Records from 1992 to 2017. Most recent: inspection, 20 January 2017.
Documentation record
Registered dimensions (L × B × D)47.2 ft × 19.2 ft × 5.5 ft
Registered tonnagegross 44 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINLAND RIVERS CORP · JOLIET, IL, UNITED STATES · built 1982
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
30 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 36
20 January 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6081140
15 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5980132
23 June 2016
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5981111
15 June 2014
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5014953
6 February 2013
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4529338
30 January 2013
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4529114
30 January 2013
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4529208
8 November 2012
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4480999
24 August 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4424542
3 March 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3956579
11 January 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3924798
11 January 2011
Examination of Repairs · Marine Casualty Follow Up · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3924802
1 March 2010
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3687973
12 November 2009
Industry Initiated Exam · MTSA Verification · MARPOL
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3635363
26 March 2009
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3440398
16 January 2009
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3395524
28 August 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3050504
10 August 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3055848
17 March 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2892914
13 October 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2800105
10 August 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2742867
10 August 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2742910
1 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2593901
23 January 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2574379
21 December 2005
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2564343
8 December 2005
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2555289
26 May 2005
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2369108
3 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979286
24 September 2003
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1913656
23 January 2001
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 484880
5 October 1999
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 433698
13 July 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 418082
22 October 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 409205
20 October 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 409110
11 October 1995
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 383871
30 August 1992
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 96314
Fire Fighting › Fixed Fire Detection System › Approval
Issued 21 December 2005
Resolved
Provide proof fire detection system is certified by a licensed professional engineer or classification society as required under 46 CFR 27.203 (g)
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 21 February 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 December 2005
Resolved
Fire Extingushers not in approved brackets as required under 46 CFR 25.30-5
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2006
Resolved 23 January 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 December 2005
Resolved
Need updated Coast Guard light list as required under 33 CFR 164.72(b)(2)
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2006
Resolved 23 January 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 December 2005
Resolved
magnetic compass not illuminated as required under 33 CFR 164.72(a)(4)
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2006
Resolved 23 January 2006
Lifesaving
Issued 5 October 1999
Resolved
GRAB LINES ON 2 LIFE RINGS DETERIORATED.
Condition: Unknown
Due 6 October 1999
Resolved 13 October 1999
Lifesaving
Issued 5 October 1999
Resolved
AIR COMPRESSOR NOT EQUIPED WITH RELIEF VALVE.
Condition: Unknown
Due 6 October 1999
Resolved 13 October 1999
Fire Fighting
Issued 5 October 1999
Resolved
FIRE EXTINGUISHER IN GALLEY NOT PROPERLY MOUNTED.
Condition: Unknown
Due 6 October 1999
Resolved 13 October 1999