← All vessels
LITTLE DEEPER
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named LITTLE DEEPER
LITTLE DEEPER is a 1982 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2001, most recently in February 2026, along with 77 deficiencies and 2 casualty investigations between 2010 and 2011.
Records from 2001 to 2026. Most recent: inspection, 26 February 2026.
- Built
- 1982
- Last inspected
- 26 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 77 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2010–2011
Identity
647440
WDD5021
206705
Flag
UNITED STATES
367152550
Maury page id
psix-206705
Inspections, by type
…with no type recorded2
Years with a record
23 calendar years (2001–2026)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)38.0 ft × 12.8 ft × 4.2 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL, FL, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWEST PALM BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD5021MMSI 367152550 · active · compulsorily equipped · granted 9 November 2016, expires 25 November 2026
WDA3587MMSI 366800010 · expired · voluntarily equipped · granted 8 February 2001, cancelled 16 April 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 39
26 February 2026
Internal Structural Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8317574
24 December 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8287126
22 May 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8141728
23 April 2024
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7908251
13 February 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7865354
20 November 2023
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7827199
17 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7652766
22 February 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7393648
20 January 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7391383
21 May 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7202840
15 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6953965
27 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6937531
22 May 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6702149
9 May 2018
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6410539
20 February 2018
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6357961
22 February 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6092468
27 September 2016
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6010341
31 May 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5893510
22 March 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5842154
2 October 2015
Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5734015
4 January 2012
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4218535
29 August 2011
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4127558
16 September 2010
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3851119
11 March 2009
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3431718
10 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3430805
14 March 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3164362
20 June 2007
Simplified Stability Test · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2976622
21 February 2007
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2874449
11 January 2007
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2842163
12 July 2005
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2423746
28 February 2005
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2299172
18 October 2004
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2223054
8 July 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2125748
26 June 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1827180
26 February 2003
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1749115
25 February 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1488802
30 May 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1070531
20 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440441
12 February 2001
Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1058046
Deficiency record · 77
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 May 2025
Resolved
Each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons on board. Life float was found unfit for service. Vessel is restricted to within three miles of land.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 May 2025
Resolved
Each life float must be fitted with two paddles. One life float paddle was broke the other is severely cracked. Both need replacing.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2025
Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station. Aft compartment and engine-room visual indicator are inoperable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicators for all three pumps are inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2025
Resolved
A vessel not required to have a power driven fire pump, must have at least three, 2.5 gallon buckets, with an attached lanyard. One of the buckets is missing a lanyard. Stencil on all three buckets is faded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 May 2025
Resolved
A hatch exposed to the weather must be watertight. Engine-room hatches and laz hatch have broken coaming making them weathertight not watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2025
Resolved
A vessel on a limited coastwise route must carry six red flare distress signals and six orange smoke distress signals. Vessel had eight expired flares on board. Owner was able to procure flares after completion of inspection. Cleared 22MAY25.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket was found unfit for service. Owner was able to procure life jacket after completion of inspection. Cleared 22MAY25.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2025
Resolved
To enhance protection of life and property it is mandatory that each EPIRB be registered with NOAA. Registration on board expired. Vessel owner was able to produce up-to-date registration after completion of inspection. Cleared 22MAY25.
