MAURY USCG vessel records Sign in
← All vessels

BIG SHOT

BIG SHOT is a 1981 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1988, most recently in May 2026, along with 156 deficiencies, 1 operational control and 1 casualty investigation in 2022.

Records from 1988 to 2026. Most recent: inspection, 19 May 2026.

Built
1981
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM8775
204118
Flag
UNITED STATES
367133750, 367795460
Maury page id
psix-204118

Inspections, by type

…with no type recorded7
Years with a record 34 calendar years (1988–2026)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.8 ft × 16.6 ft × 6.9 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEFENDER YACHT CORP · MIAMI, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM8775MMSI 367133750 · active · compulsorily equipped · granted 26 March 2022, expires 26 March 2032
WDJ6209MMSI 367795460 · active · compulsorily equipped · granted 20 June 2017, expires 20 June 2027 · licensed under a name not among this hull’s recorded names (not shown)
WDD3605MMSI 367133750 · expired · compulsorily equipped · granted 9 August 2006, cancelled 15 October 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCY3204MMSI 366748030 · expired · compulsorily equipped · granted 22 April 1998, cancelled 28 June 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

19 May 2026 Administrative Inspection · DAPI Audit · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8377136
12 August 2025 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8207348
28 June 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8169371
13 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8135130
23 April 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7899969
22 August 2023 Internal Structural Exam · Deficiency Check · Drydock Extension
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7774362
19 April 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7676235
4 August 2022 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7525540
16 March 2022 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7413085
2 September 2021 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7306108
17 July 2021 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7260070
25 May 2021 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7212039
22 September 2020 Annual Inspection · Administrative Inspection · Deficiency Check · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7106368
3 October 2019 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6826593
29 August 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6799046
14 May 2019 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6684397
23 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570680
10 July 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6477018
19 September 2017 Hull Examination · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6270132
22 June 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6177710
6 April 2017 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6119903
6 September 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5993815
16 June 2016 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5904197
13 September 2015 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 5720560
28 August 2014 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4998560
24 June 2014 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4906114
25 August 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4126506
5 August 2008 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3286011
17 June 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3222542
12 July 2006 Internal Structural Exam · Examination of Repairs · Hull Examination · Simplified Stability Test · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2888322
5 May 2005 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2349484
22 July 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2145391
15 June 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2098856
29 April 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2054402
10 July 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1842157
13 May 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1793461
24 April 2002 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1608576
23 April 2001 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1472875
23 August 2000 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 820939
9 May 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821911
30 March 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1415404
16 June 1999 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 123884
11 May 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404776
21 May 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473269
7 April 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1375336
16 December 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1118911
22 April 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374978
30 April 1996 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392457
24 October 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 884412
25 August 1995 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448682
19 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 171479
16 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465822
19 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863120
8 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863003
16 June 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154162
24 March 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838576
8 March 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834855
1 April 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963035
19 February 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261840
30 July 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1248060
20 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924041
27 February 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1235919
8 August 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221220
25 April 1990 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 928088
14 February 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216531
13 February 1989 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 888534
24 February 1988 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1029489

Deficiency record · 156

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2025 Resolved
A periodic examination made in accordance with the requirements of this subpart shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudders, through hull fittings, sea valves and strainers, and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. MI identified port and starboard cutlass bearings on shaft tubes were worn to an unsatisfactory condition. Vessel to replace no later than 31 January 2026 and is authorized to continue operation until this date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2026
Resolved 16 August 2025
Resolution: Vessel replaced both cutlass bearings, all satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2024 Resolved
The vessel must have a Cat I EPIRB properly installed to float free. The EPIRB battery and hydro release are expired. Vessels is restricted to less than 3NM from shore or not more than six (6) passengers beyond 3NM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2024
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 August 2023 Resolved
Approximate one square foot area at main deck, port stern corner, of water intrusion near scupper resulting in wood decay of deck. No immediate threat of deck failure. Allowed 30 days to affect permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 5 September 2023
