ATLANTIC CITY PRINCESS

ATLANTIC CITY PRINCESS is a 1982 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1988, most recently in March 2014, along with 101 deficiencies — 1 with no resolution recorded —.

Records from 1988 to 2014. Most recent: inspection, 5 March 2014.

Built
1982
Last inspected
5 March 2014
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD8841
207164
Flag
UNITED STATES
367303440 (licence lapsed)
Maury page id
psix-207164

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (1988–2014)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.1 ft × 20.1 ft × 7.0 ft
Registered tonnagegross 72 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY SHOP INC · JEFFERSONVILLE, IN, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Simplified, Gross Ton
58 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD8841MMSI 367303440 · expired · compulsorily equipped · granted 17 July 2007, cancelled 16 September 2017 · licensed under a name not among this hull’s recorded names (not shown)
WCX3909MMSI not assigned · expired · compulsorily equipped · granted 8 April 1997, cancelled 10 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

5 March 2014 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4810731
21 February 2012 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4247976
8 September 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4139432
21 July 2011 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4090240
8 January 2009 Deficiency Check · Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3391214
22 July 2008 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3275932
14 February 2008 Examination of Repairs · Hull Examination · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3147418
24 September 2007 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3064906
4 May 2007 Construction Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2924000
10 July 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2708544
4 May 2005 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2310885
29 March 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2347410
28 July 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2221370
30 July 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1924841
30 July 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1653766
6 March 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1490817
26 July 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1395822
27 April 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1064781
24 April 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1062385
22 March 2001 Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1450594
18 October 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373195
5 May 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1445633
5 April 2000 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 816477
21 March 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1458730
8 November 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 802993
24 June 1999 Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1413568
7 June 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1402903
16 April 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1456683
8 June 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792905
24 March 1998 Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1122843
8 August 1997 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1117904
29 July 1997 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1119464
9 April 1997 Plan Review "T" Boat · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1418283
20 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088644
12 June 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1454460
14 October 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 833430
28 May 1993 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 837786
18 December 1992 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1133076
17 September 1992 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1134260
27 March 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1254953
13 January 1992 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 954365
12 December 1991 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 947968
10 December 1991 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1258025
27 March 1991 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 906120
24 April 1990 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 911607
27 March 1990 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1235197
13 April 1989 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1210202
6 April 1989 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1043033
17 March 1989 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1037540
17 March 1989 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1344889
15 September 1988 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1036447
11 May 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1042474
18 March 1988 Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 890750

