Records from 2000 to 2023. Most recent: inspection, 14 November 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
14 November 2023
Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7824809
30 November 2022
COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7602082
9 November 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7348089
19 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7335834
1 December 2020
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7104414
24 September 2019
Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6819498
4 October 2017
Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6277318
27 September 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6274342
27 September 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6009351
5 October 2015
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5736299
30 September 2015
Internal Structural Exam · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5732331
15 October 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5005400
29 May 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4873235
13 January 2011
Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3926754
12 January 2009
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3392490
10 October 2007
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3077140
5 March 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2882808
9 February 2007
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2870636
8 December 2005
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2548133
23 November 2005
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2539713
27 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2523299
17 October 2005
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2512519
10 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2513612
10 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2513880
26 November 2002
Hull Examination · Administrative Inspection · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1698544
9 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771383
8 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 191363
16 April 2001
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1433834
7 March 2000
Plan Review "T" Boat · COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1457746
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 November 2022
Resolved
The lights prescribed in these Rules shall have an intensity as specified in Annex I to these Rules, so as to be visible at the following minimum ranges:
(c) In a vessel of less than 12 meters in length:
(iii) A sidelight, 1 mile
Red sidelight (port) was not illuminating during inspection. Prove proper operation prior to operating at
night.
33 CFR 83.22(c)(iii)
Action required: 705 - Other - as specified
Resolved 7 February 2023
Resolution: New light installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 November 2022
Resolved
The manning requirements for a particular vessel are determined by the OCMI after consideration of the applicable laws, the regulations in this part, and all other factors involved, such as: emergency situations, size and type of vessel, installed equipment, use of labor saving devices, and the organizational structure
of the vessel.
Vessel required to to be manned with one Deckhand in addition to Master when carrying more than six passengers. Amended COI to be provided with adjusted
manning requirement.
46 CFR 15.501 (b)
Action required: 705 - Other - as specified
Resolved 28 February 2023
Resolution: Manning requirement updated to include 01 deckhand.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 November 2022
Resolved
Remote fuel shutoff station shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation.
Fuel supply valve on the weather deck was not labelled.
46 CFR 185.30-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 7 February 2023
Resolution: Supply valve labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 November 2022
Resolved
Openings through which conductors enter shall be adequately closed.
Generator windings enclosure was sealed with duct tape rather than sealed with its corresponding hardware.
46 CFR 111.75-35(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 7 February 2023
Resolution: Duct tape removed from cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2022
Resolved
Fill and sounding pipes shall be fitted with shutoff valves, watertight deck plates or screw caps suitably marked for identification.
Fill valve was not labelled.
46 CFR 182.20-30(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 7 February 2023
Resolution: Valve labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2022
Resolved
A suitable hull strainer shall be installed in the circulating water intake line.
Incorrect gasket was placed on strainer.
46 CFR 182.20 (b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 7 February 2023
Resolution: Correct gasket installed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 November 2022
Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe.
Starboard MDE had an exposed exhaust pipe with no protection to personnel.
46 CFR 182.20-20
Ref. 46 CFR 182.15-20(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 7 February 2023
Resolution: Pipe temp tested and does not get hot enough to require covering. Water cooled pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 November 2021
Resolved
All distribution panels shall be dripproof protected, and so constructed or protected that its successful operation is not interfered with when subject to falling moisture or dirt.
Marine Inspector observed engine room distribution panel front cover not secured to panel box. Also, door of panel box was missing.
Secure front cover to the panel box and re install fron panel box door to the satisfaction of a US Coast Guard Marine Inspector.
46 CFR 183.10-10(a)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 28 November 2021
Resolution: Front cover replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2021
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets, with an attached lanyard.
Marine Inspector observed one fire bucket lanyard not attached to fir bucket.
Attach lanyard to fire bucket to the satisfaction of a US Coast Guard Marine Inspector.
46 CFR 181.610
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 28 November 2021
Resolution: Lanyard attatched to fire bucket. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 October 2021
Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends and elbows. It shall be gas tight throughout its length.
Marine inspector found a half inch hole in generator exhaust pipe running through aft steering.
Remove and replace exhaust pipe to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 182.15-20(a)
17 C
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 10 February 2022
Resolution: Exhaust pipe replaced. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2021
Resolved
Where exhaust piping passes through watertight bulkheads, the watertight integrity of the bulkhead shall be maintained.