Resolution: Area of rotting port stern deck was satisfactorily replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 August 2023 Resolved
Identified area of termite infestation in overhead, starboard stern corner of stern void. Exposed termite tunnel extended from starboard, overhead corner down to bilge and towards starboard rudder post. Required vessel owner to provide exterminator report to determine extent/degree of infestation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 24 August 2023
Resolution: Received termite inspection report. Termites limited to only the above area, treated and eliminated. No permanent damage identified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 April 2023 Resolved
Inspected small passenger vessels that operate on coastwise or oceans routes must have an interconnected fire detection system installed in an all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces to be installed by December 27th, 2022. Provide evidence of installation and that the fire-detection system has been approved. Until installed, the vessel is now restricted to a Limited Coastwise route.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2023
Resolved 2 May 2023
Resolution: Received photographs of installed and approved fire-detection devices; satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 April 2023 Resolved
The inspected vessel is absent of the appropriate FCC documentation. Provide evidence of valid FCC Safety Radiotelephony Certificate
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 26 April 2023
Resolution: Received photograph of valid FCC Safety Radiotelephony Certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 April 2023 Resolved
The construction and arrangement of a vessel must allow for the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Inspector observed the hatch leading into the Engine Room not having a securing device. Install a latch or securing device for this hatch to provide adequate safety for crew and passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 26 April 2023
Resolution: Received photograph of installed latch for the hatch leading into the Engine Room.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 25 May 2021 Resolved
Provide proof of drug and alcohol testing program enrollment and means of testing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Provided proof of DAPI enrollment and alcohol testing strips
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2021 Resolved
Attach waterlights to life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2021
Resolution: Waterlight properly affixed to life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2021 Resolved
Properly affix retro to life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: Retro installed on life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021 Resolved
Several life jacket lights are inoperative, prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2021
Resolution: Lights installed on life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021 Resolved
Properly store life jackets so adult and child life jackets are separated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Life jackets properly separated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2021 Resolved
Properly label breakers on the aft main cabin and CO2 control box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2021
Resolution: Labels installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021 Resolved
Properly secure unsupported piping in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Piping properly secured.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 May 2021 Resolved
Remove excessive water and oil from condensate drain void and engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2021
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 May 2021 Resolved
Provide proof of valid EPIRB registration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Provided proof of valid EPIRB registration.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 May 2021 Resolved
Provide proof of a valid radio telephony certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Provided proof of a valid FCC radio safety Cert.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 May 2021 Resolved
Provide proof of nav rules publication.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Nav rules publication provided.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 May 2021 Resolved
Label fuel tank shut off valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Fuel tank valve shut off valves labeled.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2020 Resolved
Vessel's fixed CO2 cylinder is not secured and manual actuator control lines are disconnected. Properly install means of activation and properly secure and provide service report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2020
Resolution: Vessel fixed CO2 cylinder secured and manual control lines connected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 September 2020 Resolved
Replace expired hydrostatic release for EPIRB. Each disposable hydrostatic release unit must be marked with an expiration date of two yeats after the date on which the unit was instaled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2020
Resolution: Hydrostatic release for EPIRB corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 September 2020 Resolved
Properly secure Engine Room power panel and label breakers. All electrical equipment and circuits must be clearly marked and identified. Installed electrical equipment must also be installed to be suitable for roll, pitch, and vibration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2021
Resolution: Panel secured and properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2020 Resolved
Install Engine Room batteries in a Battery box. The batteries must be effectively screened by a cage or similar structure to minimize the danger of accidental spark.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2021
Resolution: Battery boxes installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2020 Resolved
Remove excessive oil from generator windings. Excesive oil, trash, debris, and other matter might create a fire hazrd, clog bilge pumping systems, or block emergency escapes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2021
Resolution: Fire hazards removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2020 Resolved
Install cover over stern void receptacle to provide adequate protection and proper safety.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 December 2020
Resolution: Cover installed on stern void receptacle.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 22 September 2020 Resolved
Repair broken ladder rong in bow void. The ladder must be capable of being rolled up for storage and able to unroll freely when neccesary. It must also adhere to the strength requirements listed in 46CFR160.017-17.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2021
Resolution: New ladder provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 September 2020 Resolved
Provide proof of valid EPIRB Registration through the FCC as set forth in 47CFR80.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2020
Resolution: Master provided proof of valid EPIRB registration.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2020 Resolved
Provide proof of valid FCC Safety Radio telephony certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 1 June 2021
Resolution: New cert provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 September 2020 Resolved
Replace broken pilot house windows. At next drydock.