47 CFR 80.1061
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2024
Resolved
46 CFR 16.401 The employer shall provide EAP for all crew members. There is no evidence of a EAP program in place, no evidence of supervisory personnel receiving 60 min of training, no evidence of crew training and no displayed documentation listing the EAP program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2024
Resolved
46 CFR 16.201 (a) Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Marine employer could not produce a valid company random drug testing program or a valid contract that the company is part of a CG approved consortium.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicators would not illuminate when actiavted in the autmoatic position.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 May 2024
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel always leaves port and at all times while underway. Life float is showing exterior material cracking , retro reflective tape is non functional. Repair or replace in accordance with manufacturers recommendations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 May 2024
Resolved
Each life ring on a vessel must be approved in accordance with 160.050 in Subchapter Q of this chapter. Ring buoy’s grab line supports were separated, retro tape was wasted.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 May 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel with terms of its COI giving consideration to provision for a seaworthy hull and protection against fire. STBD side outboard E/R compartment under deck wood framing in engine room is severely angel haring and breaking down creating a combustible hazard. Remove angel hair on affected wood.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 May 2023
Resolved
Each rescue boat and ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retro tape weathered and non-reflective replace with new.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 May 2023
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel always leaves port and at all times while underway. Life float is showing exterior material cracking , retro reflective tape is non functional and some grab line supports are torn. Repair or replace in accordance with manufacturers recommendations.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 May 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instructions were not present on the bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump if it is supplied by a source of power independent of the first power bilge pump. Vessel is only required 01 fixed power bilge pumps and 01 portable hand pump. Vessel is missing its portable hand pump.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 18 May 2023
Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB test were not being logged. Discussed and corrected on the spot.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 May 2023
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill shall include the following information, (1) Date of the drill and training; and (2) General description of the drill
scenario. Discussed and corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 February 2022
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
The Engine RPM gauge was non operational at the time of the inspection. Corrected on the spot, a loose wire on the alternator was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2022
Resolved
Replace the gusset for the racor supports prior to credit dry-dock. 46 CFR 176.610
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 January 2022
Resolved
Some superficial damage was noted above the chine on both sides of the vessel with active ongoing repairs being conducted. Repair in-kind as discussed prior to credit dry-dock. 46 CFR 176.610
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022
Resolved
Replace cutlass bearings prior to credit dry-dock. 46 CFR 176.610
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2021
Resolved
In a vessel of less than 12 meters in length:
(iii) A sternlight, 2 mile.
Sternlight was found not working. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 May 2021
Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition.
The retro reflective Solas tape was found worn and several areas on the top of the float have excessive UV damage. Repair/ replace as discussed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy and must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 50 pounds, and allow the waterlight to be quickly disconnected from the ring life buoy.
The lanyard was found deteriorated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 May 2021
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned spaces.
The Aft bilge alarm, at the panel, has excessive corrosion on it (self reported). Repair/ replace as discussed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
The vessel must be issued n FCC Station License for any of the following if installed on the vessel: Radiotelephones, Radars, EPIRB.
Proof was shown that the vessel is in compliance but the certificate was not on board. Contact FCC to receive the certificate. 47CFR80.13
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 May 2019
Resolved
Renew expired EPIRB battery and HRU, vessel limited to NMT 3 NM from shore until rectified.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2019
Resolved
Renew extinguished stern light bulb and raise all-around light to above the bimini top.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 May 2018
Resolved
Register EPIRB
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2018
Resolved
Remove negative battery cable
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2018
Resolved
Re-connect bonding wires in E/R
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 May 2018
Resolved
Mark emergency fuel S/O
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 May 2018
Resolved
Demonstrate operation of waterlight on lifefloat
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 February 2017
Resolved
Provide logbook for logging emergency drills.
Documentation › Certificates/Documents › FCC SSL
Issued 22 February 2017
Resolved
Provide current FCC SSL
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2017
Resolved
Use or remove loose wire under console.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 February 2017
Resolved
Install new retro tape on ring buoy.
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 February 2017
Resolved
Install new retro tape on lifefloat.
Communications › Radio Communications › EPIRB
Issued 22 February 2017
Resolved
Provide new hydrostatic release for Epirb, expires the end of March.
Engineering › Bilge Water Management System › Pump
Issued 27 September 2016
Resolved
Prove proper operation of bilge pump in fwd compt.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2016
Resolved
Remove dead end wire in fwd compt.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 27 September 2016
Resolved
Re-attach all loose bonding wire in the engine room and lazerette.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 September 2016
Resolved
Seal fwd and aft engine room bulkheads.
Stability › Watertight Integrity › General
Issued 27 September 2016
Resolved
Renew hatch gaskets.
Stability › Watertight Integrity › General
Issued 27 September 2016
Resolved
Renew broken hatch latches for the STBD side engine room hatch.
