Records from 2000 to 2007. Most recent: operational control imposed, 19 May 2007.
Inspection history · 23
19 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2934371
3 May 2007
COC-CHEM Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2921587
7 April 2006
Ballast Water Examination · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2613515
29 July 2005
COC-CHEM Annual · ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2443803
14 April 2005
Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2329639
14 April 2005
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2329641
16 February 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2293731
17 November 2004
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2243358
8 July 2004
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2125786
4 June 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2088393
26 March 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2032013
21 August 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1882734
19 August 2003
Certificate of Compliance · Deficiency Check · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1881683
7 June 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1812316
27 December 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1723458
21 November 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1708969
30 August 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1668812
28 June 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1638534
28 May 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 65759
16 May 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290125
10 May 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 106147
2 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275473
2 March 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815892
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 May 2007
No resolution recorded
Multiple A-class fire doors have hold backs and are not self closing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 June 2007 — due date passed with no resolution recorded
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 July 2004
Resolved
Two out of the four fireman outfits have holes and the fire retardent material is peeling off.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 17 November 2004
Resolution: were replaced
Lifesaving › Launching Appliances › Davit
Issued 8 July 2004
Resolved
Vessel's port lifeboat davit aft inner and fwd inner pulley wheels were seized during the lowering and raising of the lifeboat from the embarkation deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 17 November 2004
Resolution: Recieved class report
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 July 2004
Resolved
The 2/O, 3/O, 2/E, and 3/E could not provide an appropriate certificate or endorsement of an existing certificate from the flag state for their national chemical tanker license.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 13 July 2004
Resolution: Recieved proof of application from Flag State for all four crew members.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 8 July 2004
Resolved
All vessels's (8) vapor control lines have a screw-type attached stud at the top of the vapor connection flange.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2004
Resolved 17 November 2004
Resolution: Recieved class report
Personnel › Certificates/Documents/Licenses
Issued 19 August 2003
Resolved
Vessel 2nd engineer did not have a valid Italian STCW endorsement. STCW 95 Reg. I/2 (5). LEGACY COMPONENT DESC: License, Assistant Engineer
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2003
Resolution: Recieved an Italian endorsement from the Italian consulate in Napoli Italy.
Deck/Cargo › Inert Gas System
Issued 19 August 2003
Resolved
Vessel IGS could not produce below 5% oxygen as per SOLAS 74 ammended Chapter II-2 reg. 62.3.2. Vessel does have N2 plant.
Action required: 15 - Rectify deficiencies by next port
Resolved 19 August 2003
Resolution: Cleared prior to leaving vessel.
Deck/Cargo › Inert Gas System
Issued 19 August 2003
Resolved
Vessel to provide span gas in accordance with oxygen analyzer operation manual as per SOLAS 74 ammended Chapter II-2 Reg. 62.
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 26 March 2004
Resolution: CLASS REPORT RECIEVED
Engineering › Fuel Oil Service System
Issued 19 August 2003
Resolved
Main engine high pressure fuel lines are not jacketed and do not have fuel line failure alarms as per SOLAS 74 ammended Chapter II-2 Reg. 15.2.12. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 26 March 2004
Resolution: CLASS REPORT RECIEVED
Fire Fighting › Firemans Outfit
Issued 28 June 2002
Resolved
Two SCBA units are not functioning properly and several other SCBA's and the spare bottles are in poor condition. Provide servicing report for all SCBA's and spare bottles. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 3 July 2002
Resolution: Received invoice for 4 new SCBA''s. Received service report for remain SCBA''s and spare bottles.
Electrical › Lighting (service)
Issued 28 June 2002
Resolved
Several cargo deck lighting fixtures are corroded, not gas tight and filled with water. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 30 August 2002
Resolution: Six (6) deck lights renewed with CEAG explosion protected light fixtures via fax from RINA.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 28 June 2002
Resolved
The emergency shutdown button located at the starboard manifold does not work. LEGACY COMPONENT DESC: Emergency Shut-down
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 30 August 2002
Resolution: Emergency shutdown at starboard manifold tested and found satisfactory via class fax from RINA.
Documentation › Logs/Records
Issued 28 June 2002
Resolved
Vessel could not provide documentary proof of flag/class attestation that the vessel meets the U.S. double hull design standards of 33 CFR 157.10d. Analysis of ships plans was carried out and vessel appears to meet the requirements.
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 30 August 2002
Resolution: Reference Class attestation that vessel meets the U.S. double hull design standards of 33 CFR 157.10(d) via fax from RINA.
Pollution Prevention/Response › Response Equipment
Issued 28 June 2002
Resolved
Vessel does not have the required spill equipment.
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 3 July 2002
Resolution: Received invoice for required spill equipment.
Deck/Cargo › Inert Gas System
Issued 28 June 2002
Resolved
Vessel's Inert Gas System is inoperative. Vessel prohibited from using IGS or carrying cargoes that require IGS in U.S. water until repaired to the satisfaction of class and demonstrated to U.S. Coast Guard.
Action required: 705 - Other - as specified
Due 12 July 2002
Resolved 30 August 2002
Resolution: Inert Gas System tested and found satisfactory. Blower 1 new motor installed. Blower 2 ashore to be rewound via fax from RINA.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 June 2002
Resolved
The M/E's No. 1 and 2 cylinder pushrod seals are leaking.
Action required: 705 - Other - as specified
Due 12 July 2002
Resolved 30 August 2002
Resolution: Main Engine Rod seals repaired and found satisfactory via fax from RINA.