MAURY USCG vessel records Sign in
← All vessels

P'TI BLEU II

P'TI BLEU II is a 1982 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1985, most recently in February 2002, along with 84 deficiencies — 11 with no resolution recorded —.

Records from 1985 to 2002. Most recent: inspection, 21 February 2002.

Built
1982
Last inspected
21 February 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

205275
Flag
UNITED STATES
—
Maury page id
psix-205275

Inspections, by type

…with no type recorded16
…past their stated due date11
Years with a record 18 calendar years (1985–2002)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCP2039MMSI not assigned · expired · compulsorily equipped · granted 1 December 1994, cancelled 5 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

21 February 2002 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1611593
29 October 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 754837
20 August 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 32129
20 August 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 207626
6 June 2001 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1362437
1 April 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 224494
13 March 2001 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1451677
16 April 2000 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 220865
25 February 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1412058
10 June 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 809229
22 February 1999 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1411817
9 November 1998 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1418425
6 November 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472439
31 October 1997 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368484
24 October 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 755133
12 October 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 196662
12 October 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 224899
9 May 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1092585
17 April 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 774268
10 February 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1091670
8 October 1996 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367935
2 November 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1192501
30 October 1995 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360304
25 April 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 863976
1 April 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1145021
25 January 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1136165
31 October 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1389909
6 October 1994 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359971
11 July 1994 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 866545
8 November 1993 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 362999
8 November 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1465768
23 September 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 840840
14 June 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1149851
5 February 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1137933
16 November 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395937
31 July 1992 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1258635
19 November 1991 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1247177
19 December 1990 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 919505
19 November 1990 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211619
3 August 1990 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 918920
24 May 1990 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 911869
27 November 1989 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 921694
24 May 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 896656
28 November 1988 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1206602
21 December 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1005367
21 October 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1017991
8 August 1987 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1030214
2 June 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1336173
1 December 1986 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1007212
1 December 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315473
1 December 1986 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315475
1 December 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315476
26 February 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 978130

