CARRIE ANNE

CARRIE ANNE is a 1981 towing vessel. The Coast Guard has recorded 12 inspections since 1999, most recently in April 2022, along with 62 deficiencies and 2 operational controls.

Records from 1999 to 2022. Most recent: inspection, 26 April 2022.

Built
1981
Last inspected
26 April 2022
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 April 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 12 calendar years (1999–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK9186
204011
Flag
UNITED STATES
Maury page id
psix-204011

Documentation record

Registered dimensions (L × B × D)56.5 ft × 22.0 ft × 8.7 ft
Registered tonnagegross 72 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderU.S. STEEL SHIPYARD, INC. · LAROSE, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 July 2025 · expires 31 July 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

26 April 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7438724
22 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7179039
23 April 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6942719
17 December 2019 Initial Certification · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6889805
3 October 2018 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6559774
5 September 2013 Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4707159
7 June 2010 Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3760279
24 September 2009 MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3602718
6 September 2006 MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2792590
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998909
5 July 2001 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522452
27 August 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 443497

Deficiency record · 62

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 May 2022 Resolved
Provide 12 total day / night visual distress signals prior to crossing the boundary line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 12 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2022 Resolved
The port SSG supply and return line are worn and missing chafing gear. Renew fuel lines with approved hoses.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 6 June 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 April 2022 Resolved
A towing vessel inspected under the USCG option must undergo annual inspection with 3 months of the anniversary date. Vessel is not to engage in towing vessel operations until an annual inspection is completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 12 May 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2021 Resolved
The fire main must have a sufficient number of fire hydrants with attached hose. Port side fire hose has a leak. Replace.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2021
Resolved 23 April 2021
Resolution: Received satisfactory evidence of replacement fire hose.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 April 2021 Resolved
The following alarms must be provided: high bilge levels, low hydraulic steering fluid. Alarms do not activate on the bridge. Repair. Crew member must conduct regular engine room rounds until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 29 April 2021
Resolution: Tested alarm found Sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2021 Resolved
Towing vessels must carry the minimum number of portable fire extinguishers. Fire extinguisher in berthing area mounted improperly. Repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 29 April 2021
Resolution: Added fire ext to vessel
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2021 Resolved
Connections and terminations must be suitable for the installed conductor. Starboard generator battery terminals loose, battery boxes not secured and macerator pump switch for MSD exposed. Make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 29 April 2021
Resolution: Installed new cover switch
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 March 2020 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies, including recovering persons from the water. The crew was unfamiliar with the man overboard procedures contained in the Health & Safety Plan. No means were present onboard for recovering an unconscious person from the water. Revise the emergency procedures as necessary and provide means to safely recover a person from the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 23 April 2020
Resolution: Procedures are in place
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 March 2020 Resolved
The vessel may be deemed structurally sufficient if it has been in satisfactory service and the OCMI does not question the structure. (a) Severe corrosion of the port side shell was found in the aft corner of the engine room, near the water line. Multiple small doubler plates were present in the vicinity. One transverse frame in the vicinity was previously cropped and inserted at the deck/side shell connection with insufficient welds. Investigate the extent of corrosion and provide a repair proposal. (b) The bilges were found covered in a combination of scaling, rags, and water. Clean the bilges to permit proper inspection of the hull and internal structure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2020
Resolution: Repairs made to side shell IWO engine room 3 ft above waterline
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 March 2020 Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel to an engine or generator. The fuel shutoff valve did not close fully when remotely activated. Demonstrate proper remote operation of the shutoff valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: Proper operation of shutoff was satisfactorily demonstrated.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 March 2020 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. The hydraulic oil tank sight glass was found cracked. Replace the sight glass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: New sight glass properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2020 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it rolling under sea conditions. The wheeled semi-portable extinguisher was not attached to the bulkhead or deck. Properly secure the extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 18 March 2020
Resolution: Semi-portable extinguisher securely chained in place on bow deck.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 March 2020 Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard, or rail. The #1 and #2 steering pumps in the aft port corner of the engine room had exposed rotating shafts. Install proper guards on both steering pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 18 March 2020
Resolution: Proper machinery guards have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2020 Resolved
Electrical systems and equipment must function properly and minimize fire and shock hazards. The #2 steering pump motor control box cover was missing and wiring was exposed. Properly install cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 18 March 2020
Resolution: Cover was properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2020 Resolved
Electrical equipment must be suitably protected from wet and corrosive environments. The battery box aft of the air receiver on the port side of the engine room was found with a substantial amount of liquid inside. Drain battery box, replace battery if necessary, and properly secure box cover to prevent further liquid ingress.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 18 March 2020
Resolution: Battery box cleaned and properly reinstalled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 March 2020 Resolved
Each vessel must have a fixed or portable fire pump. Only 2 of the 4 fixed pump mounts were properly attached to the mounting platform. Properly mount the fire pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2020
Resolved 18 March 2020
Resolution: Fire pump properly mounted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 March 2020 Resolved
