Records from 1996 to 2006. Most recent: inspection, 29 March 2006.
Inspection history · 23
29 March 2006
MARPOL Annex V Examination · ISPS I Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2611735
29 March 2006
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2612023
20 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2605629
17 March 2006
NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2604458
4 March 2006
In-Service Inspection · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2595899
19 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1732761
19 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734524
2 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 121165
3 August 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 19708
19 November 1999
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393284
16 November 1999
Uninspected Towing Vessel
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 810850
15 November 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 12970
14 August 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 187667
2 May 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 88795
17 February 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 93159
30 November 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 44884
26 August 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 188892
2 July 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 143144
11 February 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 79409
5 January 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 136723
2 November 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 94886
21 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 166645
7 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 36542
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 March 2006
Resolved
Remove excess combustables from engine room. Obtain proper trash receptacles, with metal lids. To satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2006
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 29 March 2006
Resolved
Prove proper functioning of flame detector units in engine room. Provide for servicing facilty to inspect. To satisfaction of class.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2006
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 29 March 2006
Resolved
Repair holes/wasted paint locker bulkhead. To satisfaction of class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2006
Accommodation/Occupational Safety › Messroom › Size
Issued 29 March 2006
Resolved
Remove/restow food items located in towing winch room. To sattisfaction of attending CG inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 March 2006
Resolved
Provide for approval of vessels fire control plan. Mount plans in watertight containers and bulkhead as required by SOLAS regs. To satisfaction of vsls class.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 March 2006
Resolved
Reinstall missing deck grating on vessels bow. To sattisfaction of vessels class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2006
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 29 March 2006
Resolved
Repai softpatched piping IWO cooling water for packing gland main shaft. To statsifaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2006
Engineering
Issued 19 November 1999
Resolved
PROVIDE STATEMENT FROM CLASS ATTESTING TO THE NATURE OF THE TUG APRIL MORAN'S CONTROLLABLE PITCH PROPELLOR SYSTEM CASUALTY, REPAIR RECOMMENDATIONS, AND VESSEL'S ABILITY TO PERFROM TOWING AND PUSHING OPERATIONS.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Documentation
Issued 16 November 1999
Resolved
PROVE COMPLIANCE WITH USCG/DOT DRUG TESTING COMPLIANCE.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Lifesaving
Issued 16 November 1999
Resolved
RENEW RETRO ON RING BUOY
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999