Action required: 705 - Other - as specified
Resolved 30 September 2021
Resolution: Broken windows replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 September 2020 Resolved
Properly install pilot house stern paneling on bulk head no later than next drydock.
Action required: 705 - Other - as specified
Resolved 30 September 2021
Resolution: Missing paneling installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 May 2019 Resolved
Repair or replace the bow life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 July 2019
Resolution: Owner repaired the bow life float, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 28 May 2019 Resolved
Repair radar prior to operating at night or during reduced visibility.
Action required: 705 - Other - as specified
Resolved 29 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019 Resolved
Flexible hose shall be provided with suitable connection fittings and shall be provided with suitable connection fittings and shall have a high resistance to salt water, petroleum oils, heat, and vibration. Main diesel engine(MDE) fuel return lines and fuel oil tank supply lines were severely dry rotted. Replace affected fuel lines to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 May 2019
Resolved 28 May 2019
Resolution: Wasted lines replaced; all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2019 Resolved
All piping, valves, and fittings of ferrous materials shall be protected inside and outside against corrosion. Engine room Fixed CO2 Fire Extinguishing System had severe corrosion in fittings. Replace affected piping to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2019
Resolved 22 July 2019
Resolution: Owner replaced wasted piping on fixed CO2 system, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2019 Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. Both the port and starboard forward engine mount pedestal brackets for the Center MDE were wasted to a razor's edge. Replace affected engine mounts in kind to the satisfaction of the attending Coast Guard Marine Inspector prior to using the center engine.
Action required: 705 - Other - as specified
Resolved 22 July 2019
Resolution: Both the port and starboard forward engine mount pedestal brackets for the Center MDE were wasted. Owner replaced engine mounts, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 May 2019 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. All MDE alternator belts were removed. The Center MDE's alternator was severely corroded that the outer shell was wasted away exposing only the stator winding and core. All machinery was freshly painted and there was no means to charge any start batteries on board without use of the vessel's single ship service diesel generator (SSDG). Repair or replace MDE alternators to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2019
Resolved 22 July 2019
Resolution: Owner replaced MDE alternators, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2019 Resolved
If fire is in machinery space shut off fuel supply in emergency situation. Emergency fuel shut off valves were wasted and broke when tested. Replace fuel shut off valve connections and grab lines to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 May 2019
Resolved 5 June 2019
Resolution: New fuel shut off valve access plates installed and tested; all sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 May 2019 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Excess oil was noted in engine room bilge. Remove all excess oil to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 May 2019
Resolved 28 May 2019
Resolution: Excess oil removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 May 2019 Resolved
Examine and test by operation all watertight closures in the hull, decks, and bulkheads. The vessel's forward berthing port lights had no dawgs and were only held in place with standard caulking. Provide means for securing port lights to ensure vessel's watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 May 2019
Resolved 28 May 2019
Resolution: Port light properly secured and sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2019 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessel's forward berthing bilge pump was not secured and tied off with line for retrieval. Ensure bilge pump is secured and prove proper operation to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 May 2019
Resolved 28 May 2019
Resolution: Bilge pump properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 May 2019 Resolved
Gages to indicate engine cooling water discharge temperature shall be provided. The center MDE had a broken and disconnected jacket water temperature sensor. Provide appropriate sensor and show satisfactory operation of the gage to the attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 17 May 2019
Resolved 22 July 2019
Resolution: Owner relpaced Jacket water temperature sensor, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 May 2019 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Forward life float missing painter with float free link. Provide painter with float-free link for forward life float. Vessel is limited to operating with no more than 44 persons on board.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 May 2019
Resolved 22 July 2019
Resolution: Owner provided painter and link for forward life float.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 10 July 2018 Resolved
A vessel must comply with the structural design requirements of this subchapter. The vessel's bulkhead between the storage room and fwd space has areas of rot, delamination, and fractures. Vessel owner is required to conduct repairs to the bulkhead to the satisfaction of the attending CG Marine Inspector. Due by 24JUL2018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 2 August 2018
Resolution: Correced; all SAT.
