Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
20 August 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8469480
14 May 2026
Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8397597
13 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090947
12 June 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088656
13 June 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7874286
16 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7624353
13 July 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7646005
14 July 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411340
5 November 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161187
15 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161389
2 June 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904133
5 November 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849720
25 June 2019
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637814
10 July 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375244
30 November 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307551
24 August 2017
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6254004
15 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105819
16 June 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830663
14 April 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829306
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 November 2025
Resolved
If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed. The wood floor within the forepeak was found to be rotted. Renew the floor and allow for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 28 May 2026
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 November 2025
Resolved
Bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Clean the bilge beneath the shaft and remove the delaminated fiberglass to allow for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 28 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2025
Resolved
At each inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspections of machinery, fuel, and piping systems. Renew the fuel fill hose due to cracking.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 28 May 2026
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 July 2022
Resolved
Means to secure ventilation to pre-engineered fixed fire extinguishing system should be readily available. Provide means to properly secure ventilation.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 14 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 July 2022
Resolved
Each life buoy must be marked in clearly legible block capital letters with the vessel's name. Life buoy on board was not marked with vessel name.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 14 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 July 2021
Resolved
Gauges to indicate jacket water discharge temperature and lubricating oil pressure must be provided for all propulsion engines installed in a vessel. Vessel did not have gauges readily visible at operating station nor on the engine as allowed by Sector SE New England special considerations for launch vessels. Install gauges to satisfaction of CG marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2021
Resolved 19 August 2021
Resolution: Gauges were installed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2020
Resolved
Found life ring not in serviceable condition, replace.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 June 2020
Resolved 2 June 2020
Resolution: New life ring installed same day properly outfitted.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 25 June 2019
Resolved
Address faulty alarm on the engine alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 9 July 2019
Stability › Severe Wind/Roll › General
Issued 24 August 2017
Resolved
SST test to gain back 1 passenger lost due to repower weight increase on vessel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 September 2017
Resolved 28 September 2017
Resolution: No SST test to be completed at this time.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 June 2016
Resolved
Properly mount fire extinguisher in approved fitting bracket
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 23 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2016
Resolved
Replace expired asprin.
Condition: Placed in Improper Service
Due 30 June 2016
Resolved 16 June 2016
Resolution: Replaced expired asprin.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 June 2016
Resolved
Prove proper portable fire extinguisheer servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Prove proper portable fire extinguisheer servicing.