Records from 1989 to 2013. Most recent: casualty investigation, 19 June 2013.
Documentation record
Registered dimensions (L × B × D)42.5 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 13 / net 8
ITC dimensions (L × B × D)42.5 ft × 20.0 ft × 6.0 ft
ITC tonnageNot recorded
BuilderU S STEEL SHIPYARD INC · LAROSE, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
23 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330891
17 January 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130832
20 May 2004
Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2072754
20 February 2003
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1746858
7 January 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1726900
3 January 2002
COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1475053
9 March 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046986
12 October 1999
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434940
18 March 1999
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410070
22 December 1997
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416568
24 December 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458360
16 November 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431576
21 December 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 856698
18 October 1994
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359956
8 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174088
29 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666528
23 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49842
7 October 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1366915
23 November 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 827198
13 October 1992
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930716
8 October 1992
Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264758
17 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415766
18 August 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267352
3 August 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254372
2 July 1992
Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951433
24 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 7347
21 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251548
17 October 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935770
8 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901197
15 November 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925668
1 November 1990
Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918964
1 November 1989
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928951
Electrical › Electrical Distribution System (service)
Issued 7 January 2003
Resolved
Properly label electrical distribution panel and blank opening in the panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 7 February 2003
Resolved 20 February 2003
Engineering
Issued 7 January 2003
Resolved
Prove perssure/temp valve on the hotwater heater.
Due 7 February 2003
Resolved 20 February 2003
Lifesaving › Buoyant Apparatus
Issued 7 January 2003
Resolved
Prove life float is Coast Guard approved.
Due 7 February 2003
Resolved 7 January 2003
Deck/Cargo
Issued 7 January 2003
Resolved
Prove crane certification.
Due 7 February 2003
Resolved 20 February 2003
Construction/Loadline
Issued 12 October 1999
Resolved
C/R WASTED DECK P/S AFT.
Condition: Unknown
Due 12 November 1999
Resolved 15 October 1999
Construction/Loadline
Issued 12 October 1999
Resolved
C/R WASTED DECK STB SIDE BOW.
Condition: Unknown
Due 13 November 1999
Resolved 15 October 1999
Engineering
Issued 12 October 1999
Resolved
LABEL SHUT OFF DIRECTION AT EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 12 November 1999
Resolved 15 October 1999
Construction/Loadline
Issued 12 October 1999
Resolved
G/W INSERT P/S AFT ENG ROOM.
Condition: Unknown
Due 12 November 1999
Resolved 15 October 1999
Construction/Loadline
Issued 12 October 1999
Resolved
REPAINT NAME ON VESSEL.
Condition: Unknown
Due 13 November 1999
Resolved 15 October 1999
Lifesaving
Issued 12 October 1999
Resolved
PROVIDE NEW HYDROSTATIC RELEASE FOR EPIRB. VESSEL RESTRICTED TO 03 MILES FROM SHORE UNTIL ITEM CORRECTED.
Condition: Unknown
Due 13 November 1999
Resolved 15 October 1999
Lifesaving
Issued 22 December 1997
Resolved
COMPLETE AND LOG TRAINING AS REQUIRED BY 46CFR185.
Condition: Unknown
Due 22 January 1998
Resolved 24 April 1998
Engineering
Issued 18 October 1994
Resolved
REPLACE STRUT BEARING (OUTER SHAFT BEARING) ON PORT PROPULSION SHAFT.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Documentation
Issued 13 October 1992
Resolved
PROVIDE A COPY OF COMPUTED STABILITY CALCULATIONS TO THE MARINE SAFETY CENTER FOR REVIEW AND APPROVAL. A INFO COPY SHALL BE PROVIDED TO OCMI _x001C_ NEW ORLEANS._x001C_ _x001C_
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Engineering
Issued 2 July 1992
Resolved
REPAIR/REPLACE PORT MAIN ENGINE LOW WATER [MURPHY] GAUGE ALARM.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Engineering
Issued 2 July 1992
Resolved
REPLACE WASTED FUEL TANK FILL (NEOPRENE) COUPLING.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Construction/Loadline
Issued 2 July 1992
Resolved
MAKE WATERTIGHT REPAIRS TO HOLE IN PORT SIDE BOW.