The towing lights prescribed in the Inland Navigation Rules must be visible at a minimum range of 2 miles. The upper towing light platform was found angled downward. Demonstrate that the towing light satisfies the required minimum visible range.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2020
Resolved 18 March 2020
Resolution: New nav light bracket installed; nav light properly mounted horizontally.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2020 Resolved
Pressure vessels must be externally examined annually. The water heater tank in the fwd stbd corner of the engine room was found with serious corrosion around its base. Replace the tank or demonstrate the tank is in suitable condition for continued service via pressure test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2020
Resolved 18 March 2020
Resolution: New water heater tank properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 February 2020 Resolved
If more than one lifebuoy is carried, at least one must not have a lifeline attached. Both lifebuoys onboard had lifelines attached. Remove the lifeline from one of the lifebuoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Line removed from stbd life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 February 2020 Resolved
Every vessel with an inflatable survival craft must have posted launching and inflating instructions near each craft. No instructions were posted onboard. Provide proper instructions in the vicinity of the liferaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 2 March 2020
Resolution: Launching instructions posted just fwd of life raft.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 February 2020 Resolved
EPIRBs must be stowed in a float-free configuration. The EPIRB hydrostatic release unit was not marked with an expiration date. Provide new proper hydro release unit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Hydrostatic release installed and properly marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2020 Resolved
The owner/operator/master must ensure the vessel’s fire extinguishing and detection equipment complies with all applicable requirements. (a) The heat detector above the stbd engine was found hanging from the overhead by its signal cable. Properly mount the heat detector. (b) The semi-portable extinguisher onboard was found to consist of two 20-B:C rated extinguishers. Provide a proper extinguisher with a minimum of a 160-B rating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Heat detector properly re-mounted. New 160-B:C extinguisher provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 February 2020 Resolved
Machinery and electrical systems must be maintained to provide for safe operation and safety of personnel onboard. The electrical windings on both port and stbd generators were found coated in oil, dirt, and dust. Properly clean/repair/replace generator windings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Generator windings cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 February 2020 Resolved
Electrical systems and equipment must function properly and minimize fire and shock hazards. The gray distribution panel on the engine room fwd bhd near the stbd generator had an unsecured cover and was missing blanks at the bottom. Properly secure the distribution panel cover and install blanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 2 March 2020
Resolution: Cover has been secured. Blanks have been installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 February 2020 Resolved
Flammable and combustible products must not be stored in machinery spaces unless in a suitable container. (a) Containers of starter fluid were found at the bottom of the exhaust stack in the engine room aft bulkhead, and the stack was covered in oil residue. Properly store all flammable/combustible products and clean exhaust stack. (b) The waste oil tank on the engine room port bhd was found to have 3 open pipes/access openings on the top of the tank with a flexible hose entering the tank through 1 opening. Properly close/secure all tank pipes/access openings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Flammable/combustible materials removed from vessel. Lube oil tank accesses have been plugged.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 February 2020 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Substantially oil-soaked absorbent pads were found below both port and stbd generators. Repair/replace generators to prevent excessive leaks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Absorbent pads removed. Port gen operating with no noticeable leaks.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 February 2020 Resolved
The vessel shall comply with the Inland Navigation Rules. The towing lights did not illuminate. Prove proper operation of all required navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: All nav lights properly illuminate.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 February 2020 Resolved
The vessel must have low lube oil pressure and high cooling water temperature alarms for auxiliary generators; a summary alarm at the operating station is permitted if local alarms are provided. A summary alarm was located on the bridge, but no local alarms were present. Provide all required generator alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 2 March 2020
Resolution: Local lube oil and cooling water alarms have been installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 February 2020 Resolved
The vessel must have an alarm to indicate low hydraulic steering fluid levels. No such alarm was provided onboard. Install and prove proper operation of an audible and visual low hydraulic steering fluid level alarm at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 2 March 2020
Resolution: Hydraulic level alarm is installed at the operating station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 February 2020 Resolved
The required high bilge level alarm must be visible and audible at the operating station. The bilge alarm failed to activate. Prove proper operation of the bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
Resolution: Bilge alarm op tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 February 2020 Resolved
There must be an installed bilge pump for emergency dewatering. The platform to which the bilge pump was mounted was found seriously wasted and the pump was not actually attached. Properly mount the bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 2 March 2020
Resolution: Platform replaced & pump properly mounted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 February 2020 Resolved
Suitable closure devices must be provided for hull penetrations which may allow water to enter the vessel. The forepeak hatch gasket was found to be foam. Replace gasket with suitable material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 2 March 2020
Resolution: New rubber gasket has been installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 February 2020 Resolved
No person may operate any vessel with toilet facilities unless it is equipped with an operable Type I, II, or III marine sanitation device. No labeling was provided to indicate the sewage tank in the engine room is a certified MSD. Provide proof that the sewage tank is certified or replace the tank with a certified MSD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 20 March 2020
Resolution: Existing MSD does not require MSC review/approval.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2020 Resolved
EAP information material, the crewmember assistance hotline number, and the company policy regarding drug and alcohol use must be displayed and distributed. No such information was posted onboard. Properly post all required information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 2 March 2020
Resolution: Required information posted on mess deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 2 March 2020
Resolution: MIS reports are submitted by consortium on behalf of company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2020 Resolved
Employers must ensure they and their crewmembers meet the requirements of 46 CFR Part 16. The company’s drug and alcohol program does not meet all requirements. Update the policy to comply with all requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 18 March 2020
