← All vessels
GAMBLER
GAMBLER is a 1982 towing vessel. The Coast Guard has recorded 9 inspections since 2010, most recently in September 2025, along with 64 deficiencies and 1 operational control.
Records from 2010 to 2025. Most recent: inspection, 19 September 2025.
- Built
- 1982
- Last inspected
- 19 September 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 64 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
645675
WDK8562
205608
Flag
UNITED STATES
366998310, 368095340
Maury page id
psix-205608
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)55.3 ft × 22.0 ft × 7.4 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHAISSON WELDING SERVICE · CUT OFF, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLE CHASSE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 August 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK8562MMSI 368095340 · active · compulsorily equipped · granted 24 May 2019, expires 24 May 2029
WTG3900MMSI 366998310 · active · compulsorily equipped · granted 11 August 2017, expires 22 October 2027 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 9
19 September 2025
COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8237601
3 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8013919
24 August 2023
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7775517
27 June 2022
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7271660
3 September 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7049205
11 August 2020
Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7030228
11 February 2016
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5812778
2 April 2013
Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4561697
2 April 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3707775
Deficiency record · 64
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 December 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MIs observed a fuel leak on the port side generator on a high pressure fuel line. 46 CFR 143.220
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 December 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MIs observed a fuel leak on the port side generator on a high pressure fuel line. 46 CFR 143.220
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MIs observed bilge pump not properly secured in engine room. 46 CFR 143.205
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MIs observed uncapped electrical wires on the starboard generator. 46 CFR 143.205(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 December 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MIs observed starboard steering ram set pin to be loose and allowing excessive movement in on deck steering system. Replace set pin with proper diameter pin. 46 CFR 143.205
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 December 2025
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed a loose connection on the negative battery terminal of the starboard generator battery. 46 CFR 143.400(e)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 September 2025
Resolved
Vessel rep informed CG that vessel will not be ready or able to schedule and/or complete an annual inspection prior to 27SEPT2025, which is 3 months after COI anniversary date.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 October 2024
Resolved
No visual and audible bilge alarm indication at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2024
Resolved
Bilge piping holes and patched in numerous locations.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 October 2024
Resolved
Excessive oil in engine room bilge and on deck plates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 October 2024
Resolved
Fuel leak on starbard generator fuel filter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2024
Resolved
Starboard main engine mount shims dislodged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2024
Resolved
Floating electronic marker lights found inoperable with incorrect batteries installed in both.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 October 2024
Resolved
Towing vessel record not maintained for previous voyages. Vessel is required to submit logs for inspection after 30 days of operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 October 2024
Resolved
Main engine gauges need to be mounted in plain sight in one location for each engine.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 October 2024
Resolved
All electrical connections in pilot house console must lead to a junction box/s.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 October 2024
Resolved
Starboard main engine oil pressure gauge and port generator tachometer inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 October 2024
Resolved
Engine room lighting secured with zip ties and must be permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2024
Resolved
40-B fire extinguisher at flammable storage locker past its annual servicing.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 October 2024
Resolved
Clothing dryer blocking aft engine room egress.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 October 2024
Resolved
Machinery guard on both main engine rotating machinery.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 September 2023
Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. MI identified radio would not turn on when vessel had no power. Install battery backup for VHF-FM radio on bridge to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MI discovered fuel leaking from discharge transfer pump piping. Renew piping to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2023
Resolved
Flammable and combustible products must not be stored in machinery space, unless they are stored in a suitable container that meets the requirements of 142.225 of this subchapter. MI observed oil and rags not in containers in engine room. Remove oil and rags from engine room to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2023
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection. MI identified fire extinguisher above engine room with no charge. Replace/service fire extinguisher with proper charge to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
MI discovered missing blanks on electrical panel in galley. Add blanks to panel in galley to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 September 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. MI observed emergency lighting in galley inoperable. Renew emergency lighting in galley to operate as required to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 September 2023
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Port side lifebouy light was not operating. Renew light to the satisfaction of the Marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 September 2023
Resolved
All new equipment and installations must meet the applicable requirements in this part for new vessels. MI observed improper bracket for extinguisher on bridge. Affix proper bracket with proper fire extinguisher to the satisfaction of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 September 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. MI discovered edge of port door on bridge was deteriorating. Renew metal on edge to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2023
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi portable fire extinguisher behind pilothouse was not secured. Secure extinguisher to the satisfaction of the MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions.
