GAMBLER

Built
1982
Last inspected
19 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 19 September 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2010–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8562
205608
Flag
UNITED STATES
Maury page id
psix-205608

Documentation record

Registered dimensions (L × B × D)55.3 ft × 22.0 ft × 7.4 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHAISSON WELDING SERVICE · CUT OFF, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELLE CHASSE, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 June 2025 · expires 31 July 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 64 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

19 September 2025 COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8237601
3 October 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8013919
24 August 2023 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7775517
27 June 2022 Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7271660
3 September 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7049205
11 August 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7030228
11 February 2016 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5812778
2 April 2013 Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4561697
2 April 2010 Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3707775

Deficiency record · 64

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 December 2025 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MIs observed a fuel leak on the port side generator on a high pressure fuel line. 46 CFR 143.220
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 12 December 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 December 2025 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MIs observed a fuel leak on the port side generator on a high pressure fuel line. 46 CFR 143.220
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 12 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MIs observed bilge pump not properly secured in engine room. 46 CFR 143.205
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 12 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MIs observed uncapped electrical wires on the starboard generator. 46 CFR 143.205(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 12 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 December 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MIs observed starboard steering ram set pin to be loose and allowing excessive movement in on deck steering system. Replace set pin with proper diameter pin. 46 CFR 143.205
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 12 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 December 2025 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed a loose connection on the negative battery terminal of the starboard generator battery. 46 CFR 143.400(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 12 December 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 September 2025 Resolved
Vessel rep informed CG that vessel will not be ready or able to schedule and/or complete an annual inspection prior to 27SEPT2025, which is 3 months after COI anniversary date.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 July 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 October 2024 Resolved
No visual and audible bilge alarm indication at operating station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Bilge alarm audible/visual indicators present at operating station during test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2024 Resolved
Bilge piping holes and patched in numerous locations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Bilge piping renewed with hose and satisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 October 2024 Resolved
Excessive oil in engine room bilge and on deck plates.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Bilge emptied to satisfactory level.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 October 2024 Resolved
Fuel leak on starbard generator fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Fuel filter properly tightened and proved to be leak free during operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2024 Resolved
Starboard main engine mount shims dislodged.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Engine mount properly adjusted and shimmed to no longer be free floating.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2024 Resolved
Floating electronic marker lights found inoperable with incorrect batteries installed in both.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Light batteries replaced with approved type and tested sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 October 2024 Resolved
Towing vessel record not maintained for previous voyages. Vessel is required to submit logs for inspection after 30 days of operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 8 October 2024
Resolution: Vessel reinstated proper log techniques.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 October 2024 Resolved
Main engine gauges need to be mounted in plain sight in one location for each engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 8 October 2024
Resolution: Gauges have been repositioned to be viewable at engine local operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 October 2024 Resolved
All electrical connections in pilot house console must lead to a junction box/s.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 8 October 2024
Resolution: Junction boxes properly installed to contain wire connections in pilot house console.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 October 2024 Resolved
Starboard main engine oil pressure gauge and port generator tachometer inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 8 October 2024
Resolution: All engine gauges and tachometers are operating properly at this time.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 October 2024 Resolved
Engine room lighting secured with zip ties and must be permanently mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 8 October 2024
Resolution: Engine room lighting wiring is now properly mounted with banding.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2024 Resolved
40-B fire extinguisher at flammable storage locker past its annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2024
Resolved 8 October 2024
Resolution: Vsl provided updated annual inspection for deficient fire extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 October 2024 Resolved
Clothing dryer blocking aft engine room egress.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2024
Resolved 8 October 2024
Resolution: Vsl moved and properly mounted clothes dryer to no longer be blocking egress routes.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 October 2024 Resolved
Machinery guard on both main engine rotating machinery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 8 October 2024
Resolution: All propulsion rotating machinery (shafts and pulleys) is adequately guarded to prevent entanglement.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 September 2023 Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. MI identified radio would not turn on when vessel had no power. Install battery backup for VHF-FM radio on bridge to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2023