Marine Inspector found hole in exhaust piping seal from aft steering passing through watertight bulkhead to engine room.
Seal watertight bulkhead around exhaust piping penetration to the satisfaction of a Coast Guard Inspector.
46 CFR 182.15-20(d)
17 C
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 10 February 2022
Resolution: Exhaust pipe pass thru sealed. All sat.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 October 2021
Resolved
A screw down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions.
Marine Inspector found fore peak screw down valve on aft side of collision bulkhead not readily accessible to crew during emergency.
Clear excess gear away from screw down valve and make readily accessible.
46 CFR 182.25-5(d)
701 C
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 10 February 2022
Resolution: Gear removed. Valve accessable. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 October 2021
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel.
Marine Inspector found a one inch crack on starboard aft rub rail.
Prepare location and repair crack to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 177.10(a)
701 C
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2021
Resolved 10 February 2022
Resolution: Crack repaired. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. Vessel's fuel shutoff was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2019
Resolution: Shutoff valve was repositioned and is working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2019
Resolved
Vessel must be provided with bilge pumps in accordance with Table 182.520 (a). Vessel's bilge
pump was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2019
Resolution: Bilge pump was operable.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2019
Resolved
Vessel not required to have a power driven fire pump must have at least three (2 1/2 gallon) buckets with an attached lanyard and labeled "Fire Bucket". Buckets must be easily available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2019
Resolution: Fire buckets were onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 September 2019
Resolved
Owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fixed fire extinguishing system had not been serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2019
Resolution: Fixed fire extinguishing system was serviced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2019
Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and general description of the drill scenario and training topics. The prior months to the inspection did not have drills logged. Drills will be conducted again to the satisfaction of the attending Marine Inspector prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 17 October 2019
Resolution: Drills were being logged and an sign was posted to remind the Captain to perform drills.
Fire Fighting › Fire Pumps › Capacity
Issued 5 October 2015
Resolved
Provide operating fire pump onboard prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2015
Resolved 9 October 2015
Resolution: Provided
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 October 2015
Resolved
Conduct fire and man overboard drills to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 9 October 2015
Resolution: Conducted fire drill.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 October 2015
Resolved
Adjust starboard shaft packing.
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 9 October 2015
Resolution: Adjusted shaft packing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 October 2015
Resolved
Provide current CO2 servicing.
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 9 October 2015
Resolution: Provided.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 5 October 2015
Resolved
Provide attachment for forward hatch.
Due 19 October 2015
Resolved 9 October 2015
Resolution: Provided attachment.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 October 2015
Resolved
Provide donning placards for all types of lifejackets onboard.
Due 19 October 2015
Resolved 9 October 2015
Resolution: Provided placards.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 October 2015
Resolved
Stencil life ring with vessel name.
Due 19 October 2015
Resolved 9 October 2015
Resolution: Stenciled life ring.
Documentation › Certificates/Documents › Stability Letter
Issued 5 October 2015
Resolved
Post Stability letter.
Due 19 October 2015
Resolved 5 October 2015
Resolution: Stability Letter posted.
Engineering › Fuel Oil Service System › Hose
Issued 12 January 2009
Resolved
Fuel lines do not meet the requirements of 46 CFR 182.720.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 January 2009
Resolved
The water lines are not double clamped.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 January 2009
Resolved
The fixed CO2 system has not been serviced since Feb 2007.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Engineering › Bilge Water Management System › Piping
Issued 12 January 2009
Resolved
The E/R bilge alarm is located too high.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 January 2009
Resolved
There is water in the battery boxes.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Lifesaving › Lifefloat › Lifeline
Issued 12 January 2009
Resolved
The 60 ft lifeline is missisng.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Lifesaving › Lifefloat › Lifeline
Issued 12 January 2009
Resolved
The 3 ft lanyard is wasted and unservicable
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Lifesaving › Buoyant Smoke Signals › General
Issued 12 January 2009
Resolved
Vessel has no orange smoke signals.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Documentation › Logs/Records › Logbook (official)
Issued 12 January 2009
Resolved
The log of drills and training was not available for inspection.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 January 2009
Resolved
The lifejacket donning instructions are not posted.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Fire Fighting › Fire Pumps › Pressure
Issued 12 January 2009
Resolved
The fire pump could not be tested.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 January 2009
Resolved
The heat blankets were missing from the exhaust piping.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Construction/Loadline › Penetrations › Gasket
Issued 10 October 2007
Resolved
Repair the port shaft seal.