Operations/Management › Vessel Activity › Construction/Repair
Issued 2 October 2015
Resolved
Owner completed STBD engine change out without notification to the CG.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 March 2008
Resolved
Prove proper operation of engine shut down on the fixed fire fighting system.
Lifesaving › Lifefloat › Paddle
Issued 14 March 2008
Resolved
Provide 4 foot paddles for life float with proper markings.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 March 2008
Resolved
Provide 18 foot painter line for the floating water light.
Engineering › Fuel Oil Service System › Valve
Issued 14 March 2008
Resolved
Provide new handles for the valves a the fuel tank.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 21 February 2007
Resolved
Anchor Winch not operating, due to electrical problems. VSL is capable lowing Anchor at this time.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 21 February 2007
Resolved
Anchor Shackle does not have safety wire (Mousing).
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 21 February 2007
Resolved
Steering Gear Bonding/Ground cables not properly connected.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 February 2007
Resolved
VSL master does not have Employee Assistance Program training for supervisors.
Engineering › Bilge Water Management System › Pump
Issued 21 February 2007
Resolved
VSL could not prove the proper operation of Bilge Pumps.
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2007
Resolved
Make proper repairs to area of lower hull starboard side and provide photo documentation of repairs.
Construction/Loadline › Hull › Side Shell
Issued 11 January 2007
Resolved
Properly repair delamination under bench port side lower cabin.
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2007
Resolved
Complete two outstanding dry dock items from 2005.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 28 February 2005
Resolved
Seal all openings in aft engine room bulkhead.
Construction/Loadline › Structures › Plowshare Breakwater
Issued 28 February 2005
Resolved
Make proper repairs to crack on port plowshare breakwater
Construction/Loadline › Hull › Strut/Cross Tie
Issued 28 February 2005
Resolved
Secure deck post in port aft lazzertte
Construction/Loadline › Structures › Manhole
Issued 28 February 2005
Resolved
Properly repair escape hatch on forward bow.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 July 2004
Resolved
Provide new hydrostatic release and an antenna for EPRIB prior to carrying passengers.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 8 July 2004
Resolved
Make permanent and proper repairs to the aft in board engine mount on the Stbd main engine NLT 08/01/04
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 July 2004
Resolved
Make Permanent and proper repairs to the outboard exhaust hose on the stbd main engine NLT 08/01/04
Engineering › Lubricating Oil Service System › Hose
Issued 8 July 2004
Resolved
Replace hose fitting on the oil changing hose stbd main engine
Communications › Radio Communications › VHF Radiotelephone
Issued 8 July 2004
Resolved
Prove proper operation of the VHF Radio prior to carrying passengers.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 July 2004
Resolved
Prove proper operation of the smoke detection system and prove system is still install in accordance with approve plans, (forward detector missing?)
Navigation › Piloting/Steering
Issued 25 February 2002
Resolved
Provide all current nav pubs and charts. LEGACY COMPONENT DESC: Navigational Publications and Charts
Communications › Radio Communications
Issued 12 February 2002
Resolved
Provide FCC Ship Safety Certificate. LEGACY COMPONENT DESC: FCC Safety Certificate
Documentation
Issued 12 February 2001
Resolved
PROVIDE A VALID FCC STATION LICENSE AND SAFETY RADIO CERTIFICATE. VESSEL IS RESTRICTED TO OPERATIONS WITHIN 1000 FEET FROM SHORE.
Unknown
Issued 12 February 2001
Resolved
PRIOR TO OPERATION WITH PASSENGERS, MAKE VESSEL AVAILABLE FOR INSPECTION BYCOGNIZANT [name withheld] ITEMS ISSUED BY PTCD 08FEB01.
Electrical
Issued 12 February 2001
Resolved
PROVIDE COPY OF CG APPROVED ELECTRICAL PLANS IN ACCORDANCE WITH 46 CFR 177.202.
Casualty record · 2
14 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3716616
24 March 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3971741
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.