Construction/Loadline › Hull › Keel
Issued 19 September 2017 Resolved
Repair Fiberglass delaminatation on the aft end of the keel (Port/STBD) near the center engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2017
Resolved 26 September 2017
Engineering › Sea-water System (primary cooling) › Valve
Issued 19 September 2017 Resolved
Repair Live well through hull ball valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2017
Resolved 26 September 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 September 2017 Resolved
Repair the hole in the engine room FWD bulkhead.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2017
Resolved 26 September 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 April 2017 Resolved
Complete a credit COI exam. Vessel COI expired on 22Mar17
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2017
Resolved 22 June 2017
Resolution: COI Exam completed.
Documentation › Certificates/Documents › FCC SSL
Issued 16 June 2016 Resolved
Provide an SSL for the vessel in date.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 June 2016
Resolution: Vessel provided SSL
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 June 2016 Resolved
Vessel User Fees not paid up...
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 June 2016
Resolution: Paid
Engineering › Steering Gear System › Bracket/Clamp
Issued 16 June 2016 Resolved
Replace the steering rudder table.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2016
Resolved 23 June 2016
Resolution: Replace with .5 inch steel.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 16 June 2016 Resolved
Renew Retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Vessel renewed retro tape
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 June 2016 Resolved
Provide Alcohol test equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Vessel provided alcohol test equipment
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 June 2016 Resolved
Provide a US Coast Pilot for the vessel.
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Vessel provided coast pilot
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 June 2016 Resolved
Provide Lighting for the Egress of berthing.
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 June 2016
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 28 August 2014 Resolved
repair damage to deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 October 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 June 2014 Resolved
Provide completed valid fixed fire system service report. Current report is incomplete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2014
Resolution: Vessel had system properly serviced with a proper completed report.
Engineering › Bilge Water Management System › Interface Detector
Issued 24 June 2014 Resolved
Prove proper operation of bilge alarms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2014
Resolution: Vessel performed sat test of bilge alarms.
Engineering › Fuel Oil Service System › Valve
Issued 24 June 2014 Resolved
Replace fwd engine fuel oil emergency shut off valve handle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2014
Resolution: Vessel replaced valve.
Engineering › Steering Gear System › Rudder
Issued 24 June 2014 Resolved
Clean and make rudder foot assembly available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2014
Resolution: Rudder foot was sat inspected.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 June 2014 Resolved
Provide valid FCC radio telephony certificate.
Action required: 705 - Other - as specified
Due 8 July 2014
Resolved 28 August 2014
Resolution: Receive valid FCC certification.
Lifesaving › Lifefloat › Float-free Link
Issued 17 June 2008 Resolved
Replace missing weak link on forward life float located forward of pilot house.
Due 17 July 2008
Resolved 19 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 June 2008 Resolved
Repair and prove operation of anchor light.
Due 17 July 2008
Resolved 19 June 2008
Lifesaving › Lifefloat › Paddle
Issued 17 June 2008 Resolved
Replace missing paddles on lower life float topside of pilot house.
Due 17 July 2008
Resolved 19 June 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 17 June 2008 Resolved
Prove operation of forward high level alarm.