Deficiency record · 101

Construction/Loadline › Hull › Bottom Plating
Issued 8 September 2011 Resolved
Provide proof of vessel scantling or provide proof that the vessel as originally constructed is fit for operation in a Lakes, Bays and Sounds route.
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 26 October 2011
Resolution: Received a letter from the representative of the yard where the vessel was constructed stating the vessel was constructed to 3/16 scantlings.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 July 2011 Resolved
Provide three 03 alcohol test kits.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O purchased 03 alcohol test kits.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2011 Resolved
Provide eye wash and aspirin.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O purchased eye wash and aspirin.
Fire Fighting › Fire Pumps › Pressure
Issued 21 July 2011 Resolved
Repair fire pump and conduct operational test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O found impeller clogged with an eel. O/O repaired pump and proved proper operation.
Engineering › Bilge Water Management System › Pump
Issued 21 July 2011 Resolved
Prove proper operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O proved proper operation of pump and pumped out steering gear room.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 July 2011 Resolved
Battery connections on MDE and SSDG start batteries are loose.
Condition: Improper/Lack of Maintenance
Due 4 August 2011
Resolved 27 July 2011
Resolution: O/O retightened all battery cables.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 July 2011 Resolved
Engine room starboard side ventilation duct is disconnected from the ventilation fan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O properly connected starboard side ventilation duct.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 July 2011 Resolved
Install outlet cover for outlet in E/R stbd. side aft.
Condition: Improper Installation
Due 4 August 2011
Resolved 27 July 2011
Resolution: O/O purchased and installed new outlet cover.
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 July 2011 Resolved
Replace volt meter on shore tie breaker panel.
Condition: Improper/Lack of Maintenance
Due 4 August 2011
Resolved 27 July 2011
Resolution: O/O purchased and installed new volt meter.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 21 July 2011 Resolved
Starboard side tank is over charged by 100psi.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O has system serviced. Servicing report is in vessel file.
Fire Fighting › Fixed Gas Fire Extinguishing System › Nozzle
Issued 21 July 2011 Resolved
Portside bottle is missing the cap, and the pull cable is improperly installed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: O/O had system serviced. Service report is in vessel file.
Lifesaving › Lifefloat › Serviceable
Issued 8 January 2009 Resolved
Provide repairs and proper installation of vessel's lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2009
Resolution: Vessel installed lifefloats correctly on vessel with weak link, 100'' of painter.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 22 July 2008 Resolved
Instructed owner to purchase a weak-link for each LF and install to the satisfation of the attending MI.
Due 31 October 2008
Resolved 22 September 2008
Resolution: Owner will contact this office when the lifefloat is installed. MI will inspect installation prior to operating on Nov 1.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 July 2008 Resolved
Properly secure several outlet boxes on the vessel that were loose.
Due 22 August 2008
Resolved 22 September 2008
Resolution: All electrical boxes were secured correctly.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 July 2008 Resolved
Purchase and install mounting brackets for 03 portable fire extinguishers.
Due 25 July 2008
Resolved 30 July 2008
Resolution: Mounting brackets were purchased for all fire extinguishers and placed in service.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 July 2008 Resolved
Replace line with UV resistant line.
Due 22 August 2008
Resolved 22 September 2008
Resolution: Line was replaced w/ 60 ft of uv resistant line.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 July 2008 Resolved
Permanently mount junction box for potable water pump.
Due 22 August 2008
Resolved 22 September 2008
Resolution: Juntion box was properly mounted.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 July 2008 Resolved
Provide a permanent mounting for the H/W heater.
Due 22 August 2008
Resolved 22 September 2008
Resolution: H/W heater was mounted correctly.
Electrical › Lighting (service) › Outlet Box
Issued 22 July 2008 Resolved
Provide cover for outlet box on step leading to stateroom.
Due 22 August 2008
Resolved 22 September 2008
Resolution: Repairs made to the satisfaction of MI.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 22 July 2008 Resolved
Vessel's main fire pump inop. This pump was previously rebuilt but has failed for the second straight annual inspection. Owner will purchase and install new pump to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2008
Resolution: Fire pump seal was replaced and tested, sat. Both main and auxillary fire pumps achieved working pressure.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 February 2008 Resolved
Permanently mount outlet boxes (02) located in water heater space.
Due 3 March 2008
Resolved 31 March 2008
Resolution: Electrical outlet boxes were mounted permanently.
Fire Fighting › Fire Hydrants › Condition
Issued 14 February 2008 Resolved
Crop out/renew stand pipe for fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2008
Resolution: Vessel replaced in-kind.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 February 2008 No resolution recorded
Gas free diesel oil tanks and crop out/renew, all fill pipes and vents to the satisfaction of the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolution: All fuel pipes/vents were replaced.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2008 Resolved
Provide plan proposal for repairs to thin hull plating at the starboard bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2008
Resolution: Soundings were made and area of the hull was removed and replaced to ABS standards.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2008 Resolved
Provide plan proposal for renewing of metal around the superstructure to the satisfaction of the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2008
Resolution: Plan provided for repair to superstructure, approved. Inspection of supporting structures revealed no damage requiring extensive repairs. Metal was replaced to affected areas on the superstructure.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2008 Resolved
Provide plan proposal for removal of scale in the water heater compartment and provide UT for the area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2008
Resolution: Soundings were made and area of the hull was removed and replaced to ABS standards.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2008 Resolved
Remove standing water from bilge area in master stateroom head area and inspect area for scale.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2008
Resolution: Standing water was removed from area and UT was conducted in the surrounding area. Results showed significant wear to the hull plating and will be renewed.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2008 Resolved
