Records from 2001 to 2026. Most recent: inspection, 3 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 21
3 June 2026
Drydock Exam · Vessel Attendance · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8391415
19 August 2025
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8214669
17 June 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8137876
3 June 2024
COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7888342
4 March 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7872950
23 September 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7799658
8 June 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7709828
8 November 2022
Damage Survey · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7594413
6 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7469594
17 May 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7452480
28 July 2021
DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7283727
18 July 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7276696
22 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7232284
27 May 2020
Administrative Inspection · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6965779
19 June 2019
Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6719207
31 March 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6659348
18 May 2018
Drydock Exam · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6418067
1 August 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6229711
21 June 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6017154
10 May 2016
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913808
7 March 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5833230
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 11 June 2026
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI... Attending marine inspector observed repairs made to both aluminum conduits/ support structures identified in Deficiency # 7 of this inspection without proper approval. The outboard portion (from 2 o'clock to 6 o'clock when observed from the forward entry to the tank space on the port side unit) of the weld presents with porosity and signs of corrosion on the base material. Remove suspect portion of the weld to expose base material for further evaluation of repairs as made.
46 CFR 176.610(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2026
Resolution: Item cleared by DBC following atendance and reevaluation of structural relevance.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 June 2026
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Stbd quarter rail station separated from base. Repair in accordance with procedure used to correct the 02 other separated stantions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2026
Resolution: Attending marine inspector observed 02/03 restored via approved repair proposal while attending. Operator provided photgraphs after departure of 3rd stantion repaired in the same manner.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 June 2026
No resolution recorded
Branch circuit conductors for hot water supply boilers which have a capacity not greater than 454 liters (120 U.S. gallons) must have a current carrying capacity of not less than 125 percent of the current rating of the appliance. No appropriate overcurrent protection installed for water heater. Install appropriate over-current protection IAW email correspondence dtd. 08 May 2026.
46 CFR 63.25-3(c)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026 — due date passed with no resolution recorded
Resolution: 06/25/25 - Extended, see general information.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2026
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Battery charger lacks overcurrent protection as required per manufacturer specification. Install appropriate over-current protection IAW email correspondence dtd. 08 May 2026.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 25 June 2026
Resolution: Appropriate over current protection installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2026
Resolved
Each circuit breaker must meet UL 489 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant, and be of the manually reset type... Multiple breakers in the white housing on forward engineroom bulkhead and on stbd bulkhead of teh ladder well to heads not labeled as UL compliant. Install appropriate over-current protection IAW email correspondence dtd. 08 May 2026.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 25 June 2026
Resolution: Appropriate over current protection installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2026
No resolution recorded
ll cable and wire must... Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Wiring throughout fuel tank compartment supported by zip-ties. Replace with approved securing devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 June 2026
Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body... Damage identified on stbd sheerstrake and stbd quarter under exhaust discharge. Expose to good material and provide repair proposal to the satisfaction of the attending marine inspector prior to credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 June 2026
Resolution: Restored to attending marine inspectors satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 June 2025
Resolved
Each item of lifesaving equipment determined by the Marine Inspector to not be in a serviceable condition must be repaired or replaced. Vessel's owner informed Marine Inspector that both lifefloats were not in serviceable condition from lack of maintenance. The attending Marine inspector(s) confirmed that the lifefloats were deteriorated beyond the point of serviceability and that float free arrangements were not maintained to function as designed. Vessel Owner has requested to limit the vessels route on Certificate of Inspection due to being in compliance with §180.205(e)(3); having on board a FCC Type Accepted Category 1 406 MHz EPIRB installed to automatically float free and activate. Effective immediately, the vessel may not operate in waters beyond 3NM from land. (1) Provide written request to OCMI to remove lifeloats from vessel or (2) Repair/replace lifefloats and float free arrangements to the satisfaction by the attending Marine Inspector.
46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 29 June 2025
Resolution: Vessel submitted a request to remove lifefloats and it was granted.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 June 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Starboard forward bulkhead in engine space contained an opening that compromised vapor tight requirement. Fill/plug opening to the satisfaction of the attending Marine Inspector.
46 CFR 177.405(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 29 June 2025
Resolution: Vessel plugged opening to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2025
Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Vessel did not provide documentary evidence that crew and supervisory personnel received required training. Provide a written record of crew and supervisory training conducted for vessel personnel to the satisfaction of the attending Marine Inspector.
