Records from 1994 to 2025. Most recent: inspection, 25 August 2025.
Inspection history · 51
25 August 2025
Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8217509
10 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8061033
12 December 2024
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8042887
22 February 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7861313
13 February 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7624468
3 January 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7591308
18 February 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7389632
8 December 2020
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7093395
23 November 2020
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7093380
5 March 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6917042
24 June 2019
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6704504
27 February 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6625334
5 September 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6586853
14 November 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6306397
10 February 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6085921
6 December 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033198
9 December 2015
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5778045
12 December 2011
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4206281
30 November 2010
Administrative Inspection · Internal Structural Exam · Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3883382
9 February 2010
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3677309
24 February 2009
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3427550
2 December 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3372029
25 February 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3152872
26 February 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2878410
5 December 2005
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2543430
26 June 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2480029
18 January 2005
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2277460
2 December 2004
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2246204
28 September 2004
In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2207391
6 May 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2060619
17 February 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2004757
31 January 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1736286
5 December 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1717344
16 April 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1605652
4 February 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1482585
17 April 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048497
16 April 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 25562
11 January 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1462803
28 October 1998
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468913
8 December 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1450118
5 August 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 5448
11 December 1996
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1374863
30 October 1996
Drydock Extension · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1368038
3 June 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1086311
23 February 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080567
28 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879735
22 December 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150108
30 November 1994
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 869423
20 October 1994
Plan Review "T" Boat · Inclining Experiment · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181477
10 August 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866382
9 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 870174
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2020
Resolved
The preventative maintenance plan (PMP) should address the following at a minimum: the maintenance schedule of the rigging and associated equipment to include detailed protocol for examinations and inventory of rigging components including age of component as well as size and replacement schedule. The vessel's PMP does not contain the age of components or replacement schedules. The vessel's PMP is missing detailed protocol for examinations to be conducted by the crew. The vessel's PMP is missing the crew's initials for maintenance during the months of June, July, August, September and October. Identified the following during a visual inspection of the deck level standing rigging: port side main mast lower aft shroud found with a wasted cotter pin used to retain the turnbuckle toggle pin, the same condition was found at the mizzen mast port side and starboard side lower aft shrouds. Identified what appeared to be a corroded backing plate under the head stay chainplate located at the stem. The operator shall remove the head stay chainplate at the next scheduled dry dock for further inspection. The operator shall contract a third party surveyor to complete a rigging inspection to include a rigging inspection aloft. The rigging inspection shall establish a baseline to update the vessel's PMP. The updated PMP shall include at a minimum: the maintenance schedule of the rigging and associated equipment to include detailed protocol for examinations and inventory of rigging components including age of component as well as size and replacement schedule (life cycle). A third party rigging survey does not substitute for the vessel owner/operator from implementing a PMP or conducting/documenting preventative maintenance. 46 CFR 176.840
Action required: 705 - Other - as specified
Due 23 January 2021
Resolved 3 February 2021
Resolution: A new PMP created by company follows the guidelines of NVIC 02-16. A third party completed a rigging survey to include a survey aloft. Rigging found to be unsat was replaced in kind during the credit dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 November 2020
Resolved
Diesel engine cooling systems shall be in accordance with 46 CFR 182.20-10. The aux diesel generator was found with a leaking water cooling system. Repair or replace necessary piping or pumps to ensure the cooling system is operational and no longer leaking. 46 CFR 182.20-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 14 January 2021
Resolution: The aux generator water pump and piping were replaced in kind. The aux generator was operationally tested and found in satisfactory condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 November 2020
Resolved
All vessels shall be provided with bilge pumps in accordance with 46 CFR 182.25-10(a). Bilge pumps shall be tested at each COI in accordance with 46 CFR 176.804(h). The through hull for bilge pumps is under the water line and cannot be verified when the vessel is in the water. Prove operation of bilge pumps at dry dock. 46 CFR 176.804(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 8 December 2020
Resolution: The bilge pump was operationally tested and effluent was discharged on the port side.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2020
Resolved
Remove headstay chain plate located at vessel stem for visual inspection of backing plate. Remove at next scheduled dry dock. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 8 December 2020
Resolution: The head stay chain plate was removed for inspection. The backing plate was replaced in kind. The chain plate fasteners were replaced in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 November 2020
Resolved
A lifejacket shall be on board for each person to include passengers and crew. 10 lifejackets were found in need of retroreflective material. Renew retro reflective material and place life jackets back into service. Total passenger count reduced to 18. 46 CFR 185.604 (h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 14 January 2021
Resolution: The operator renewed retro reflective tape on 10 lifejackets and placed them back into service. Visually inspected all lifejackets with no deficiencies noted.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 November 2020
Resolved
EPIRB found located in the operator cockpit under a canopy. This prevents the EPIRB from a float free arrangement. Install the EPIRB in a location that permits a float free arrangement. 46 CFR 180.64
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 14 January 2021
Resolution: The EPIRB was removed from the cockpit and found mounted to the port stern railing where it is no longer obstructed by the overhead canopy.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 December 2015
Resolved
Install belt guard over rotating machinery on front of Main Diesel Engine. 46 CFR 177.960
Due 25 December 2015
Resolved 23 December 2015
Resolution: Installed
Construction/Loadline › Structures › Superstructure
Issued 12 December 2011
Resolved
Prior to or during next dry-dock exam, step Main and Mizzen mast for inspection. INSP NOTE 13
Action required: 705 - Other - as specified
Resolved 25 June 2013
Resolution: Main and Mizzen were stepped in the presence of rigger and marine inspector, SAT.