Deficiency record · 84

Construction/Loadline › Structures › Deck Plating
Issued 21 February 2002 No resolution recorded
REMOVE WOOD PLANKS FROM CAR DECK. MECHANICALLY PREPARE SURFACE AND AUDIOGAUGE STEEL PLATING
Due 21 February 2002 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 21 February 2002 No resolution recorded
RENEW WASTED METAL IN FWD CARGO DECK AREA AND PORT DECK VOID AREA.
Due 21 February 2002 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 21 February 2002 No resolution recorded
RENEW BOTH ENGINE ROOM DOORS
Due 21 February 2002 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 21 February 2002 No resolution recorded
MECHANICALLY PREPARE AFT DECK ABOVE STEERING ROOM AND RENEW WASTED METAL.
Due 21 February 2002 — due date passed with no resolution recorded
Communications › Radio Communications › VHF Radiotelephone
Issued 21 February 2002 No resolution recorded
RENEW BROKEN VHF ANTENNEA
Due 21 February 2002 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 21 February 2002 No resolution recorded
REMOVE OILY BILGE WASTE FROM ENGINE ROOM
Due 21 February 2002 — due date passed with no resolution recorded
Fire Fighting › Fire Pumps › Arrangement
Issued 21 February 2002 No resolution recorded
REPAIR PORT ENGINE BILGE/FIRE PUMP
Due 21 February 2002 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2002 No resolution recorded
REMOVE BILGE PUMP WIRING FROM ENGINE ROOM
Due 21 February 2002 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 21 February 2002 No resolution recorded
RENEW ALL WASTED METAL ON INBOARD SIDE SHELL PLATING
Due 21 February 2002 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 February 2002 No resolution recorded
VESSEL MUST COMPLETE AN INSPECTION FOR CERTIFICATION PRIOR TO RETURNING TO SERVICE
Due 21 February 2002 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 February 2002 No resolution recorded
VESSEL MUST BE DRYDOCKED PRIOR TO RETURNING TO SERVICE
Due 21 February 2002 — due date passed with no resolution recorded
Lifesaving
Issued 6 June 2001 Resolved
REPAIR/RENEW ALL LIFEJACKETS AS IDENTIFIED BY THE CG INSPECTOR.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
INSTALL NEW PAINTERS FOR BOTH LIFEFLOATS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
PERMANENTLY ATTACH WATERLIGHTS TO EACH LIFEFLOAT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Navigation
Issued 6 June 2001 Resolved
PROVIDE OPERATIONAL COMPASS LIGHT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
PROVIDE AND SECURE PADDLES IN BOTH LIFEFLOATS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 6 June 2001 Resolved
PROVIDE RADIO OPERATORS PERMIT FOR JAMES U. BOYNES
Condition: Unknown
Due 7 October 2004
Resolved 7 October 2004
Resolution: 07OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Documentation
Issued 6 June 2001 Resolved
PROVIDE CPR CERTIFICATION FOR 50% OF THE CREW. IF THIS IS NOT COMPLETED ALLVESSELS WITHIN YOUR COMPANY MAY BE REQUIRED TO STOP OPERATION UNTIL COMPLETED.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Navigation
Issued 6 June 2001 Resolved
PROVIDED NAVIGATION PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
REGISTER EPIRB WITH NOAA.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 6 June 2001 Resolved
REMOVE DUCT TAPE FROM WIRE CONNECTIONS AT OPEN BRIDGE, AND REPAIR THEM PROPERLY. COVER ALL EXPOSED JUNCTION BOXES AND SWITCHES WITH THE CORRECT COVERS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 6 June 2001 Resolved
PROVIDE COVERS FOR ALL EXPOSED LIGHT BULBS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 6 June 2001 Resolved
INSTALL CO2 BOTTLE ACTIVATOR FOR B-5 FIRE EXTINGUISHER.
Condition: Unknown
Due 7 October 2004
Resolved 7 October 2004
Lifesaving
Issued 6 June 2001 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON PORT LIFEFLOAT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
INSTALL WATERLIGHT ON STBD LIFEFLOAT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
PAINT NAME OF VESSEL ON ALL LIFERINGS. PROVIDE REQUIRED 1 LIFERING WITH 60'ATTACHED LINE AND WATERLIGHT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Construction/Loadline
Issued 6 June 2001 Resolved
MAKE STEERING ROOM HATCH WATERTIGHT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Fire Fighting
Issued 6 June 2001 Resolved
PROVIDE 1(EA) B-I FIRE EXTINGUISHER AND BRACKET AT THE OPEN BRIDGE OPERATING STATION.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 6 June 2001 Resolved
MAKE OPERABLE THE PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Construction/Loadline
Issued 6 June 2001 Resolved