Due 17 July 2008
Resolved 19 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 June 2008 Resolved
Repair leak on port exhaust.
Due 17 July 2008
Resolved 19 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 17 June 2008 Resolved
Replace 23 missing lights on life jackets.
Due 17 July 2008
Resolved 19 June 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 June 2008 Resolved
Make aft bulkhead in engine room water tight/no wires.
Due 17 July 2008
Resolved 19 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 May 2005 Resolved
Provide evidence of compliance with drug and alcohol testing program for all personnel employed on vessel. (46 CFR Part 16)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 May 2005 Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Communications › Audible Communications › Horn/Whistle
Issued 5 May 2005 Resolved
Demonstrate proper operation of installed horn sound signal device. (33 CFR Part 86)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 5 May 2005 Resolved
Repair port and starboard propulsion engine throttle/marine gear control heads as originally fitted or equivalent. (46 CFR 184.620)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Communications › Radio Communications › EPIRB
Issued 5 May 2005 Resolved
Replace expired hydrostatic release on CAT 1 406 mhz EPIRB (46 CFR 180.64)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Lifesaving › Lifefloat › Paddle
Issued 5 May 2005 Resolved
Secure paddles to lifefloats by suitable means and re-stencil vessel name on each paddle. (46 CFR 180.200)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Lifesaving › Lifebuoys › Serviceable
Issued 5 May 2005 Resolved
Replace clip on water light lanyard with a clip of corrosion resistant material. (46 CFR 180.70)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 May 2005 Resolved
Secure portable fire extinguisher bracket in pilot house. (46 CFR 181.500)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 May 2005 Resolved
Repair leaks in starboard propulsion engine muffler and prove tight. (46 CFR 182.430)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 5 May 2005 Resolved
Make all penetrations and openings in machinery space overhead, for and aft bulkheads vapor tight. (46 CFR 177.405)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 May 2005 Resolved
Provide for suitable means to close, and make vapor tight, all machinery space ventilators. (46 CFR 182.465).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 May 2005 Resolved
Provide/install suitable machinery guards on center propulsion shaft and port/starboard propulsion engine flywheels. (46 CFR 177.960)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 May 2005 Resolved
Adjust all propulsion shaft glands to prevent excessive leakage. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Engineering › Bilge Water Management System › Pump
Issued 5 May 2005 Resolved
Demonstrate proper operation of all required bilge pumps and bilge high level alarms on vessel. (46 CFR 182.530)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 5 May 2005 Resolved
Demonstrate proper operation of installed auxiliary generator prime mover and ships electrical service system. (46 CFR 176.800).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 May 2005 Resolved
Remove all non-approved solid copper electrical conductors from vessel. All modifications to vessel's electrical service systems are subject to plan submittal, review and approval in accordance with 46 CFR 176.700 and 46 CFR 183.115(c).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 May 2005 Resolved
Provide suitable cover for electrical junction box in main salon. (46 CFR 183.330)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Personnel › Training › Familiarization Training
Issued 5 May 2005 Resolved
Conduct crew training required by 46 CFR 185.420 and perform fire, man overboard and abandon ship drills as required by 46 CFR 185.520 and 524.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 15 March 2007
Lifesaving › Hand Flares › Expired
Issued 15 June 2004 Resolved
Provide 6 serviceable hand held red flare distress signals and smoke signals approved in accordance with 46 CFR 160.021 and .037as required by 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 22 July 2004
Lifesaving › Lifebuoys › Serviceable
Issued 15 June 2004 Resolved
Provide one (1) serviceable ring life buoy in accordance with 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 22 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 June 2004 Resolved
Mark 09 Adult Type I PFDs with Type I retro-reflective material approved in accordance 46 CFR 164.018 as required by 46 CFR 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 15 June 2004 Resolved
Remove dead-ended electrical conductors/cables on Type II sewage system or terminate to a suitable electrical junction box in accordance with 46 CFR 183.05-50.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 22 July 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 June 2004 Resolved