Wire nuts on bridge need to be secured in a manner they
will not vibrate loose. Dead end wires behind pilot
house need to be removed or secured. Outlet on bridge
not secured.
Each vessel must be equipped with at least two operable
portable battery lights. One of these lights must be
located at the operating station and the other at the
access to the propulsion machinery space.
46 CFR 143.205 (a)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 June 2022
Resolved
Each towing vessel must be equipped with navigation
lights, shapes, and sound signals in accordance with the
International Regulations for Prevention of Collisions
at Sea (COLREGS) or 33 CFR part 84 as appropriate to its
area of operation.
Anchor light is extinguished.
46 CFR 140.720
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 27 June 2022
Resolved
Where systems installed on vessels for wash water, as
defined in § 1250.3(n), do not comply with the
requirements of a potable water system, prescribed in §
1250.82, they shall be constructed so as to minimize the
possibility of the water therein being contaminated. The
storage tanks shall comply with the requirements of §
1250.83, and the distribution system shall not be cross
connected to a system carrying water of a lower sanitary
quality. All faucets shall be labeled “Unfit for
drinking”.
Apply labeling and update health and safety plan.
21 CFR 1250.87
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022
Resolved
The master of a towing vessel must ensure that drills
are conducted and instructions are given to ensure that
all crewmembers are capable of performing the duties
expected of them during emergencies. This includes
abandoning the vessel, recovering persons from the
water, responding to onboard fires and flooding, or
responding to other threats to life, property, or the
environment.
Conduct drills and log in TVR log book
46 CFR 140.420
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 27 June 2022
Resolved
The officer in charge of a navigational watch must
conduct a navigation assessment for the intended route
and operations prior to getting underway. The navigation
assessment must incorporate the requirements of
pilothouse resource management of § 140.640, assess
operational risks, and anticipate and manage workload
demands.
Update log book with all minimum requirements.
46 CFR 140.635
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022
Resolved
All crewmembers must be provided with health and safety
information and training that includes:
No means of lock out/Tag out on board vessel.
46 CFR 140.515 (a)(9)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 June 2022
Resolved
Fuel systems for towing vessel main engines and
generators must have a documented maintenance plan to
ensure proper operation of the system.
Vessel does not have a maintenance plan.
46 CFR 143.255
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 27 June 2022
Resolved
All alcohol testing devices used to meet the
requirements of this part must be currently listed on
either the Conforming Products List (CPL) titled “Modal
Specifications for Devices To Measure Breath Alcohol” or
“Conforming Products List of Screening Devices To
Measure Alcohol in Bodily Fluids,” which are published
periodically in the Federal Register by National Highway
Traffic Safety Administration (NHTSA).
Incorrect test was on vessel.
46 CFR 4.06-15
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 27 June 2022
Resolved
(1) A manned U.S. ship (other than a fixed or floating
drilling rig or other platform) that is 26 feet or more
in length; (2) A manned floating drilling rig or other
platform in transit that is subject to the jurisdiction
of the United States; or (3) A manned ship of 40 feet or
more in length that is operated under the authority of a
country other than the United States while in the
navigable waters or the Exclusive Economic Zone of the
United States.
Vessel did not have garbage placard displayed on board.
33 CFR 151.59
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2022
Resolved
The following systems must be equipped with gauges at
the machinery location: (1) Main engine lubricating oil
pressure and main engine RPM; (2) Main engine cooling
water temperature; (3) Auxiliary generator engine
lubricating oil pressure and auxiliary generator engine
RPM; (4) Auxiliary generator engine cooling water
temperature; and (5) Hydraulic steering fluid pressure,
if the vessel is equipped with hydraulic steering
systems.
Engines and generators are missing required gauges.
46 CFR 143.230 (c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions.
Port MDE oil and Stbd MDE JW gauges at operating station
were inoperable. Oil leak on port MDE.
46 CFR 143.205
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2022
Resolved
The strength of each component used for securing the
towing vessel to the tow and for making up the tow is
adequate for its intended service. The Marine Inspector
(MI) observed there was significant wastage of the metal
on both forward winches. Repair or replace in kind.
46 CFR 140.801(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022
Resolved
The hose must be a lined commercial fire hose...and
fitted with a nozzle made of corrosion-resistant
material capable of providing a solid stream and a spray
pattern. The MI observed the chain which keeps the
nozzles stream control attachment connected to the unit
was missing.
