← All vessels
DLM17
Industrial Vessel · Miscellaneous Vessel class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named DLM17
DLM17 is a 1981 industrial vessel. The Coast Guard has recorded 27 inspections since 1987, most recently in June 2019, along with 6 deficiencies and 1 operational control.
Records from 1987 to 2019. Most recent: operational control imposed, 19 June 2019.
- Built
- 1981
- Last inspected
- 12 June 2019
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
645252
205299
Flag
UNITED STATES
—
Maury page id
psix-205299
Inspections, by type
…with no type recorded3
Years with a record
13 calendar years (1987–2019)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)130.1 ft × 32.1 ft × 7.7 ft
Registered tonnagegross 369 / net 369
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderL A D CONSTRUCTION CO · GIBSON LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMERIDIAN, GA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it369 - Regulatory (Subpart C or D), Gross Ton
369 - Regulatory (Subpart C or D), Net Ton
369 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
12 June 2019
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6712453
21 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 71193
20 April 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 791262
31 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781577
25 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117229
27 June 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422859
21 June 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383282
5 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 881449
10 May 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458224
27 March 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448646
8 July 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173838
21 June 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1334349
26 May 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385243
4 May 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151042
29 April 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373840
30 March 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373823
3 June 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389568
13 May 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384964
20 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208534
1 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225805
29 June 1990
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927022
12 April 1989
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888319
12 April 1989
MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349145
30 June 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209774
4 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1037921
28 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031515
13 May 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029701
Deficiency record · 6
Fire Fighting
Issued 21 June 1996
Resolved
DEMONSTRATE PROPER OPERATION OF MAIN FIREFIGHTING PUMP. AUXILLARY WATER PUMP IS AUTHORIZED TO BE USED AS FIRE PUMP UNTIL SUCH TIME AS REPAIRS ARE COMPLETED.
Construction/Loadline
Issued 26 May 1994
Resolved
MAKE PERMANENT REPAIRS OR REPLACE ENGINE ROOM ESCAPE HATCH LOCATED STARBOARD SIDE OF VESSEL.
Deck/Cargo
Issued 30 March 1993
Resolved
VESSEL IS NOT ALLOWED TO CARRY HYDROCHLORIC ACID IN ANY FIXED OR PORTABLE TANKS UNTIL SUCH CARRIAGE IS APPROVED BY THE U. S. COAST GUARD.
Deck/Cargo
Issued 30 March 1993
Resolved
MAKE ALL FOUR DRY BULK TANKS AVAILABLE FOR INTERNAL EXAMINATION BY A USCG MARINE INSPECTOR.
Construction/Loadline
Issued 13 May 1987
Resolved
AT NEXT DRYDOCK INSPECTION ALL PIPING OUTBOARD OF SHUT-OFF VALVES SHALL BE AT LEAST SCHEDULE 80.
Fire Fighting
Issued 13 May 1987
Resolved
PROVIDE APPROVED FIRE PLAN.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.