Secure propulsion engine starting batteries to protect against shifting as required by 46 CFR 183.05-20.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 22 July 2004
Engineering › Lubricating Oil Service System › Gauge
Issued 15 June 2004 Resolved
Renew oil pressure sending unit supply non-metallic flex hose assembly in accordance with 46CFR182.720.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 22 July 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 June 2004 Resolved
Renew double clamps on all propulsion engine salt water cooling system flex hose assemblies. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 22 July 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 June 2004 Resolved
Renew port deck rail support, port side, 4 feet aft from stem.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 22 July 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 June 2004 Resolved
Renew exhaust piping insulation blanket on port propulsion engine (46 CFR 177.960)
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 22 July 2004
Construction/Loadline › Hull › Keel
Issued 29 April 2004 Resolved
Repair fractured keel attachment to hull IWO port and stbd midship area. LEGACY COMPONENT DESC: Keel Plate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 April 2004 Resolved
Repair port and stbd strut blocks, renew as original. LEGACY COMPONENT DESC: Strut
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Engineering › Steering Gear System › Rudder Bearing
Issued 29 April 2004 Resolved
Renew port and stbd rudder tubes. LEGACY COMPONENT DESC: Rudder
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Construction/Loadline › Hull › Bracket
Issued 29 April 2004 Resolved
Replace aft lazerette door. LEGACY COMPONENT DESC: Door
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Construction/Loadline › Hull › Hull Plating
Issued 29 April 2004 Resolved
Repair delamination in lazerette both port and stbd. LEGACY COMPONENT DESC: Delamination
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 29 April 2004 Resolved
Repair port and stbd light covers. LEGACY COMPONENT DESC: Light Covers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Construction/Loadline › Hull › Hull Plating
Issued 29 April 2004 Resolved
Repair fracture below stbd port light 12' aft of stem. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Communications › Radio Communications
Issued 13 May 2003 Resolved
Provide hydrostatic release for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner provided hydro release.
Engineering › Sea-water System (primary cooling)
Issued 13 May 2003 Resolved
Replace flexible hose on center engine salt water seacock. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner replaced flexible hose.
Engineering › Sea-water System (primary cooling)
Issued 13 May 2003 Resolved
Replace flexible hose on stbd engine saltwater seacock. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner replaced flexible hose.
Accommodation/Occupational Safety › Occupational Safety
Issued 13 May 2003 Resolved
Repair exhaust insulation on all engines. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner repaired exhaust insulation.
Engineering › Fuel Oil Service System
Issued 13 May 2003 Resolved
Repair mechanical fuel shut offs on all engines. LEGACY COMPONENT DESC: Valve, Control
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner repaired mechanical fuel shut offs.
Communications › Alarms/Indicators
Issued 13 May 2003 Resolved
Repair high level bilge alarm in accommodation space. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner repaired high level bilge alarm.
Navigation › Piloting/Steering
Issued 13 May 2003 Resolved
Provide Tide/Current Tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 10 July 2003
Resolution: Owner provided tide/current tables.
Communications › Radio Communications
Issued 13 May 2003 Resolved
Provide emergency broadcast placard. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner provided emergency broadcast placard.
Accommodation/Occupational Safety › Occupational Safety
Issued 13 May 2003 Resolved
Repair rail stanchions both sides on the bow. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 10 July 2003
Resolution: Owner repaired rail stanchionson both sides of the bow.
Construction/Loadline › Hull
Issued 13 May 2003 Resolved
Repair vertical stiffener in lazarette. LEGACY COMPONENT DESC: Stiffener
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner repaired vertical stiffener.
Lifesaving › Rigid Liferafts
Issued 13 May 2003 Resolved
Provide markings on Lifefloat in 2" letters. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner properly marked lifefloat.
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 May 2003 Resolved
Replace First Aid Kit IAW 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 10 July 2003
Resolution: Owner replaced first aid kit.
Engineering › Fuel Oil Service System
Issued 13 May 2003 Resolved
Tighten fuel oil connections on all main supply lines. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner tightened fuel oil connections.
