DEEP STIM III

DEEP STIM III is a 1982 offshore supply vessel. The Coast Guard has recorded 28 inspections since 1986, most recently in January 2011, along with 39 deficiencies and 1 casualty investigation in 2008.

Records from 1986 to 2011. Most recent: inspection, 11 January 2011.

Built
1982
Last inspected
11 January 2011
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8136544 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB4681
207056
Flag
UNITED STATES
369303000 (licence lapsed)
Maury page id
psix-207056

Inspections, by type

…with no type recorded8
Years with a record 16 calendar years (1986–2011)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)224.2 ft × 44.0 ft × 14.0 ft
Registered tonnagegross 1,951 / net 585
ITC dimensions (L × B × D)224.2 ft × 44.0 ft × 14.0 ft
ITC tonnagegross 1,951 / net 585
BuilderNORTH AMERICAN SHIPBLDG · LAROSE, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1951 - Convention (Subpart B), Gross Ton
585 - Convention (Subpart B), Net Ton
1609 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB4681MMSI 369303000 · expired · compulsorily equipped · granted 10 July 2003, cancelled 14 September 2013
WCQ4145MMSI not assigned · cancelled · voluntarily equipped · granted 22 March 1995, cancelled 4 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FAIRFIELD ENDEAVOR Unclassified · MISLE 49404 · 2 August 1995 · activity 62391FAIRFIELD NEW VENTURE Research Vessel · MISLE 265284 · 2 August 1995 · activity 62391KITTANNING * Tank Ship · MISLE 49047 · 28 August 1994 · activity 180721

Inspection history · 28

11 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3928625
26 March 2010 MTSA Verification · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3702993
16 April 2009 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3447953
15 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3427509
7 July 2008 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3263250
26 June 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3249596
26 June 2008 Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3249666
28 May 2008 Cargo Tank Internal · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3228710
29 December 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3124324
25 June 2007 Re-Inspection · Deficiency Check · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977540
18 October 2006 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2811409
11 September 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2775750
10 September 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2775714
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750276
8 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2657614
17 April 2006 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2626175
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502141
8 June 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2383589
6 May 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2060492
30 May 2003 Inclining Experiment · Construction Oversight · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1816826
14 October 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802998
17 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779991
2 August 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 62391
28 August 1994 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 180721
24 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854003
28 February 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1008690
23 April 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227752
22 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310703

