MAURY USCG vessel records Sign in
← All vessels

EXPLORER

EXPLORER is a 1982 towing vessel. The Coast Guard has recorded 11 inspections since 1992, most recently in April 2024, along with 31 deficiencies and 1 operational control.

Records from 1992 to 2024. Most recent: inspection, 30 April 2024.

Built
1982
Last inspected
30 April 2024
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4448
205585
Flag
UNITED STATES
—
Maury page id
psix-205585

Inspections, by type

…with no type recorded3
Years with a record 10 calendar years (1992–2024)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)41.1 ft × 18.9 ft × 6.1 ft
Registered tonnagegross 52 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · ST LOUIS · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

30 April 2024 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7904267
3 May 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7680662
10 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7448060
15 June 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7228353
14 May 2020 Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6957911
2 July 2013 Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4639397
22 January 2007 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2860002
1 July 2005 Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2410165
26 June 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 419052
2 April 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 414833
18 September 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 132969

Deficiency record · 31

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2024 Resolved
Each towing vessel must have either a self-priming power driven pump or portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. On board portable fire pump was not operational. Repair or replace and test the on board portable fire pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2024 Resolved
An approved 160B semi-portable fire-extinguishing system to protect the engine room; Place on board and attach the vessels 160-B semi-portable fire extinguisher.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 30 April 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists to include a low lubricating oil pressure alarm. The vessel’s crew identified that the main diesel engine oil pressure alarm did not function properly. Repair and test low lube oil pressure alarm on main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 2 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 April 2024 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions. Install emergency lighting or phosphorescent adhesive lighting strips along escape hatches/doorways.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 30 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 April 2024 Resolved
The following systems must be equipped with gauges at the machinery location, (1) Main engine lubricating oil pressure and main engine RPM. Vessel did not have main engine RPM gauges installed at the machinery location, also the STBD main engine lubricating oil pressure gauge was inoperable at the machinery location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 2 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 April 2024 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Pressure vessel relief valves, twice every 5 years, with no more than 3 years elapsing since last test. The installed relief valve had no record of testing or replacement since 2020. Test or replace pressure vessel relief valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 30 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 April 2024 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage, including. (3) Coast Guard light list. Vessel had light list dated 2021 on board, update on board light list to newest version.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 30 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2023 Resolved
160-B Semi portable fire extinguisher must be secured to the vessel in a location close enough to allow the attached hose to reach the spaces in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 19 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 May 2023 Resolved
Floating water light attached to port side ring buoy had an expired battery. Replace battery and mark expiration date on battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 19 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2023 Resolved
Emergency Exits must be marked "Emergency Exit, Keep Clear".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 19 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 3 May 2023 Resolved
Industrial type first aid kit must be on board. Current kit had expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 19 May 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 May 2023 Resolved
Alarm set points must be tested twice every 5 years not to exceed 3 years IAW 46 CFR 61.40-10. Test alarm set point and provide report to attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 19 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2021 Resolved
Provide onboard 6 distress signals and stowage container marked "DISTRESS SIGNALS"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 29 June 2021
Resolution: Owner purchased flare kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2021 Resolved
Provide a floating electric water light on starboard ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 29 June 2021
Resolution: Owner purchased new waterlights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2021 Resolved
Each floating waterlight needs a 3-6 ft lanyard around the body of the buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 29 June 2021
Resolution: Owner attached appropriate sized lanyards.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 June 2021 Resolved
Provide a means to close ventilation for intake air vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 29 June 2021
Resolution: Owner installed ventilation dampners.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 June 2021 Resolved
Provide records of nav assessments being preformed before each voyage at next annual inspection.
Action required: 705 - Other - as specified
Resolved 21 September 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 June 2021 Resolved
The original COI must be present on the vessel at all times.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2021
Resolved 17 June 2021
Resolution: Master was unable to locate COI. Requested additional copy.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 June 2021 Resolved
Show proof of valid MMC and have it present onboard during any operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2021
Resolved 15 June 2021
Resolution: Although MMC was not onboard the vessel, Master was able to find MMC and send picture after the inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2021 Resolved
Show proof of DAPI program and associated documents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2021
Resolved 26 August 2021
Resolution: DAPI Program implemented
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 15 June 2021 Resolved
Show proof of marine radio operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2021
Resolved 26 August 2021
Resolution: Marine operator permit validated
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 July 2020 Resolved
Remove oily residue in bilges and provide proof of offload.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 22 July 2020
Resolution: Oily residue removed from the bilge and entered into log book. Photo proof received.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2020 Resolved
Provide BC-40 portable fire extinguisher for flammable storage locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 22 July 2020
Resolution: Provided an inspected and tagged BC-60 to place near flammable storage locker. Photo proof recieved.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2020 Resolved
Relocate flammable materials outside of tool room, away from ignition sources.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Owner sent picture of relocated flammable storage locker.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 July 2020 Resolved
Weld hole in deck/bulkhead seam in tool room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Owner sent proof of repiar by using JB weld epoxy.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 July 2020 Resolved
Provide onboard dedicated fire axe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Owner provided picture of mounted fire axe.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020 Resolved
Provide proof of appropriate setting and function of relief valve on pressure vessel. MAWP 200 PV 175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 14 August 2020
Resolution: Owner prvided video of satisfactory relief valve pressure test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 July 2020 Resolved
Replace gaskets on void hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Owner provided picture of replaced gaskets installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2020 Resolved
Provide cap on wire on stbd main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Owner provided picture of cap on exposed wire.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 July 2020 Resolved
Provide proof of machinery alarm set points.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Owner sent objective evidence of third party mechanic conducting alarm set points. Saved in vessel documents.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Condition
Issued 1 July 2005 Resolved
Properly install a B-V semi-portable fire extinguisher on board vessel.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Resolution: Company representative provided proof of purchase to the COTP SUMR of B-V semi-portable fire-extinguishing system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.