Stability › Watertight Integrity
Issued 13 May 2003 Resolved
Tighten shaft packing and all shaft couplings. LEGACY COMPONENT DESC: Shaft Packings
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner tightened shaft packing and couplings.
Electrical › Electrical Distribution System (service)
Issued 13 May 2003 Resolved
Rewire Bridge console with proper wiring as required by 46 CFR 183.340 & 183.10-20. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 10 July 2003
Resolution: Owner rewired bridge console with proper wiring.
Electrical › Electric Supply System (service)
Issued 13 May 2003 Resolved
Provide cable supports for anchor windlass (every 24"). LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 10 July 2003
Resolution: Owner provided cable supports for anchor windlass.
Engineering › Bilge Water Management System
Issued 13 May 2003 Resolved
Remove bilge slops.
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 14 May 2003
Resolution: Owner removed bilge slops.
Electrical › Lighting (service)
Issued 13 May 2003 Resolved
Remove flourescent lights in fwd accommodation or replace same with proper 110V lights.
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 10 July 2003
Resolution: Owner removed flourescent lights in fwd accommodation space and replaced with proper 110v lights.
Documentation
Issued 23 April 2001 Resolved
PROVIDE AND POST COI PRIOR TO OPERATION.
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Electrical
Issued 23 April 2001 Resolved
REMOVE FLUORESCENT LIGHTS IN ENGINE ROOM PRIOR TO 23MAY01.
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Lifesaving
Issued 23 April 2001 Resolved
INSTALL BLACK LINE ON LIFE RING PRIOR TO 23 MAY 01.
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Lifesaving
Issued 23 April 2001 Resolved
PROVIDE EPIRB REGISTRATION PRIOR TO 03MAY01 AND PRIOR TO OPERATING BEYOND 3NAUTICAL MILES OFFSHORE.
Condition: Unknown
Due 3 May 2001
Resolved 12 June 2001
Lifesaving
Issued 23 April 2001 Resolved
LABEL UPPER DECK "NO PASSENGERS ALLOWED" PRIOR TO 23MAY01.
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Lifesaving
Issued 23 April 2001 Resolved
RELOCATE LIFERING TO MAIN DECK PRIOR TO 23MAY01.
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Documentation
Issued 23 April 2001 Resolved
PROVIDE FCC OPERATORS PERMIT PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Documentation
Issued 23 April 2001 Resolved
PROVIDE FCC SAFETY CERTIFICATE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 23 April 2001
Resolved 12 June 2001
Navigation
Issued 23 April 2001 Resolved
PROVIDE NAVIGATION PUBLICATIONS IAW 46 CFR 184.420 PRIOR TO 23 MAY01
Condition: Unknown
Due 23 May 2001
Resolved 12 June 2001
Lifesaving
Issued 21 May 1998 Resolved
MAKE PROPER REPAIRS TO LIFEFLOAT SURFACE AS PER 46 CFR 180.200.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 May 1998 Resolved
PROVIDE FIRST AID KIT THAT MEETS REQUIREMENTS OF 46 CFR 160.041.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 May 1998 Resolved
PROVIDE SECOND STYLE LIFEJACKET PLACARD AS PER 46 CFR 185.514.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Construction/Loadline
Issued 21 May 1998 Resolved
PROVIDE 6 INCH COAMING ON WEATHERTIGHT DOOR AS PER 46 CFR 171.124.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Engineering
Issued 21 May 1998 Resolved
RENEW 30X30 MESH SCREEN ON FUEL TANK VENTS AS PER 46 CFR 182.15-35(D)
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 22 April 1997 Resolved
REGISTER VESSELS 406 MHz EPIRB WITH NOAA, AFFIX DECAL TO EPIRB ONCE RECEIVED. (46 CFR 180.64)
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 22 April 1997 Resolved
RENEW LIFEFLOAT SEA PAINTER LINE AS PER 46 CFR 180.137.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 25 August 1995 Resolved
REPAIR EXCESSIVE LEAKING AROUND CENTER SHAFT LOG.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Electrical
Issued 25 August 1995 Resolved
RENEW ALL ELECTRICAL WIRING AND CIRCUIT BREAKERS IN ENGINE ROOM.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Accommodation/Occupational Safety
Issued 25 August 1995 Resolved
RENEW SALT WATER SUPPLY PVC PIPING TO LIVE BAIT WELL.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
REPAIR OR RENEW DISCHARGED AND DAMAGED FIXED FIRE FIGHTING SYSTEM FOR ENGINE ROOM THAT MEETS COAST GUARD APPROVED STANDARDS AS PER NAVIC 8-87, CH1.F.4.c.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Electrical
Issued 25 August 1995 Resolved
INSTALL METAL WIRE CLAMPS FOR ALL OVERHEAD WIRES IN ENGINE ROOM AT INTERVALS OF 18".
