MAURY USCG vessel records Sign in
← All vessels

LITTLE DEEPER

LITTLE DEEPER is a 1982 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2001, most recently in February 2026, along with 77 deficiencies and 2 casualty investigations between 2010 and 2011.

Records from 2001 to 2026. Most recent: inspection, 26 February 2026.

Built
1982
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5021
206705
Flag
UNITED STATES
367152550
Maury page id
psix-206705

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (2001–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 12.8 ft × 4.2 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL, FL, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWEST PALM BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD5021MMSI 367152550 · active · compulsorily equipped · granted 9 November 2016, expires 25 November 2026
WDA3587MMSI 366800010 · expired · voluntarily equipped · granted 8 February 2001, cancelled 16 April 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

26 February 2026 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8317574
24 December 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8287126
22 May 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8141728
23 April 2024 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7908251
13 February 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7865354
20 November 2023 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7827199
17 May 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7652766
22 February 2022 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7393648
20 January 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7391383
21 May 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7202840
15 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6953965
27 February 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6937531
22 May 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6702149
9 May 2018 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6410539
20 February 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6357961
22 February 2017 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6092468
27 September 2016 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6010341
31 May 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5893510
22 March 2016 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5842154
2 October 2015 Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5734015
4 January 2012 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4218535
29 August 2011 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4127558
16 September 2010 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3851119
11 March 2009 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3431718
10 March 2009 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3430805
14 March 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3164362
20 June 2007 Simplified Stability Test · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2976622
21 February 2007 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2874449
11 January 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2842163
12 July 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2423746
28 February 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2299172
18 October 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2223054
8 July 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2125748
26 June 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1827180
26 February 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1749115
25 February 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1488802
30 May 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1070531
20 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440441
12 February 2001 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1058046

