MAURY USCG vessel records Sign in
← All vessels

TERRAPIN STATION

TERRAPIN STATION is a 2001 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2001, most recently in April 2026, along with 16 deficiencies and 1 casualty investigation in 2009.

Records from 2001 to 2026. Most recent: inspection, 21 April 2026.

Built
2001
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL6543
Flag
UNITED STATES
368151770
Maury page id
psix-20682

Inspections, by type

Years with a record 22 calendar years (2001–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 15.0 ft × 3.7 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMAN BOATS INC · MARION, MD, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEDGEWATER, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
17 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9109MMSI 368151770 · active · compulsorily equipped · granted 17 April 2026, expires 17 April 2036
WDL6543MMSI 368151770 · cancelled · compulsorily equipped · granted 26 June 2020, cancelled 14 April 2026
WDK3361MMSI 368044490 · cancelled · compulsorily equipped · granted 12 June 2018, cancelled 16 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDG2835MMSI 366803590 · expired · compulsorily equipped · granted 29 February 2012, cancelled 30 April 2022
WDA3905MMSI 366803590 · expired · compulsorily equipped · granted 15 March 2001, cancelled 21 May 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

21 April 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8353533
14 April 2026 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8352861
17 February 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8311654
15 January 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8296814
9 June 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8156217
3 June 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7925746
26 May 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7710388
7 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7633430
22 August 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7540786
11 July 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7503556
3 March 2021 Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7149663
8 January 2020 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6885566
4 June 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6705116
28 June 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6458097
12 April 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6390928
28 March 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6118837
31 January 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6083862
2 January 2016 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5789744
1 May 2014 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4848065
5 August 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4106077
18 January 2011 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3930445
21 April 2009 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3457193
7 April 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3185523
4 February 2008 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3141608
2 March 2007 Annual Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2880724
29 March 2006 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2612690
30 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2323222
23 February 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2297954
15 April 2004 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2044733
17 April 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1773374
1 April 2003 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1765637
26 March 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1495090
28 March 2001 Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362384
7 March 2001 Plan Review "T" Boat · Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455963

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery. O/O reported that they hauled vessel to repair port shaft seal, but also found that they need to repair engine mount as well. O/O is to submit repair plans and make repairs to the satisfaction of the [name withheld] will conduct power trails.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2026
Resolution: MI attended vessel to exam repair and conduct sea trail/stress test of engine and components. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 February 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] and DD Exam, MI discovered several holes in the hull that need to be addressed prior to carry of passengers. There are several areas on the hull that need to be repaired. Submit repair plan to local OCMI for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2026
Resolution: Repairs to satisfaction of MI
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 July 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel had expired Alco Test strips onboard. 46 CFR4.06-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2022
Resolution: Received photo evidence of newly purchased/acquired Alcohol Test Strips
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2022 Resolved
In a vessel of 12 meters or more in length but less than 50 meters in length:(i) A masthead light, 5 miles; except that where the length of the vessel is less than 20 meters, 3 miles. Vessel Masthead light was inoperable. 33 CFR 83.22
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2022
Resolution: Received photographic evidence of newly installed and working masthead light
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 July 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessels First Aid kit contents were expired. 46 CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2022
Resolution: Received photographic evidence of newly purchased Firat Aid Kit
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 April 2021 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel was unable to conduct abandon ship or man overboard drills at time of inspection. 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Conducted successful MOB and simulated abandon ship drills while underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's STBD engine produced an alarm and was not operating properly while underway during course of inspection. 46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Conducted underway inspection; vessel's engines operating properly during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021 Resolved
Each survival craft must be: Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Weak link missing from lifefloat painter rigging at time of inspection. 46 CFR 180.130(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Weak link installed properly on lifefloat painter rigging.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021 Resolved
The lifefloat's painter must: Be stowed in such a way that it runs out freely when the life float or buoyant apparatus floats away from a sinking vessel. Marine inspector witnessed lifefloat painter improperly stowed at time of inspection. 180.175(f)(3)(iv)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Painter properly rigged to lifefloat and weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021 Resolved
Life floats. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.Vessel's lifefloat was missing required paddles at time of inspection. 46 CFR 180.175(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Lifefloat equipped with required paddles.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 April 2021 Resolved
Each plug cock in an inlet or discharge pipe must have a means, other than a cotter pin, to prevent its loosening or removal from the body. Thru-hull fitting on vessel's stern not properly capped. 46 CFR 179.350(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Thru-hull fitting properly capped.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 April 2021 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, the following restrictions apply: Flexible nonmetallic hose must be complete with factory- assembled end fittings requiring no further adjustment on the hose. Dead-ended flexible hose without cap connected to disused water tank. Cap hose fitting. 46 CFR 182.720(e)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 17 May 2021
Resolution: Dead-end flex hose properly capped and sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2021 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. Required marking was missing from vessel's lifefloat at time of inspection. 46 CFR 185.604(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 17 May 2021
Resolution: Capacity properly stenciled on vessel's lifefloat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessel's fuel shutoff stations' stenciling was illegible at time of inspection. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 17 May 2021
Resolution: Fuel shutoff stations possessed required, legible stenciling.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2021 Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel had only 2 fire buckets onboard at time of inspection. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 17 May 2021
Resolution: Third fire bucket properly installed onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2020 Resolved
Provide Repair Proposal to address the wastage of metal on the shaft strut located on the starboard side. The zinc anode for the starboard strut was missing; which may have attributed to the wastage of metal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 22 January 2020
Resolution: Starboard strut replaced. Dye penetrant test completed- sat. Sea trials- sat.

Casualty record · 1

14 June 2009Routine · role: Sighted in Area · activity 3508200
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CANVASBACK (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.