← All vessels
TERRAPIN STATION
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG East District (CGD-E) · Other hulls named TERRAPIN STATION
TERRAPIN STATION is a 2001 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2001, most recently in April 2026, along with 16 deficiencies and 1 casualty investigation in 2009.
Records from 2001 to 2026. Most recent: inspection, 21 April 2026.
- Built
- 2001
- Last inspected
- 21 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
1107098
WDL6543
20682
Flag
UNITED STATES
368151770
Maury page id
psix-20682
Inspections, by type
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 15.0 ft × 3.7 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMAN BOATS INC · MARION, MD, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEDGEWATER, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
17 - Simplified, Gross Ton
17 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ9109MMSI 368151770 · active · compulsorily equipped · granted 17 April 2026, expires 17 April 2036
WDL6543MMSI 368151770 · cancelled · compulsorily equipped · granted 26 June 2020, cancelled 14 April 2026
WDK3361MMSI 368044490 · cancelled · compulsorily equipped · granted 12 June 2018, cancelled 16 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDG2835MMSI 366803590 · expired · compulsorily equipped · granted 29 February 2012, cancelled 30 April 2022
WDA3905MMSI 366803590 · expired · compulsorily equipped · granted 15 March 2001, cancelled 21 May 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 34
21 April 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8353533
14 April 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8352861
17 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8311654
15 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8296814
9 June 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8156217
3 June 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7925746
26 May 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7710388
7 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7633430
22 August 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7540786
11 July 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7503556
3 March 2021
Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7149663
8 January 2020
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6885566
4 June 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6705116
28 June 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6458097
12 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6390928
28 March 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6118837
31 January 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6083862
2 January 2016
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5789744
1 May 2014
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4848065
5 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4106077
18 January 2011
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3930445
21 April 2009
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3457193
7 April 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3185523
4 February 2008
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3141608
2 March 2007
Annual Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2880724
29 March 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2612690
30 March 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2323222
23 February 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2297954
15 April 2004
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2044733
17 April 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1773374
1 April 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1765637
26 March 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1495090
28 March 2001
Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362384
7 March 2001
Plan Review "T" Boat · Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455963
Deficiency record · 16
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery. O/O reported that they hauled vessel to repair port shaft seal, but also found that they need to repair engine mount as well. O/O is to submit repair plans and make repairs to the satisfaction of the [name withheld] will conduct power trails.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 February 2026
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] and DD Exam, MI discovered several holes in the hull that need to be addressed prior to carry of passengers. There are several areas on the hull that need to be repaired. Submit repair plan to local OCMI for approval.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 July 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel had expired Alco Test strips onboard. 46 CFR4.06-15
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2022
Resolved
In a vessel of 12 meters or more in length but less than 50 meters in length:(i) A masthead light, 5 miles; except that where the length of the vessel is less than 20 meters, 3 miles. Vessel Masthead light was inoperable. 33 CFR 83.22
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessels First Aid kit contents were expired. 46 CFR 184.710
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 April 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel was unable to conduct abandon ship or man overboard drills at time of inspection.
46 CFR 176.808(g)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's STBD engine produced an alarm and was not operating properly while underway during course of inspection.
46 CFR 182.200(a)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021
Resolved
Each survival craft must be: Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Weak link missing from lifefloat painter rigging at time of inspection.
46 CFR 180.130(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021
Resolved
The lifefloat's painter must: Be stowed in such a way that it runs out freely when the life float or buoyant apparatus floats away from a sinking vessel. Marine inspector witnessed lifefloat painter improperly stowed at time of inspection.
180.175(f)(3)(iv)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021
Resolved
Life floats. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.Vessel's lifefloat was missing required paddles at time of inspection.
46 CFR 180.175(d)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 April 2021
Resolved
Each plug cock in an inlet or discharge pipe must have a means, other than a cotter pin, to prevent its loosening or removal from the body. Thru-hull fitting on vessel's stern not properly capped.
46 CFR 179.350(g)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 April 2021
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, the following restrictions apply: Flexible nonmetallic hose must be complete with factory- assembled end fittings requiring no further adjustment on the hose. Dead-ended flexible
hose without cap connected to disused water tank. Cap
hose fitting.
46 CFR 182.720(e)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. Required marking was missing from vessel's lifefloat at time of inspection.
46 CFR 185.604(e)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessel's fuel shutoff stations' stenciling was illegible at time of inspection.
46 CFR 185.608
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2021
Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel had only 2 fire buckets onboard at time of inspection.
46 CFR 181.610
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2020
Resolved
Provide Repair Proposal to address the wastage of metal on the shaft strut located on the starboard side. The zinc anode for the starboard strut was missing; which may have attributed to the wastage of metal.
Casualty record · 1
14 June 2009Routine · role: Sighted in Area · activity 3508200
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
CANVASBACK (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.