46 CFR 16.401(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2025
Resolved 29 June 2025
Resolution: Vessel provided evidence of crew and supervisory training.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2024
Resolved
Each ring life buoy on a vessel must: (1) be approved un accordance with 46 cfr 160.050 in subchapter Q of this chapter... Ring life buoy has numerous tears and grab line was dry rotted.
46CFR180.70 (b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 23 June 2024
Resolution: O/O sent in satisfactory evidence of new ring life buoy. (Photo)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2024
Resolved
Remote fuel shutoffs stations must be marked in clearly legible letters... Fuel shutoffs markings were faded away.
46CFR185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 23 June 2024
Resolution: O/O sent in satisfactory evidence of new markings of fuel shutoffs. (Photo)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2024
Resolved
The area of operation for each vessel and any necessary operational limits are determined by the cognizant OCMI, and recorded on the vessel's Certificate of Inspection. The vessel's ownership has recently changed resulting in the vessel moving from Maui to Oahu to conduct commercial passenger operations. Appropriate documentation has been applied for to reflect the ownership change; however, NVDC has not processed yet. The vessel's new route is:
PACIFIC OCEAN, STATE OF HAWAII, SOUTHERN AND WESTERN COASTS OF THE ISLAND OF OAHU BETWEEN A LINE EXTENDING SOUTH BY SOUTHWEST FROM KOKO HEAD TO A LINE EXTENDING SOUTHWEST FROM KAENA POINT, NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
All other conditions of operation listed on the COI remain applicable and in effect. COI will be amended upon owner's receipt of updated COD.
46 CFR 176.110(a)
Action required: 705 - Other - as specified
Resolved 17 June 2024
Resolution: Vessel completed COI Inspection and has route change documented on new COI.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 November 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. Starboard side hull mid ship suffered damage approximately 24 x 4 inches in size above the water line. Vessel allided with pier. Make permanent FRP repairs in accordance with NVIC 8-87 prior to taking passengers.
46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2022
Resolution: Perm repairs made. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2022
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed mush have the following equipment at the operating station: A means to reset devices used to automatically shutdown ventilation systems and engines as required by paragraph (a)(3) of this section. The Fire boy override was inoperative during testing.
46CFR181.420(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2022
Resolution: Replaced Fireboy controller.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 June 2022
Resolved
The painter must: Have breaking strength of at least 1,500 pounds. The painter line for the life float was wasted.
46CFR180.175(3)(ii)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2022
Resolution: Replaced painter line.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 June 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of Large enough scale to make safe navigation possible. Chart on board where not up-to-date.
46CFR184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 22 June 2022
Resolution: New charts provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2022
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy is worn. Replace life ring buoy.
46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 22 June 2022
Resolution: New ring buoy provided.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 June 2022
Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are less than 4 feet and are not lashed to the life floats. Provide the appropriate number of paddles properly arranged to life floats on board vessel.
46 CFR 180.175
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 22 June 2022
Resolution: Paddles lashed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 July 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 9 August 2021
Resolution: DER provided proof of training completed for all required personnel.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 22 June 2021
Resolved
01 bilge high level visual alarm indicator not operational. Visual and audible indicator must be provided at operating station. Provide operational visual alarm indicator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: Indicator operational.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 22 June 2021
Resolved
01 automatic bilge pump indicator not operational. Visual indicator must be provided at the operating station for any automatic bilge pump when operating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 23 June 2021
Resolution: Indicator operational.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 June 2021
Resolved
Life float light housing cracked. Provide new floating water light for life float.
Prior to nighttime operations.
Action required: 705 - Other - as specified
Resolved 23 June 2021
Resolution: New light provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2021
Resolved
Ring buoy floating water light not operational. Make ring buoy floating water light operational.
Prior to nighttime operations.
Action required: 705 - Other - as specified
Resolved 23 June 2021
Resolution: Water light operational.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 June 2021
Resolved
Navigation publications not on vessel. Provide navigation publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 23 June 2021
Resolution: Nav pubs provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 June 2019
Resolved
Engine compartment Fireboy audible alarm did not sound when tested. Prove correct operation in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Audible alarm satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 June 2019
Resolved
Lifefloat arrangement was unsatisfactory. Lifefloats utilized single painter and were not chained together. Painter was made to grab line of single lifefloat. Painter was detriorated. Prove correct lifefloat arrangement in accordance with 46 CFR 180.137.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Painter renewed. Floats properly chained together. Painter fixed around body of float.