Deficiency record · 39

Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2010 Resolved
Provide proper explosion proof lighting in chemical mixing (PCM) room.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 26 March 2010 Resolved
Repair battery room exhaust switches.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected.
Electrical › Electric Supply System (service) › Cable
Issued 26 March 2010 Resolved
Fix loose wires above aft door in client pump room.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Engineering › Compressed Air System (control) › Valve
Issued 26 March 2010 Resolved
Replace broken air (tank) receiver pressure relief valve.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 March 2010 Resolved
Provide adequate e-lighting for main engine room passageway by replacing batteries.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 26 March 2010 Resolved
Demonstrate proper operation of port generator overspped trips in client pump room.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Lifesaving › Rescue Boat › Markings
Issued 26 March 2010 Resolved
Stencil rescue boat with max capacity, hailing port and ship's name.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Deck/Cargo › Marine Portable Tanks › Base
Issued 26 March 2010 Resolved
Properly label all chemical tote tanks (portable tanks).
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 March 2010 Resolved
Provide adequate aft mast and stern light.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Electrical › Lighting (service) › Switch
Issued 26 March 2010 Resolved
Demonstrate proper operation of light switch in client P.C.M. room port side embarcation.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 14 June 2010
Resolution: corrected
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 16 April 2009 Resolved
Replace sump pump with mounted submersible pump, hard wired into vessel electrical system operated by mounted on/off switch. Pumps are located in shaft alley.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 11 June 2009
Engineering › Diesel Engine (propulsion-direct drive) › Piston Rod
Issued 26 June 2008 Resolved
Starboard MDE possibly threw a rod causing a 14 inch by 10 inch hole in the engine block. This caused a fire in the engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 August 2008
Resolution: Witnessed proper operation of Stbd MDE and all automation.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 June 2008 Resolved
Secure back panel on main switchboard.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 6 June 2008 Resolved
Double nut all shaft packings.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Engineering › Bilge Water Management System › Pump
Issued 6 June 2008 Resolved
Remove sump pump from cofferdams and replace with approved submersible pumps.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 6 June 2008 Resolved
EEBA bottle in engine room needs hydrostatic test.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Documentation › Markings/Placards › Warning Signs
Issued 6 June 2008 Resolved
Provide CO2/General Alarm placard in engine room.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Engineering › Steering Gear System › Rudder
Issued 6 June 2008 Resolved
Renew / repair port rudder packing.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 6 June 2008 Resolved
Remove installed tool box from in front of e-light in client space.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 6 June 2008 Resolved
Remount fire alarm in pump room.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 June 2008 Resolved
Renew all life jackets in engine room.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 6 June 2008 Resolved
Repair fuel lines in client space, replace flexible lines with hard lines.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 6 June 2008 Resolved
Remove paint from all vent closure devices.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Construction/Loadline › Structures › Door
Issued 6 June 2008 Resolved
Adjust various watertight doors.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2008 Resolved
Secure all deck plates in machinery spaces.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 6 June 2008 Resolved
Provide high noise headset for engine room.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 15 August 2008
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 6 June 2008 Resolved
Complete automation test and add emergency generator to automation plans.
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 6 June 2008
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 25 June 2007 Resolved
PROVIDE PROPOSAL FOR ADDITION OF REQUIRED EMERGENCY POWER SOURCE IN COMPLIANCE WITH 46 cfr SUBCHAPTER J & L TO INCLUDE ANALYSIS & PROPOSALS TO MITIGATE IMPACTS WITH SERIOUS CONSIDERATION OF IMMEDIATEADDITION OF LOAD SHEDDING FOR VITAL SYSTEMS. (REINFORCES OUTSTANDING REQUIREMENT OF 17APR06 & 23OCT06)
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 6 June 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 25 June 2007 Resolved
Mount 2nd emergency light in port E/R emergency escape
Due 25 July 2007
Resolved 29 June 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 June 2007 Resolved
Mark emergency exits in pump room
Due 25 July 2007
Resolved 29 June 2007
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 25 June 2007 Resolved
Seal pump room penetrations on main deck
Due 25 July 2007
Resolved 29 June 2007
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 20 October 2006 Resolved
Provide proposal for addition of required emergency power source in compliance with 46 CFR Subchapters J & L NLT Nov 30, 2006 to include analysis and proposals to mitigate recurring loss of power & means to mitigate impacts with serious consideration of immediate addition of load shedding for vital systems. (modifies requirement dtd 4/17/06)
Condition: Unknown
Due 30 November 2006
Resolved 6 June 2008
Lifesaving › Rescue Boat › Markings
Issued 17 April 2006 Resolved
Rescue boat is not marked IAW 46CFR131.855
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 1 May 2006
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 17 April 2006 Resolved
Provide powered winch motor for launching/recovery IAW 46CFR133.160(e)
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 27 October 2006
Resolution: [name withheld] emailed digital photos and report of successful installation.
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 April 2006 Resolved
Provide
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 1 May 2006
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 17 April 2006 Resolved
Provide and maintain.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 1 May 2006
Engineering › Pressure Vessel › Marking and Stamping
Issued 17 April 2006 Resolved
Provide ASME certifications for 3 air receivers in client pump room.
Due 5 May 2006
Resolved 26 May 2006
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 April 2006 Resolved
Demonstrate compliance/Provide evidence of compliance with 46CFR112.01
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 6 June 2008
Resolution: Witnessed installation and operation of emergency generator.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 17 April 2006 Resolved
Amend Automation test procedures to include fire/smoke detectors.
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 25 June 2007

Casualty record · 1

26 June 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3249596
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.