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 16 October 2007
Resolution: Repairs made.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 October 2007
Resolved
Provide lagging on the engine exhaust on the port and stbd MDE's, in the machinery space.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 16 October 2007
Resolution: Repairs made.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 March 2007
Resolved
Install a fire detection system in the machinery space that the circuit is electrically supervised as per 46 CFR 181.400(c). The installed smoke detection system must be tested by the operator every 14 days and logged in the ships log. If the system is found to be inoperative it must be repaired prior to operating the vessel and the local USCG OCMI notified.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 11 June 2007
Resolution: System Installed.
Construction/Loadline › Structures › Manhole
Issued 9 February 2007
Resolved
Repair broken fwd scuttle hatch.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 9 February 2007
Resolved
Install machinery guard on port engine.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Communications › Public Address System › Broadcast Location
Issued 9 February 2007
Resolved
Install emergency broadcast placard.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 9 February 2007
Resolved
Double clap all hoses on both main diesel engines.
Due 9 March 2007
Resolved 9 March 2007
Resolution: Item corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 February 2007
Resolved
Install lagging on both engine's exhuast piping.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 February 2007
Resolved
Service fixed fire fighting in engine room.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 February 2007
Resolved
Service all portable fire extinguishers.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 9 February 2007
Resolved
Replace outdated charts.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 February 2007
Resolved
Replace outdated Coast Guard light list.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 February 2007
Resolved
Replace outdated tide/tidal current table.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 February 2007
Resolved
Replace US Coast pilot.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 February 2007
Resolved
Replace first aid kit.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Personnel › Training › First Aid/CPR
Issued 9 February 2007
Resolved
Vessel captain's CPR card has expired.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 February 2007
Resolved
Repair bilge alarm in aft steering compartment.
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 October 2005
Resolved
Repair or replace holed battery box in the machinery space.
Due 17 November 2005
Resolved 18 November 2005
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 17 October 2005
Resolved
Renew the hose on starboard keel cooler freshwater inlet.
Due 17 November 2005
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 17 October 2005
Resolved
Provide guard covers for all lights in the passenger cabin.
Due 17 November 2005
Resolved 18 November 2005
Construction/Loadline › Penetrations › Gasket
Issued 17 October 2005
Resolved
Renew port cutlass bearing.
Due 17 November 2005
Resolved 18 November 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 October 2005
Resolved
Prior to operating the vessel complete credit drydock, Internal structural and Annual inspections.
Due 21 October 2005
Resolved 17 October 2005
Resolution: Exam completed.
Construction/Loadline › Hull
Issued 5 November 2002
Resolved
Hull plating around prop wash area pitted. Will required closer examination after the sand blasting of the vessel's hull. Issued CG-835 for closer examination of the pitted area after blasting and prior to recoating the hull to be completed NLT 05Dec02. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 21 November 2002
Resolution: Inspected the pitting area after sand blasting, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 November 2002
Resolved
Issued CG-835 item #2 for annual servicing of fixed CO2 system and provide servicing certificate to USCG NLT 05Dec02. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 21 November 2002
Resolution: Fixed fire extinguisher servicing certificate was provided, all sat.
Fire Fighting
Issued 7 March 2000
Resolved
Provide details and drawings of fixed extinguishing system per item 16 of 03MAR00 letter. Details in MINS.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Electrical
Issued 7 March 2000
Resolved
Provide additional information for electrical plans as stated in item 20 of03MAR00 letter. See MINS for details.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 7 March 2000
Resolved
Send payment for user fee per 46 CFR 2.10-101.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 7 March 2000
Resolved
Provide evidence that furniture and furnishings meet the requirments of 46 CFR 116.423.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Construction/Loadline
Issued 7 March 2000
Resolved
Provide means to secure engine room hatches per 46CFR179.360(b)(1).
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 7 March 2000
Resolved
Describe means to comply with secondary means of escape in passenger space and provide markings and equipmnt for said means of escape.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000