Deficiency record · 77

11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 May 2025 Resolved
Each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons on board. Life float was found unfit for service. Vessel is restricted to within three miles of land.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 December 2025
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 May 2025 Resolved
Each life float must be fitted with two paddles. One life float paddle was broke the other is severely cracked. Both need replacing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2025
Resolution: Provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2025 Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station. Aft compartment and engine-room visual indicator are inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: Repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicators for all three pumps are inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2025 Resolved
A vessel not required to have a power driven fire pump, must have at least three, 2.5 gallon buckets, with an attached lanyard. One of the buckets is missing a lanyard. Stencil on all three buckets is faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 May 2025 Resolved
A hatch exposed to the weather must be watertight. Engine-room hatches and laz hatch have broken coaming making them weathertight not watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2025
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2025 Resolved
A vessel on a limited coastwise route must carry six red flare distress signals and six orange smoke distress signals. Vessel had eight expired flares on board. Owner was able to procure flares after completion of inspection. Cleared 22MAY25.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket was found unfit for service. Owner was able to procure life jacket after completion of inspection. Cleared 22MAY25.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2025 Resolved
To enhance protection of life and property it is mandatory that each EPIRB be registered with NOAA. Registration on board expired. Vessel owner was able to produce up-to-date registration after completion of inspection. Cleared 22MAY25. 47 CFR 80.1061
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2024 Resolved
46 CFR 16.401 The employer shall provide EAP for all crew members. There is no evidence of a EAP program in place, no evidence of supervisory personnel receiving 60 min of training, no evidence of crew training and no displayed documentation listing the EAP program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2024
Resolution: Evidence of compliance provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2024 Resolved
46 CFR 16.201 (a) Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Marine employer could not produce a valid company random drug testing program or a valid contract that the company is part of a CG approved consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2024
Resolution: Evidence of compliance provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicators would not illuminate when actiavted in the autmoatic position.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2024
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 May 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel always leaves port and at all times while underway. Life float is showing exterior material cracking , retro reflective tape is non functional. Repair or replace in accordance with manufacturers recommendations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2024
Resolution: Lifelfoat repaired satsifactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 May 2024 Resolved
Each life ring on a vessel must be approved in accordance with 160.050 in Subchapter Q of this chapter. Ring buoy’s grab line supports were separated, retro tape was wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2024
Resolution: New retro tape applied.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 May 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel with terms of its COI giving consideration to provision for a seaworthy hull and protection against fire. STBD side outboard E/R compartment under deck wood framing in engine room is severely angel haring and breaking down creating a combustible hazard. Remove angel hair on affected wood.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2023
Resolution: All angel hair scraped and wood protective coating applied.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 May 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retro tape weathered and non-reflective replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2023
Resolution: retro replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 May 2023 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel always leaves port and at all times while underway. Life float is showing exterior material cracking , retro reflective tape is non functional and some grab line supports are torn. Repair or replace in accordance with manufacturers recommendations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Lifefloat refurbished.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 May 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instructions were not present on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: Created emergency instructions placard and placed at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump if it is supplied by a source of power independent of the first power bilge pump. Vessel is only required 01 fixed power bilge pumps and 01 portable hand pump. Vessel is missing its portable hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: Purchased new portable hand bilge pump.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 18 May 2023 Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB test were not being logged. Discussed and corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Corrected
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 May 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill shall include the following information, (1) Date of the drill and training; and (2) General description of the drill scenario. Discussed and corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 February 2022 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The Engine RPM gauge was non operational at the time of the inspection. Corrected on the spot, a loose wire on the alternator was repaired.
Action required: 10 - Deficiency Rectified
Due 22 February 2022
Resolved 22 February 2022
Resolution: Corrected on the spot, a loose wire on the alternator was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2022 Resolved
Replace the gusset for the racor supports prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 2 February 2022
Resolution: Gusset replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 January 2022 Resolved
Some superficial damage was noted above the chine on both sides of the vessel with active ongoing repairs being conducted. Repair in-kind as discussed prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 2 February 2022
Resolution: Repairs SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022 Resolved
Replace cutlass bearings prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 2 February 2022
Resolution: Bearings replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2021 Resolved
In a vessel of less than 12 meters in length: (iii) A sternlight, 2 mile. Sternlight was found not working. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 24 May 2021
Resolved 24 May 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 May 2021 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. The retro reflective Solas tape was found worn and several areas on the top of the float have excessive UV damage. Repair/ replace as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy and must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 50 pounds, and allow the waterlight to be quickly disconnected from the ring life buoy. The lanyard was found deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 May 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned spaces. The Aft bilge alarm, at the panel, has excessive corrosion on it (self reported). Repair/ replace as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Bilge alarm was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021 Resolved
The vessel must be issued n FCC Station License for any of the following if installed on the vessel: Radiotelephones, Radars, EPIRB. Proof was shown that the vessel is in compliance but the certificate was not on board. Contact FCC to receive the certificate. 47CFR80.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2021
Resolved 7 June 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 May 2019 Resolved
Renew expired EPIRB battery and HRU, vessel limited to NMT 3 NM from shore until rectified.
Action required: 705 - Other - as specified
Due 22 June 2019
Resolved 11 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2019 Resolved
Renew extinguished stern light bulb and raise all-around light to above the bimini top.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 24 June 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 May 2018 Resolved
Register EPIRB
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2018 Resolved