Navigation › Piloting/Steering › Marine Charts
Issued 30 November 2010
Resolved
Provide updated/corrected nautical chart. Vessel's charts are out of date.
Due 17 December 2010
Resolved 21 December 2010
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 November 2010
Resolved
Label cabin on deck that contains "pull cable" for the fixed fire extinguishing apparatus. It must be labled in clearly legible letters "Fire extinguishing apparatus".
Due 17 December 2010
Resolved 17 December 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 November 2010
Resolved
Labeling on cabinet containing lifejackets is not legible. Label cabinet, "child lifejackets".
Due 17 December 2010
Resolved 17 December 2010
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 December 2005
Resolved
Repair hole/crack and replace retro-reflective tape as discussed. LF skin had been punctured from the mounting stand. LF is in good condition and can be patched with [name withheld] repair kit. Some of the retro was pulled back from the same mounting bracket. Discussed means of protecting LF in the future.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 December 2005
Resolution: POC HAS CHANGED OUT LF WITH AN EPIRB.
Lifesaving › Hand Flares › Storage
Issued 5 December 2005
Resolved
Provide a water tight container for flares and label, IAW 46CFR185.614. Container was a pleasure craft flare container which is not water tight. POC has a water tight container at his home and will bring it in the morning.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 13 December 2005
Resolution: POC PURCHASED A NEW CONTAINER FOR FLARES.
Communications › Radio Communications › EPIRB
Issued 5 December 2005
Resolved
Provide an up-dated FCC Safety and Station license with EPIRB information. O/O is replacing his 08 person LF with an EPIRB.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 December 2005
Resolved 13 December 2005
Resolution: PROVIDED EPIRB REGISTRATION.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 January 2005
Resolved
Provide new batteries for waterlight on lifefloat.
Due 28 February 2005
Resolved 30 January 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 January 2005
Resolved
Renew lanyard on lifelfoat per 46 CFR 180.175(f)(4).
Due 28 February 2005
Resolved 18 January 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 January 2005
Resolved
Provide two additional adult life jackets for a total of 36, prior to carrying more than 34 adult passengers and crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Communications › Radio Communications
Issued 17 February 2004
Resolved
ENTERED IN ERROR - NO DEFICIENCY.
Due 17 February 2004
Resolved 17 February 2004
Resolution: ENTERED IN ERROR.
Lifesaving › Lifebuoys
Issued 17 February 2004
Resolved
ENTERED IN ERROR - NO DEFICIENCY. LEGACY COMPONENT DESC: Waterlight
Due 17 February 2004
Resolved 17 February 2004
Operations/Management › Drug and Alcohol Testing
Issued 31 January 2003
Resolved
PROVIDE PROOF OF CURRENT CHEMICAL TESTING PROGRAM TO INCLUDE PRE-EMPLOYMENT TESTING, RANDOM TESTING, SERIOUS MARINE INCIDENT TESTING, REASONABLE CAUSE TESTING, AND EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 14 February 2003
Resolved 17 February 2004
Resolution: CONSORTIUM = APCA.
Construction/Loadline › Structures
Issued 5 December 2002
Resolved
REPLACE CRACKED PORT AFT CHAIN PLATE. LEGACY COMPONENT DESC: Chain Plate
Condition: Unknown
Due 31 January 2003
Resolved 30 January 2003
Resolution: REPLACED.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 4 February 2002
Resolved
INSTALL SHUTDOWN ON GENSET INTEGRAL WITH FIXED FIRE SYSTEM. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 16 April 2002
Resolution: TESTED SHUT DOWN - SAT.
Fire Fighting
Issued 8 December 1997
Resolved
INSTALL FIXED SYSTEM WITH ADEQUATE CAPACITY FOR SPACE PROTECTED.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 11 December 1996
Resolved
SERVICE HALON SYSTEM.
Condition: Unknown
Due 12 February 1997
Resolved 12 February 1997
Lifesaving
Issued 11 December 1996
Resolved
INSTALL RETRO MATERIAL ON LIFE RING.
Condition: Unknown
Due 12 February 1997
Resolved 12 February 1997
Accommodation/Occupational Safety
Issued 23 February 1996
Resolved
PROVIDE LOCKING DEVICE ON MSD OVERBOARD VALVES TO LOCK IN THE CLOSED POSITION.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Lifesaving
Issued 23 February 1996
Resolved
PROVIDE ON DECK STOWAGE OF PFD IN A FLOAT FREE LOCATION.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996