resolved
Clean excess oil in bilges.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Pumped out
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 February 2006 Resolved
Need to install a lighted magnetic compass.
Condition: Improper Installation
Due 13 April 2006
Resolved 7 April 2006
Fire Fighting › Fixed Fire Detection System › Approval
Issued 2 February 2006 Resolved
Need to provide proof that fixed fire detection system is certified by a professional engineer or classification society.
Condition: Unknown
Due 13 April 2006
Resolved 7 April 2006

Recorded names · 1

CHRIS ANN (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.