MAKE OPERABLE ALL HIGH BILGE LEVEL ALARMS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 June 2001 Resolved
MAKE OPERABLE THE NAVIGATIONAL RADAR.
Condition: Unknown
Due 7 October 2004
Resolved 7 October 2004
Resolution: 07OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline
Issued 6 June 2001 Resolved
PROVIDE AN OIL POLLUTION PLACARD.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Construction/Loadline
Issued 6 June 2001 Resolved
MAKE AFT ENGINE ROOM HATCH OPERABLE AND WATERTIGHT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Construction/Loadline
Issued 6 June 2001 Resolved
MAKE FORWARD ENGINE ROOM HATCH OPERABLE AND WATERTIGHT.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Engineering
Issued 6 June 2001 Resolved
INSTAL MACHINERY GUARDS OVER BELTS ON PORT ENGINE.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 6 June 2001 Resolved
MAKE OPERABLE ENGINE ROOM LIGHTING WITH PROPER GUARDS AND COVERS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 6 June 2001 Resolved
CLEAN ALL OIL FROM GENERATOR WIRING, MAKE PROPER CONNECTIONS AND ROUTE PROPERLY.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Engineering
Issued 6 June 2001 Resolved
MAKE OPERABLE STBD EMERGENCY FUEL SHUT-OFF.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 6 June 2001 Resolved
REMOVE ALL UNUSED WIRING FROM ENGINE SPACE.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 9 November 1998 Resolved
MAKE TEMPORARY REPAIRS TO BOAT RAMP TO ENABLE VEHICLES TO SAFELY USE THEM PRIOR TO SAILING.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Lifesaving
Issued 9 November 1998 Resolved
REMOVE EXCESS OIL IN BILGES PRIOR TO SAILING.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Documentation
Issued 6 November 1998 Resolved
PROVIDE THIS OFFICE WITH A WRITTEN DRYDOCK EXTENSION REQUEST WITH A VALID DATE FOR DRYDOCK PRIOR TO CARRYING PASSENGERS OR FREIGHT FOR HIRE.
Condition: Unknown
Due 31 January 1999
Resolved 11 November 1998
Documentation
Issued 6 November 1998 Resolved
THE VESSEL IS NOT TO CARRY PASSENGERS OR FREIGHT FOR HIRE UNTIL A DRY DOCK EXTENSION EXAM IS COMPLETED BY A COAST GUARD INSPECTOR AND THE DRYDOCK EXTENSION IS APPROVED.
Condition: Unknown
Due 31 January 1999
Resolved 11 November 1998
Documentation
Issued 6 November 1998 Resolved
PROVIDE THIS OFFICE WITH A GUARANTEED DRYDOCK DATE AT A REPUTABLE DRYDOCK FACILITY PRIOR TO CARRYING PASSENGERS OR FREIGHT FOR HIRE.
Condition: Unknown
Due 31 January 1999
Resolved 11 November 1998
Lifesaving
Issued 31 October 1997 Resolved
PROVIDE 6 RED FLARES.
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Fire Fighting
Issued 31 October 1997 Resolved
STENCIAL FIRE AXES WITH THE NOME OF THE VESSEL
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Unknown
Issued 31 October 1997 Resolved
PUT COVER BACK ON DECK OF FLYING BRIDGE BY HELM STATION
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
STENCIL LIFEJACKET LOCKERS WITH THE TYPE AND NUMBER OF LIFEJEACKETS STOWED INSIDE.
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
REPLACE RING BOUY LOCATED ON FLYING BRIDGE
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Unknown
Issued 31 October 1997 Resolved
COMPLETE IFR WORKLIST
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Navigation
Issued 31 October 1997 Resolved
REPAIR VESSEL'S HORN
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Fire Fighting
Issued 31 October 1997 Resolved
PROVIDE SERVICE REPORT FOR ALL FIRE EXTINGUISHERS._x001C_ _x001C_ VESSEL CAN NOT OPERATE UNTIL THIS REQ IS CLEARED.
Condition: Unknown
Due 4 November 1997
Resolved 14 November 1997
Electrical
Issued 31 October 1997 Resolved
INSTALL BLANK ON AFT ELECTICAL PANEL ON BRIDGE
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
STENCIAL PADDLES WITH THE NAME OF THE VESSEL
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 8 October 1996 Resolved
PROPERLY MOUNT LIFE FLOAT WATERLIGHT TO BULKHEAD
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Fire Fighting
Issued 8 October 1996 Resolved
PROVIDE APPROVED MARINE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Lifesaving
Issued 8 October 1996 Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD IN A FLOAT FREE ARANGEMENT, AFCC ACCEPTED, CATEGORY 1, 406MHZ EPIRB.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Documentation
Issued 8 October 1996 Resolved
COMPLETE IFR WORKLIST ISSUED 28OCT96 TO BRING VESSEL IN COMPLIANCE WITH INTERM FINAL RULE.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Fire Fighting
Issued 30 October 1995 Resolved