Condition: Unknown
Due 5 July 1992
Resolved 5 July 1992
Electrical
Issued 2 July 1992
Resolved
REPAIR/REPLACE ALL INOPERATIVE ENGINE ROOM LIGHTS (SIX (6) TOTAL)
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Engineering
Issued 2 July 1992
Resolved
PROVIDE PROTECTIVE GUARDS FOR BOTH PORT AND STBD ROTATING MACHINERY ON MAINENGINES
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Documentation
Issued 1 November 1989
Resolved
PROVIDE A COMPLETE OPERATING MANUAL IN ACCORDANCE WITH 46 CFR 109.121 FOR REVIEW TO MSO NEW ORLEANS TO FORWARD TO COMMANDANT (G-MSC).
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Electrical
Issued 1 November 1989
Resolved
LABEL BREAKERS IN MACHINERY SPACE BREAKER BOXES, INCLUDING MAIN GENERATOR BREAKER AND PROVIDE A HANDLE FOR MAIN GENERATOR BREAKER.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Documentation
Issued 1 November 1989
Resolved
PROVIDE FOR REVIEW THE FOLLOWING PLANS TO MSO NEW ORLEANS TO FORWARD TO COMMANDANT (G-MSC): GENERAL ARRANGEMENTS, INBOARD AND OUTBOARD PROFILES, STABILITY CALCULATIONS, LEG STRUCTURES, JACKING TOWER STRUCTURES, HYDRAULICSYSTEMS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 1 November 1989
Resolved
GAUGE BOTTOM PLATING IN WAY OF FORWARD AND AFT TRANSVERSE BULKHEADS AND PROVIDE REPORT OF EXAMINATION. PROPOSE PERMANENT REPAIRS TO ANY PLATING MORE THAN 25% WASTED FROM ORIGINAL THICKNESS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Fire Fighting
Issued 1 November 1989
Resolved
PROVIDE A PERMANENT "HARD PIPED" INSTALLATION FOR FIREPUMP SUCTION, INCLUDING A STRAINER AND FOOT-VALVE. THIS INSTALLATION MUST ALSO ALLOW FIREPUMP SUCTION TO BE TAKEN FROM A SUCTION HOSE WHILE IN THE JACKED-UP CONDITION.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Engineering
Issued 1 November 1989
Resolved
REMOVE ALL WOODEN DECK PLATES FROM MACHINERY SPACE.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Engineering
Issued 1 November 1989
Resolved
CLEAN ALL BILGES OF OIL.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 1 November 1989
Resolved
REPLACE GASKETS ON ALL MANHOLE COVERS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Lifesaving
Issued 1 November 1989
Resolved
PROVIDE AN USCG-APPROVED WEAK-LINK FOR LIFEFLOAT.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Navigation
Issued 1 November 1989
Resolved
PROVIDE A SOUND-PRODUCING BELL AS REQUIRED BY THE COLREGS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Engineering
Issued 1 November 1989
Resolved
PROVIDE A 30 X 30 WIRE MESH FLAME SCREEN FOR THE FUEL OIL TANK VENT.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Lifesaving
Issued 1 November 1989
Resolved
PROVIDE AN APPROVED RESCUE BOAT OR DEMONSTRATE AN ALTERNATIVE THAT IS ACACEPTABLE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Lifesaving
Issued 1 November 1989
Resolved
PROVIDE AN INSTANTLY-ACCESSIBLE MEANS OF EMERGENCY ESCAPE FOR THE CREW WHILE IN A JACKED-UP CONDITION.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 1 November 1989
Resolved
PROVIDE AND DEMONSTRATE A "DEAD MAN" STOPPING FEATURE TO THE JACKING GEAR CONTROLS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989