Resolution: MI verified proper operation of radio on battery power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MI discovered fuel leaking from discharge transfer pump piping. Renew piping to the satisfaction of the MI.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2023
Resolution: MI verified proper seal repair of transfer pump.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2023 Resolved
Flammable and combustible products must not be stored in machinery space, unless they are stored in a suitable container that meets the requirements of 142.225 of this subchapter. MI observed oil and rags not in containers in engine room. Remove oil and rags from engine room to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2023
Resolution: MI verified all rags and proper housekeeping of engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2023 Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection. MI identified fire extinguisher above engine room with no charge. Replace/service fire extinguisher with proper charge to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2023
Resolution: MI verified replacement of fire extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI discovered missing blanks on electrical panel in galley. Add blanks to panel in galley to the satisfaction of the MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2023
Resolution: Received, reviewed, and accepted photographs to clear deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 September 2023 Resolved
Emergency lighting must be provided for all internal crew working and living areas. MI observed emergency lighting in galley inoperable. Renew emergency lighting in galley to operate as required to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2023
Resolution: MI verified replacement of emergencey lighting in galley.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 September 2023 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Port side lifebouy light was not operating. Renew light to the satisfaction of the Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2023
Resolution: MI verified proper operation of life ring light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 September 2023 Resolved
All new equipment and installations must meet the applicable requirements in this part for new vessels. MI observed improper bracket for extinguisher on bridge. Affix proper bracket with proper fire extinguisher to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2023
Resolution: Received, reviewed, and accepted photographs to clear deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 September 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. MI discovered edge of port door on bridge was deteriorating. Renew metal on edge to the satisfaction of the MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2023
Resolution: Received, reviewed, and accepted photographs to clear deficiency
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2023 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi portable fire extinguisher behind pilothouse was not secured. Secure extinguisher to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2023
Resolution: Received, reviewed, and accepted photographs to clear deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Wire nuts on bridge need to be secured in a manner they will not vibrate loose. Dead end wires behind pilot house need to be removed or secured. Outlet on bridge not secured. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. 46 CFR 143.205 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 June 2022 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Anchor light is extinguished. 46 CFR 140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 20 August 2022
Resolution: Received satisfactory photo documentation from Rep.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 27 June 2022 Resolved
Where systems installed on vessels for wash water, as defined in § 1250.3(n), do not comply with the requirements of a potable water system, prescribed in § 1250.82, they shall be constructed so as to minimize the possibility of the water therein being contaminated. The storage tanks shall comply with the requirements of § 1250.83, and the distribution system shall not be cross connected to a system carrying water of a lower sanitary quality. All faucets shall be labeled “Unfit for drinking”. Apply labeling and update health and safety plan. 21 CFR 1250.87
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Conduct drills and log in TVR log book 46 CFR 140.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 27 June 2022 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. Update log book with all minimum requirements. 46 CFR 140.635
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022 Resolved
All crewmembers must be provided with health and safety information and training that includes: No means of lock out/Tag out on board vessel. 46 CFR 140.515 (a)(9)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 June 2022 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. Vessel does not have a maintenance plan. 46 CFR 143.255
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 10 January 2023
Resolution: Received satisfactory documentation/photos from vessel Rep.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 27 June 2022 Resolved
All alcohol testing devices used to meet the requirements of this part must be currently listed on either the Conforming Products List (CPL) titled “Modal Specifications for Devices To Measure Breath Alcohol” or “Conforming Products List of Screening Devices To Measure Alcohol in Bodily Fluids,” which are published periodically in the Federal Register by National Highway Traffic Safety Administration (NHTSA). Incorrect test was on vessel. 46 CFR 4.06-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 27 June 2022 Resolved
(1) A manned U.S. ship (other than a fixed or floating drilling rig or other platform) that is 26 feet or more in length; (2) A manned floating drilling rig or other platform in transit that is subject to the jurisdiction of the United States; or (3) A manned ship of 40 feet or more in length that is operated under the authority of a country other than the United States while in the navigable waters or the Exclusive Economic Zone of the United States. Vessel did not have garbage placard displayed on board. 33 CFR 151.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2022 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM; (2) Main engine cooling water temperature; (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM; (4) Auxiliary generator engine cooling water temperature; and (5) Hydraulic steering fluid pressure, if the vessel is equipped with hydraulic steering systems. Engines and generators are missing required gauges. 46 CFR 143.230 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port MDE oil and Stbd MDE JW gauges at operating station were inoperable. Oil leak on port MDE. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2022 Resolved
The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. The Marine Inspector (MI) observed there was significant wastage of the metal on both forward winches. Repair or replace in kind. 46 CFR 140.801(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022 Resolved