COMPLETE SERVICING OF VESSEL'S TYPE B-V PORTABLE FIRE EXTINGUISHER(PROVIDE NITROGEN PROPELLANT BOTTLE FOR THE SYSTEM.) VESSEL MAY NOT TRANSPORT ANY FLAMMABLE OR COMBUSTIBLE LIQUID THAT IS TRANSPORTED IN A PORTABLE TANK OR TANK TRUCK UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Fire Fighting
Issued 30 October 1995 Resolved
STENCILE VESSEL'S NAME ON FIRE AXE.
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Construction/Loadline
Issued 25 April 1995 Resolved
REMOVE ALL COVERS FROM REQUIRED FREEING PORTS._x001C_
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Lifesaving
Issued 31 October 1994 Resolved
STENCIL VESSEL NAME AND PERSONS CAPACITY ON LIFE FLOATS, MINIMUM TWO INCH LETTERS._x001C_
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Engineering
Issued 31 October 1994 Resolved
STENCIL FUEL TANK FILL AND VENT PIPES LOCATED ON DECK._x001C_
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 16 November 1992 Resolved
Replace broken glass in windshield on navigation bridge.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Navigation
Issued 16 November 1992 Resolved
Repair rudder angle indicator sending unit arm located in lazarette.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Engineering
Issued 16 November 1992 Resolved
Provide stainless steel protective bowl for Racor fuel filter on generator.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Construction/Loadline
Issued 16 November 1992 Resolved
Repair and/or adjust aft watertight door in engine room to make it watertight.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 16 November 1992 Resolved
Complete servicing of semi-portable fire extinguisher located on bridge.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Documentation
Issued 16 November 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Lifesaving
Issued 16 November 1992 Resolved
Provide waterlight for lifefloat. Vessel is restricted to daytime operations until completed.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 16 November 1992 Resolved
DEMONSTRATE FIRE PUMP OPERATION WITH A MINIMUM PITOT TUBE PRESSURE OF 50 PSI AT THE HOSE OUTLET.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Electrical
Issued 19 November 1991 Resolved
Label all emergency lights with an "E" of contrasting color to the background.
Condition: Unknown
Due 1 December 1991
Resolved 4 February 1992
Navigation
Issued 19 November 1991 Resolved
Label the hydraulic steering valve manifold in lazarette to indicate which valves are identified in chart.
Condition: Unknown
Due 1 December 1991
Resolved 25 March 1992
Construction/Loadline
Issued 19 November 1991 Resolved
Make new cable penetration in aft engine room bulkhead watertight.
Condition: Unknown
Due 1 December 1991
Resolved 4 February 1992
Construction/Loadline
Issued 19 November 1991 Resolved
Make both watertight doors leading into engine room watertight.
Condition: Unknown
Due 1 December 1991
Resolved 4 February 1992
Engineering
Issued 19 November 1990 Resolved
INSTALL A REMOTE EMERGENCY FUEL SHUT-OFF ON THE FUEL SUPPLY LINE AT THE TANK DISCHARGE WHICH WILL REACH TO THE DECK ABOVE THE FUEL SPACE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Lifesaving
Issued 19 November 1990 Resolved
PAINT VESSEL'S NAME ON PADDLES AND PROVIDE A 6 FT. BOAT HOOK FOR THE LIFE FLOAT.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Lifesaving
Issued 19 November 1990 Resolved
PROVIDE AND ATTACH LIGHTS TO THE SIX LIFE PRESERVERS WHICH DO NOT HAVE LIGHTS. TOTAL PRESERVERS IS TWELVE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Fire Fighting
Issued 19 November 1990 Resolved
SERVICE THE SEMI-PORTABLE B-V EXTINGUISHER IN THE PRESENCE OF A QUALIFIED COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Engineering
Issued 19 November 1990 Resolved
PROVIDE AND INSTALL A STAINLESS STEEL CUP ON THE BASE OF THE RACOR FUEL FILTER.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Engineering
Issued 8 August 1987 Resolved
NONDESTRUCTIVELY TEST THE TAIL SHAFTS BY A QUALIFIED PERSON PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 8 August 1987
Resolved 8 August 1987
Engineering
Issued 1 December 1986 Resolved
INSTALL AN OPERATIONAL EMERGENCY SHUTDOWN FOR EACH MAIN ENGINE FROM THE BRIDGE. BY 01FEB86
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Lifesaving
Issued 26 February 1985 Resolved
REPLACE ALL OUT DATED HAND HELD ORANGE SMOKE AND RED FLARE DISTRESS SIGNALS
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Construction/Loadline
Issued 26 February 1985 Resolved
REPAIR OR REPLACE WEATHERTIGHT DOOR PORT SIDE OF WHEELHOUSE.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.