46 CFR 142.325 (d)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 June 2022
Resolved
An existing vessel may be deemed by the OCMI to be in
compliance provided that the vessel has been in
satisfactory service insofar as structural adequacy is
concerned and does not cause the structure of the vessel
to be questing by the OCMI. The MI observed wastage
around the watertight seal of the starboard side window.
Repair in kind.
46 CFR 144.200(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation and safety of
persons onboard. The MI observed the starboard
generator's windings need to be cleaned.
46 CFR 143.205
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation and safety of
persons onboard. The MI observed the unfired pressure
vessel has a gauge that is cracked and has a range that
exceeds 2 to 2.4 times the MAWP. Replace gauge.
46 CFR 143.205
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation and safety of
persons onboard. The MI observed the washing machine in
the machinery space was not secured or strapped in place
to prevent movement.
46 CFR 143.205
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2022
Resolved
Alternate arrangements or equipment to comply with this
part may be approved in accordance with 136.115 of the
subchapter. The MI observed the paint locker was not
properly sealed and is of an aluminum type. Please
discontinue use as a paint locker or provide repair and
provide a request for alternate arrangement
consideration.
46 CFR 142.210(a)
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 June 2022
Resolved
Electrical components that pose an electrical hazard
must be in an enclosure. The MI observed the enclosure
for the electrical outlet above the galley sink in not
functioning as designed. Repair or replace in kind.
46 CFR 143.400(g)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 June 2022
Resolved
The master must ensure that all hatches, doors, and
other openings designed to be watertight or weathertight
function properly. The galley access door does not seal
properly. Repair or replace in kind.
46 CFR 140.610(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022
Resolved
Each towing vessel must be equipped with an industrial
type first aid cabinet or kit. The MI observed there are
expired items in the first aid kit. Make sure all items
are not expired.
46 CFR 140.435
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2022
Resolved
Means must be provided for stopping each fan in a
ventilation system serving machinery spaces and for
closing. The MI observed wastage at the lowest elbow of
the ventilation into the machinery space. Repair or
replace to ensure functioning as designed.
46 CFR 144.605
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation and safety of
persons onboard. The MI observed the pressure relief
valve on the water heater is not piped to the bilge to
protect crewmembers.
46 CFR 143.205
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2022
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation and safety of
persons onboard. The MI observed the latch to secure the
oven door was missing.
46 CFR 143.205
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 27 June 2022
Resolved
Where systems installed on vessels for wash water, as
defined in § 1250.3(n), do not comply with the
requirements of a potable water system, prescribed in §
1250.82, they shall be constructed so as to minimize the
possibility of the water therein being contaminated. The
MI observed there were no bug screens over the wash
water vents.
21 CFR 1250.87
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date the action for this deficiency shall be changed to a 60(Rectify deficiencies prior to movement) and they vessel may no longer be permitted to operate.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 August 2020
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and ensure the following: All bilge and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Marine inspectors found diesel, oil and water along with wood deck plates in the engine room. Remove, clean and properly dispose of water and oils in the bilge and replace wood floors with appropriate material.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Vessel had open wiring under the the cabinets, engine room and throughout the vessel. Remove or properly cap all lose wire to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020
Resolved
Piping and machinery components that exceed 220 Celsius including fitting, flanges, valves exhaust manifolds and turbochargers must be insulated. Marine Inspectors found severe degradation on the exhaust stack.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2020
Resolved
Each towing vessel must carry at least one appropriately sized life jacket, for each person on board... Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked. Vessel is required to properly mark, label and provide proper attachments to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 August 2020
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to propulsion engine or generator prime mover. Vessels fuel shut off valve was not permantly affixed to deck and could not be found by Marine inspectors directly outside the tank. Properly attach fuel shut off for remote operation along with directly outside the tank.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 August 2020
Resolved
The master must ensure that all hatches, doors, and other opening designed to be wateright or weathertight function properly. Vessels aft door was missing gasket material. Replace gasket for door and verify proper seal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life property and environment. Vessel owner stated vessel is on a Lakes, Bays, sounds route. Vessel does not have life saving equipment, navigation equipment for the route and Marine inspectors did not complete an exam to verify key items not listed above due to no crew on board. Vessel is required to have a Coast Guard inspection prior to movement to verify major systems on the vessel and crew knowledge meets the regulations and route intended.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.