Resolution: Drug & alcohol plan updated to satisfy regs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2018 Resolved
Employers shall ensure that all crew members are enrolled in a drug and alcohol program. Employer must provide proof that the vessel and all crew members are in compliance with 46 CFR Part 16.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Superseded by defs from Activity 6889805.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 October 2018 Resolved
A towing vessel must be manned in accordance with 46 CFR Part 15 for the voyage it is on. Vessel was on a voyage greater than 12-hours with only a master and unlicensed deckhand onboard. Provide proof of proper manning prior to getting underway.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Vessel is conducting 12-hour ops.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 October 2018 Resolved
Vessel’s fire detection system must be installed and certified by a registered professional engineer, a NICET qualified technician, or an approved classification society. Vessel does not have proof that the system has been certified. The fire detection panel is also showing a fault in the system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Received ltr from NICET tech.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2018 Resolved
Vessel must have either an installed fixed fire-extinguishing system or a 160-B semi-portable fire extinguisher to protect the machinery space, neither system is available onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2018
Resolution: A new semi-portable B-60 fire extinguisher was provided and temporarily stowed on the aft deck in way of the machiunery space entrance. Upon arrival at homeport, the 160-B should be mounted in a more permanent manner to the satisfaction of the Inspector
01 - Certificates & Documentation › 013 - Documents › Tables of working hours
Issued 5 October 2018 Resolved
The master must keep an accurate list of crewmembers onboard and their duties/responsibilities in the event of an emergency. The date and time a watch stander assumes and is relieved during a watch must also be recorded. Vessel has no records.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Vessel has established electronic TVR.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 5 October 2018 Resolved
Safety orientation must be conducted prior to getting underway and logged. No records were available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Vessel has established electronic TVR.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 5 October 2018 Resolved
An industrial type first aid kit must be provided. The contents of the kit onboard were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Two new first aid kits were provided onboard that seemed suitable for the size of the crew and the operating conditions.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 5 October 2018 Resolved
Prior to getting underway an appropriate navigational assessment must be conducted and recorded. No records were available.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Vessel has established electronic TVR.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 5 October 2018 Resolved
Navigational safety training in accordance with 46CFR140.645 must be conducted prior to getting underway and logged.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Vessel has established electronic TVR.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 October 2018 Resolved
Current Coast Pilot, tide tables, and current tables shall be provided onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: All pubs now onboard.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 5 October 2018 Resolved
Means must be provided to show the rudder angle. The vessel’s rudder angle indicator was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 2 March 2020
Resolution: Demonstrated successful RAI operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 October 2018 Resolved
All PFDs must be fitted with a light. All current PDF lights are expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: All PFD's fitted with a light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 October 2018 Resolved
All PFDs must be marked with the vessel’s name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 24 October 2018
Resolution: All PFD's are marked with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 5 October 2018 Resolved
Immersion suits must be provided for each member onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Immersion suits provided for 4 persons.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 October 2018 Resolved
No survival craft is provided onboard. Vessel is restricted to operating in only protected waters.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Survival craft is provided and properly mounted.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 October 2018 Resolved
Reliable means must be provided for notification when an emergency condition exists. Vessel was unable to demonstrate if the operating station or machinery space was equipped with the alarms and monitoring devices required by 46CFR143.230.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Superseded by defs from Activity 6889805.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 October 2018 Resolved
Each towing vessel must be fitted with a general alarm. Vessel does not have a general alarm installed onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 20 February 2020
Resolution: Satisfactorily tested general alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2018 Resolved
Vessel must provide proof of the pressure vessel’s MAWP and verify that a properly fitted relief valve is provided.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 23 April 2020
Resolution: New UPV onbaord
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 5 October 2018 Resolved
The MSD must have a proper certification label and operating placard. No approval or certification label was provided. Provide proof that the MSD onboard is an approved type.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 20 February 2020
Resolution: Superseded by defs from Activity 6889805.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 5 October 2018 Resolved
Provide oil transfer procedures.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 24 October 2018
Resolution: Transfer procedures onboard.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 5 October 2018 Resolved
When operating in a no discharge zone the MSD overboard valve must be closed and secured. Valve was not secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 24 October 2018
Resolution: MSD secured.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 October 2018 Resolved
Vessel’s name and hailing port must be properly marked on the exterior of the vessel. Vessel underwent name change and has not updated the name and hailing port on the exterior of the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 20 February 2020
Resolution: Vessel's current name and hailing port are properly marked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 October 2018 Resolved
Bilge alarm is inoperable
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2018
Resolution: Tested the bilge alarm satisfactory.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 October 2018 Resolved
All bilge and void spaces must be kept clear of combustible liquids. Remove oil from bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Oil from bilge removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2018 Resolved
Make all voids open and available for inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 24 October 2018
Resolution: All voids inspected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2018 Resolved
Remove water from the aft potable water tank and make available for inspection
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 15 October 2018
Resolution: Tank was drained and inspected. No issues identified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.