The hose must be a lined commercial fire hose...and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. The MI observed the chain which keeps the nozzles stream control attachment connected to the unit was missing. 46 CFR 142.325 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 June 2022 Resolved
An existing vessel may be deemed by the OCMI to be in compliance provided that the vessel has been in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questing by the OCMI. The MI observed wastage around the watertight seal of the starboard side window. Repair in kind. 46 CFR 144.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation and safety of persons onboard. The MI observed the starboard generator's windings need to be cleaned. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation and safety of persons onboard. The MI observed the unfired pressure vessel has a gauge that is cracked and has a range that exceeds 2 to 2.4 times the MAWP. Replace gauge. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation and safety of persons onboard. The MI observed the washing machine in the machinery space was not secured or strapped in place to prevent movement. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2022 Resolved
Alternate arrangements or equipment to comply with this part may be approved in accordance with 136.115 of the subchapter. The MI observed the paint locker was not properly sealed and is of an aluminum type. Please discontinue use as a paint locker or provide repair and provide a request for alternate arrangement consideration. 46 CFR 142.210(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 June 2022 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. The MI observed the enclosure for the electrical outlet above the galley sink in not functioning as designed. Repair or replace in kind. 46 CFR 143.400(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 June 2022 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly. The galley access door does not seal properly. Repair or replace in kind. 46 CFR 140.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit. The MI observed there are expired items in the first aid kit. Make sure all items are not expired. 46 CFR 140.435
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2022 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing. The MI observed wastage at the lowest elbow of the ventilation into the machinery space. Repair or replace to ensure functioning as designed. 46 CFR 144.605
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation and safety of persons onboard. The MI observed the pressure relief valve on the water heater is not piped to the bilge to protect crewmembers. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation and safety of persons onboard. The MI observed the latch to secure the oven door was missing. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory documentation/photos from vessel Rep.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 27 June 2022 Resolved
Where systems installed on vessels for wash water, as defined in § 1250.3(n), do not comply with the requirements of a potable water system, prescribed in § 1250.82, they shall be constructed so as to minimize the possibility of the water therein being contaminated. The MI observed there were no bug screens over the wash water vents. 21 CFR 1250.87
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 18 August 2022
Resolution: Received satisfactory photo documentation from vessel Rep.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2020 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date the action for this deficiency shall be changed to a 60(Rectify deficiencies prior to movement) and they vessel may no longer be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Due 3 December 2020
Resolved 10 January 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 August 2020 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and ensure the following: All bilge and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Marine inspectors found diesel, oil and water along with wood deck plates in the engine room. Remove, clean and properly dispose of water and oils in the bilge and replace wood floors with appropriate material.
Action required: 30 - Ship detained
Resolved 26 March 2021
Resolution: The owner replaced all wooden deck plates with diamond plate steel deck plates throughout the engine room. Bilges were cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2020 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Vessel had open wiring under the the cabinets, engine room and throughout the vessel. Remove or properly cap all lose wire to the satisfaction of the Marine Inspector.
Action required: 30 - Ship detained
Resolved 10 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020 Resolved
Piping and machinery components that exceed 220 Celsius including fitting, flanges, valves exhaust manifolds and turbochargers must be insulated. Marine Inspectors found severe degradation on the exhaust stack.
Action required: 30 - Ship detained
Resolved 26 March 2021
Resolution: The owner replaced all lagging on all exhaust systems.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2020 Resolved
Each towing vessel must carry at least one appropriately sized life jacket, for each person on board... Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked. Vessel is required to properly mark, label and provide proper attachments to the satisfaction of the Marine Inspector.
Action required: 30 - Ship detained
Resolved 26 March 2021
Resolution: The owner placed new lifejackets with proper attachments in service and labeled stowage locations.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 August 2020 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to propulsion engine or generator prime mover. Vessels fuel shut off valve was not permantly affixed to deck and could not be found by Marine inspectors directly outside the tank. Properly attach fuel shut off for remote operation along with directly outside the tank.
Action required: 30 - Ship detained
Resolved 26 March 2021
Resolution: The owner placed two fuel shut-off (port and stbd fuel line) valves immediately outside of the tank. Witnessed satisfactory test of the valves and verified proper marking.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 August 2020 Resolved
The master must ensure that all hatches, doors, and other opening designed to be wateright or weathertight function properly. Vessels aft door was missing gasket material. Replace gasket for door and verify proper seal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 March 2021
Resolution: Vessels aft door was gasket material was replaced. Verified door makes proper seal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2020 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life property and environment. Vessel owner stated vessel is on a Lakes, Bays, sounds route. Vessel does not have life saving equipment, navigation equipment for the route and Marine inspectors did not complete an exam to verify key items not listed above due to no crew on board. Vessel is required to have a Coast Guard inspection prior to movement to verify major systems on the vessel and crew knowledge meets the regulations and route intended.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 January 2023

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.