Remove negative battery cable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2018 Resolved
Re-connect bonding wires in E/R
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 May 2018 Resolved
Mark emergency fuel S/O
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 May 2018 Resolved
Demonstrate operation of waterlight on lifefloat
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 February 2017 Resolved
Provide logbook for logging emergency drills.
Due 22 March 2017
Resolved 4 April 2017
Resolution: Provided log book for drills.
Documentation › Certificates/Documents › FCC SSL
Issued 22 February 2017 Resolved
Provide current FCC SSL
Due 22 March 2017
Resolved 4 April 2017
Resolution: Provided copy where new FCC SSL had been ordered.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2017 Resolved
Use or remove loose wire under console.
Due 22 March 2017
Resolved 4 April 2017
Resolution: Removed loose wire under console.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 February 2017 Resolved
Install new retro tape on ring buoy.
Due 22 March 2017
Resolved 4 April 2017
Resolution: Installed new retro tape on ring buoy.
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 February 2017 Resolved
Install new retro tape on lifefloat.
Due 22 March 2017
Resolved 4 April 2017
Resolution: Installed new retro tape on life float.
Communications › Radio Communications › EPIRB
Issued 22 February 2017 Resolved
Provide new hydrostatic release for Epirb, expires the end of March.
Due 31 March 2017
Resolved 5 April 2017
Resolution: Installed new hydrostatic release for epirb.
Engineering › Bilge Water Management System › Pump
Issued 27 September 2016 Resolved
Prove proper operation of bilge pump in fwd compt.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2016
Resolution: Installed new UL listed electric bilge pump.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2016 Resolved
Remove dead end wire in fwd compt.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2016
Resolution: Dead end wire has been removed.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 27 September 2016 Resolved
Re-attach all loose bonding wire in the engine room and lazerette.
Due 19 October 2016
Resolved 19 October 2016
Resolution: All bonding wire has been re-attached.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 September 2016 Resolved
Seal fwd and aft engine room bulkheads.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2016
Resolution: Bulkheads have been sealed.
Stability › Watertight Integrity › General
Issued 27 September 2016 Resolved
Renew hatch gaskets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2016
Resolution: All hatch gaskets have been re-newed.
Stability › Watertight Integrity › General
Issued 27 September 2016 Resolved
Renew broken hatch latches for the STBD side engine room hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2016
Resolution: Hatch latches have been replaced.
Operations/Management › Vessel Activity › Construction/Repair
Issued 2 October 2015 Resolved
Owner completed STBD engine change out without notification to the CG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2015
Resolved 2 October 2015
Resolution: Owner has changed engine with new long block. Engine identical to one removed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 March 2008 Resolved
Prove proper operation of engine shut down on the fixed fire fighting system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2008
Resolved 14 March 2008
Lifesaving › Lifefloat › Paddle
Issued 14 March 2008 Resolved
Provide 4 foot paddles for life float with proper markings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 11 March 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 March 2008 Resolved
Provide 18 foot painter line for the floating water light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 11 March 2009
Engineering › Fuel Oil Service System › Valve
Issued 14 March 2008 Resolved
Provide new handles for the valves a the fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2008
Resolved 11 March 2009
Deck/Cargo › Mooring/Anchoring › Winch
Issued 21 February 2007 Resolved
Anchor Winch not operating, due to electrical problems. VSL is capable lowing Anchor at this time.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 11 March 2009
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 21 February 2007 Resolved
Anchor Shackle does not have safety wire (Mousing).
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 27 March 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 21 February 2007 Resolved
Steering Gear Bonding/Ground cables not properly connected.
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 27 March 2007
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 February 2007 Resolved
VSL master does not have Employee Assistance Program training for supervisors.
Due 21 March 2007
Resolved 14 March 2008
Engineering › Bilge Water Management System › Pump
Issued 21 February 2007 Resolved
VSL could not prove the proper operation of Bilge Pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2007
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2007 Resolved
Make proper repairs to area of lower hull starboard side and provide photo documentation of repairs.
Action required: 705 - Other - as specified
Resolved 12 January 2007
Construction/Loadline › Hull › Side Shell
Issued 11 January 2007 Resolved
Properly repair delamination under bench port side lower cabin.
Action required: 705 - Other - as specified
Resolved 21 February 2007
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2007 Resolved
Complete two outstanding dry dock items from 2005.
Action required: 705 - Other - as specified
Resolved 21 February 2007
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 28 February 2005 Resolved
Seal all openings in aft engine room bulkhead.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 February 2007
Construction/Loadline › Structures › Plowshare Breakwater
Issued 28 February 2005 Resolved
Make proper repairs to crack on port plowshare breakwater
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 2 March 2005
Construction/Loadline › Hull › Strut/Cross Tie
Issued 28 February 2005 Resolved
Secure deck post in port aft lazzertte
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 11 January 2007
Construction/Loadline › Structures › Manhole
Issued 28 February 2005 Resolved
Properly repair escape hatch on forward bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 February 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 July 2004 Resolved
Provide new hydrostatic release and an antenna for EPRIB prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04, confirmed the vsl was not operating before this date.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 8 July 2004 Resolved
Make permanent and proper repairs to the aft in board engine mount on the Stbd main engine NLT 08/01/04
Due 1 August 2004
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04, confirmed the vsl was not operating before this date.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 July 2004 Resolved
Make Permanent and proper repairs to the outboard exhaust hose on the stbd main engine NLT 08/01/04
Due 1 August 2004
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04, confirmed the vsl was not operating before this date.
Engineering › Lubricating Oil Service System › Hose
Issued 8 July 2004 Resolved
Replace hose fitting on the oil changing hose stbd main engine
Due 1 August 2004
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04, confirmed the vsl was not operating before this date.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 July 2004 Resolved
Prove proper operation of the VHF Radio prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04, confirmed the vsl was not operating before this date.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 July 2004 Resolved
Prove proper operation of the smoke detection system and prove system is still install in accordance with approve plans, (forward detector missing?)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04, confirmed the vsl was not operating before this date.
Navigation › Piloting/Steering
Issued 25 February 2002 Resolved
Provide all current nav pubs and charts. LEGACY COMPONENT DESC: Navigational Publications and Charts
Condition: Unknown
Due 30 March 2002
Resolved 24 May 2002
Communications › Radio Communications
Issued 12 February 2002 Resolved
Provide FCC Ship Safety Certificate. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Due 30 March 2002
Resolved 24 May 2002
Documentation
Issued 12 February 2001 Resolved
PROVIDE A VALID FCC STATION LICENSE AND SAFETY RADIO CERTIFICATE. VESSEL IS RESTRICTED TO OPERATIONS WITHIN 1000 FEET FROM SHORE.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Unknown
Issued 12 February 2001 Resolved
PRIOR TO OPERATION WITH PASSENGERS, MAKE VESSEL AVAILABLE FOR INSPECTION BYCOGNIZANT [name withheld] ITEMS ISSUED BY PTCD 08FEB01.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Electrical
Issued 12 February 2001 Resolved
PROVIDE COPY OF CG APPROVED ELECTRICAL PLANS IN ACCORDANCE WITH 46 CFR 177.202.
Condition: Unknown
Due 12 March 2001
Resolved 18 March 2003

Casualty record · 2

14 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3716616
24 March 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3971741
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.