Records from 2002 to 2025. Most recent: inspection, 25 August 2025.
Documentation record
Registered dimensions (L × B × D)78.9 ft × 38.0 ft × 8.0 ft
Registered tonnagegross 194 / net 132
ITC dimensions (L × B × D)78.9 ft × 38.0 ft × 8.0 ft
ITC tonnagegross 277 / net 83
BuilderBLUE STREAK IND INC · CHALMETTE, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 September 2025 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it194 - Regulatory (Subpart C or D), Gross Ton
277 - Convention (Subpart B), Gross Ton
132 - Regulatory (Subpart C or D), Net Ton
83 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
25 August 2025
Periodic Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8218315
15 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8019381
4 September 2024
Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7996388
26 June 2024
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7943184
22 June 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7998014
11 December 2023
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7837557
8 November 2023
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7825203
8 September 2022
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7622733
29 August 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7546086
13 June 2022
Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7476636
9 June 2022
Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7472667
31 May 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7472094
11 August 2021
MTSA Verification · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7283494
10 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7057891
23 August 2019
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6792741
17 July 2019
Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6758901
20 July 2018
Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6488285
2 May 2017
Examination of Repairs · Hull Examination · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6137935
28 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5956062
13 July 2016
Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5939646
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 November 2023
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Test found solenoid valve inoperable. 33 CFR 83.33(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 December 2023
Resolution: Ship's whistle solenoid was replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 21 November 2023
Resolved
The inspector shall examine all accessible parts of the vessel's hull,machinery, and equipment to be assured that it is in a satisfactory condition. Forward pilothouse bulkhead at main deck contained a cracked weld allowing water intrusion into fiddley space. 46 CFR 91.27-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 December 2023
Resolution: Pilothouse to deck weld connection was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 November 2023
Resolved
A rescue boat and its installation shall be acceptable to the OCMI for the rescue of persons accidentally falling over the side. Nylon lifting straps were worn and original material supplied with rescue boat in 2019. The straps shall have a design safety factor of 6 times the max working load. 46 CFR 94.10-10(e), District 8 Rescue Boat Policy Nov 12,1998
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2023
Resolution: Rescue boat lifting strap was replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 August 2022
Resolved
Cranes and other hoisting machines with their accessory gear, at least once in each five years, shall be tested with a proof load which shall exceed the safe working load as set forth in Table 91.37-40(a).If the boom of the crane has a movable radius, it shall be tested
with a proof load as set forth in this section at the maximum and minimum radius of the boom. Port side Nautilus crane is rated for 26.8 tons safe working load and was initially load tested on 9/06/22, but did not achieve 5 ton in excess due to wire rope coming out of sheave groove. Vessel completed a follow up test at 25% (2,300 lbs) in excess that is reserved for cargo gear not exceeding 20 tons. Test was only completed at one angle. Starboard EBI crane with a safe working load of 9.7 tons was tested at the required 25% excess, but only at one angle. 46 CFR Subchapter Old I, 46 CFR 91.37-3(a), 46 CFR 91.37-40(a), 46 CFR 91.37-40(d).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2023
Resolution: Received remianing documentation showing 2nd angle load test was completed.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 29 August 2022
Resolved
Pressure vessel (PV) gauges shall be no less than 1.2 times nor more than 2 times the pressure at which the pressure relief valve is set. The PV gauge was inoperable & the relief valve did not have a tag to determine its actual setting. Vessel shall replace/repair gauge & identify/mark pressure relief valve setting prior to getting underway. 46 CFR 54.15-5(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2022
Resolution: Replaced relif valves and gauges.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 August 2022
Resolved
General alarms shall be supplemented with a flashing red light in locations where noise levels are too high to hear the audible alarm. The port side engine room general alarm flashing red light stopped working during the inspection. Vessel shall replace/repair the flashing red light prior to getting underway. 46 CFR 113.25-10(d)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2022
Resolution: Light was repaire dand tested satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 August 2022
Resolved
Emergency lighting shall be operated & inspected at least once a week while the vessel is underway. The emergency light in berthing area "A" was inoperable & the emergency light in the starboard engine room was too dim to provide adequate lighting for egress. Vessel shall replace/repair the emergency lights prior to getting underway. 46 CFR 97.15-30(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2022
Resolution: Lights were repaired and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 August 2022
Resolved
Means shall be provided to close of all vents. A few of the vents on the main deck were unable to be closed due to broken/missing closure devices. Vessel shall ensure all vent closures are in working order prior to getting underway. 46 CFR 92.15-10(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2022
Resolution: Vessel provided photographic evidence of repaired/replaced vent closures.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 August 2022
Resolved
Lifefloats shall be marked with the vessel's name & number of persons allowed. The port lifefloat's markings were faded & becoming unreadable. Vessel shall re-mark the required markings on the lifefloats. 46 CFR 97.37-40(a)
46 CFR 97.37-40(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2022
Resolution: Company provided photographic evidence of proper lifefloat markings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2022
Resolved
At each inspection for certification the inspector shall determine that all fire fighting equipment is in suitable condition. The main deck fire axe blade is wasted. Vessel shall replace fire axe. 46 CFR 91.25-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2022
Resolution: Fire ax was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 August 2018
Resolved
Overspeed trips were not calibrated or installed for port and starboard generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2018
Resolved 4 September 2018
Resolution: Overspeeds were installed and tested satisfactory.
Engineering › Reduction Gearing/Clutches › Gear
Issued 26 May 2017
Resolved
Vessel did not have L/O analysis completed for 5 yr Leg credit IAW CG-543 Policy Ltr.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 13 June 2017
Resolution: Analysis recieved.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 May 2017
Resolved
2 BII portable extinguishers in Galley were found not annually inspected. Crew to have 3rd party provide inspection.
Condition: Improper/Lack of Maintenance
Due 2 June 2017
Resolved 15 June 2017
Lifesaving › Lifefloat › Painter
Issued 26 May 2017
Resolved
Lifefloat painter line was worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Painter line replaced.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 26 May 2017
Resolved
Rescue boat contains thru hull fasteners that lifting straps attach to place boat in water. Two fasteners were cut short causing locking nuts not to be installed correctly. Crew to replace.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: fasteners were replaced.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 July 2016
Resolved
Draft and Loadline marks are not visible and need to be repainted in contrasting color to the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 1 August 2016
Resolution: Painted
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 28 July 2016
Resolved
#1 Steering power failure alarm did not work properly and needs to be fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 1 August 2016
Resolution: Alarm repaired.
Lifesaving › Lifefloat › Painter
Issued 28 July 2016
Resolved
The two lifefloats were not attached to painter correctly. Painter was intended to be linked in series, however one lifefloat was not actually attached and must be corrected.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 1 August 2016
Resolution: Painter line correctly installed.
Construction/Loadline › Structures › Air Pipe
Issued 28 July 2016
Resolved
Exhaust hangers for port engine exhaust has cracked welds and needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 1 August 2016
Resolution: Exhaust hangers repaired.