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Unknown
Issued 25 August 1995 Resolved
PERFORM GENERAL HOUSEKEEPING OF ENGINE ROOM TO REMOVE RESIDUE OF FIRE DAMAGE.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 19 April 1994 Resolved
COMPLETE INSTALLATION OF THE REMOTE FUEL CUTOUT VALVE TO THE PORT PROPULSION ENGINE.
Condition: Unknown
Due 12 May 1994
Resolved 7 July 1994
Lifesaving
Issued 19 April 1994 Resolved
FABRICATE PERSONAL PROTECTION SHAFT GUARD FOR THE CENTERLINE PROPULSION SHAFT AT THE ENGINEROOM ACCESS HATCH.
Condition: Unknown
Due 12 May 1994
Resolved 7 July 1994
Accommodation/Occupational Safety
Issued 24 March 1993 Resolved
INSTALL DECK RAILS TO BOW DECK AND WHEELHOUSE DECK IN ACCORDANCE WITH 46 CFR 177.35-1. NO PASSENGERS SHALL BE ALLOWED FWD OF DECKHOUSE UNTIL SUCH TIME RAILS ARE INTALLED.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 27 February 1991 Resolved
REMOVE EXISTING GENERATOR EXHAUST PIPING (PVC) AND INSTALL APPROVED MATERIAL
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Engineering
Issued 27 February 1991 Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM. SUCH WARNING SHALL BE VISIBLE OR AUDIBLE AT THEENGINE OPERATING STATION._x001C_ _x001C_
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Accommodation/Occupational Safety
Issued 27 February 1991 Resolved
INSTALL RAILING ON SECOND DECK AFT OF PILOTHOUSE
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
REMOVE ALL SOLDERED ELECTRICAL CONNECTIONS AND INSTALL APPROVED ELECTRICAL CONNECTORS_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Fire Fighting
Issued 27 February 1991 Resolved
INSTALL PROPER BRACKET FOR HALON CYLINDER IN ENGINEROOM
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Construction/Loadline
Issued 27 February 1991 Resolved
INSTALL DOUBLE BASE CLAMPS FOR ALL SEA SUCTION HOSES.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Engineering
Issued 27 February 1991 Resolved
RE-ATTACH FUEL FILTER TO PORT MAIN ENGINE TO BACKING BOARD_x001C_
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Construction/Loadline
Issued 27 February 1991 Resolved
INSTALL PIPE PLUG TO .75" GATE VALVE THROUGH HULL FITTINGS.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
INSTALL COVER TO BATTERY BOX INSTALLATION FOR GENERATOR.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
PROPERLY SECURE WIRE TO PORT MAIN ENGINE ALTERNATOR
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
PROPERLY SECURE SHUNT ON PORT MAIN ENGINE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
INSTALL BLANK COVERS TO ELECTRICAL DISTRIBUTION PANEL IN ENGINEROOM WHERE CIRCUT BREAKERS ARE MISSING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991

Casualty record · 1

4 August 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7525540
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.