Provide UT in areas discussed with the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2008
Resolution: Soundings were made to areas of the hull and bad metal was removed and replaced to ABS standards.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2008 Resolved
Provide plan proposal for the removal of the swim platform and repair of areas to the transom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2008
Resolution: Swim platform was replaced "in-kind" and welds inspected, sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 September 2007 Resolved
Vessel Owner requested an update to COI to reflect new Hailing Port and Address.
Due 1 November 2007
Resolved 8 April 2008
Resolution: Information on current COI is correct.
Engineering › Bilge Water Management System › Pump
Issued 4 May 2007 Resolved
Show proper operation of primary and secondary bilge/fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2007
Resolved 4 May 2007
Resolution: Made repairs to pump and showed proper operation. Verified by Marine Inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 4 May 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 13 July 2007
Resolved 16 July 2007
Resolution: Provided proof that forms have been submitted for renewal.
Construction/Loadline › Structures › Machinery Space Opening
Issued 4 May 2007 Resolved
Repair port light covering in engine room (port side forward window) port light to allow window to be dogged shut.
Due 31 May 2007
Resolved 24 May 2007
Resolution: Provided new dogs to allow for proper operation of port light. Verified by marine inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 July 2006 Resolved
Provide proof of enrollment of crew in drug and alcohol testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Received fax from Maritime Drug Consortium containing names of crew enrolled.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 July 2006 Resolved
Provide operational high water alarm for forward compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2006
Resolution: Corrosion found in connectors at switch. Conducted operational test of alarm, sat. Verified by marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2006 Resolved
Remove wire nuts from light in forward compartment and replace with a permanent type splice.
Due 31 July 2006
Resolved 12 July 2006
Resolution: Removed several wire nut splices throughout vsl. Verified by marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2006 Resolved
Add additional electrical outlets and remove extension cords that are being permanently used.
Due 11 August 2006
Resolved 14 September 2006
Resolution: Removed all unnecessary electrical items from space that are not always in use and removed all extension cords. No additional outlets were needed once space was cleaned up.
Engineering › Bilge Water Management System › Piping
Issued 10 July 2006 Resolved
Through hull valves from old bilge system in engine room need to have caps installed on valves at hull penetration.
Due 31 July 2006
Resolved 12 July 2006
Resolution: Through hull valves have been capped. Verified by marine inspector.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 4 May 2005 Resolved
Provide a current FCC Safety Certificate.
Due 5 June 2005
Resolved 16 August 2005
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2005 Resolved
Crop and renew to good steel, the area around the port and starboard exhaust ports.
Due 29 April 2005
Resolved 5 May 2005
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2005 Resolved
Grind down and reweld the generator exhaust.
Due 29 April 2005
Resolved 5 May 2005
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2005 Resolved
Grind down and recoat all areas of rust below the water line.
Due 29 April 2005
Resolved 8 April 2005
Construction/Loadline › Hull › Side Shell
Issued 29 March 2005 Resolved
Grind down coat and renew the seals around all the port lights with rust around them.
Due 30 April 2005
Resolved 5 May 2005
Construction/Loadline › Structures › Superstructure
Issued 29 March 2005 Resolved
Grind down and recoat all areas of rust above the water line.
Due 30 April 2005
Resolved 5 May 2005
Fire Fighting › Emergency Fire Pumps
Issued 30 July 2002 Resolved
Replace or repair the gage for the fire pump. LEGACY COMPONENT DESC: Pressure Gage
Due 30 August 2002
Resolved 19 December 2002
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 July 2002 Resolved
PROVIDE PROOF OF ENROLLMENT IN CURRENT DRUG TESTING PROGRAM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2002
Engineering › Bilge Water Management System
Issued 30 July 2002 Resolved
REPAIR HIGH WATER ALARM IN AFT MOST COMPARTMENT. LEGACY COMPONENT DESC: HIGH WATER ALARM
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2002
Engineering › Shafting/Propeller Arrangements
Issued 6 March 2002 Resolved
Renew bent Port Rudder to original operating condition. LEGACY COMPONENT DESC: Rudder
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2002
Construction/Loadline › Hull
Issued 6 March 2002 Resolved
Renew/replace wasted steel around old exhaust ports. LEGACY COMPONENT DESC: Side Shell
Due 6 April 2002
Resolved 1 May 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 March 2002 Resolved
Renew insulation on Starboard Engine exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 6 April 2002
Resolved 1 May 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 6 March 2002 Resolved
Address small leak in Starboard Engine Keel Cooler piping. LEGACY COMPONENT DESC: Piping
Due 6 April 2002
Resolved 1 May 2002
Deck/Cargo › Holds/Tanks
Issued 6 March 2002 Resolved
Address leak into aft compartment through hatch cover. LEGACY COMPONENT DESC: Hatch Cover
Due 6 April 2002
Resolved 1 May 2002
Construction/Loadline
Issued 5 May 2000 Resolved
MEET SUBDIVISION REQUIREMENTS OF 46CFR 178 & 179.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Accommodation/Occupational Safety
Issued 5 May 2000 Resolved
LABEL UPPER DESK FOR MAX NUMBER OF PASSENGERS AS PER STABILITY LETTER.
Condition: Unknown
Due 5 May 2000
Resolved 7 June 2000
Lifesaving
Issued 5 May 2000 Resolved
PROVIDE WEAK LINK OR 200' LINE FOR EACK LF ALONG W/ WATERLIGHTS AND LABEL LF AND PADDLES W/ VSL NAME. TO BE COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 5 May 2000 Resolved
PROVIDE AUDIBLE ALARM FOR FWD AND AFT HIGH WATER BILGE ALARMS.
Condition: Unknown
Due 5 May 2000
Resolved 7 June 2000
Electrical
Issued 24 June 1999 Resolved
Hard wire all bilge pumps.
Condition: Unknown
Due 24 June 1999
Resolved 6 July 1999
Construction/Loadline
Issued 24 June 1999 Resolved
Submit plan for deck repair to area under stairs leading to aft deck.
Condition: Unknown
Due 24 June 1999
Resolved 6 July 1999
Construction/Loadline
Issued 24 June 1999 Resolved
Meet subdivision requirements in 46CFR 178 & 179 by November 1, 1999.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
Provide draft marks, fore and aft, both sides of the vessel.
Condition: Unknown
Due 24 June 1999
Resolved 6 July 1999
Construction/Loadline
Issued 7 June 1999 Resolved
Provide audible alarm for high-bilge level alarm.
Condition: Unknown
Due 21 June 1999
Resolved 2 July 1999
Navigation
Issued 7 June 1999 Resolved
Provide and post a emergency radio broadcast placard.
Condition: Unknown
Due 8 June 1999
Resolved 2 July 1999
Lifesaving
Issued 7 June 1999 Resolved
Provide clip for ring buoy waterlight.
Condition: Unknown
Due 8 June 1999
Resolved 2 July 1999
Documentation
Issued 7 June 1999 Resolved
Provide valid vessel documentation.
Condition: Unknown
Due 21 June 1999
Resolved 2 July 1999
Construction/Loadline
Issued 7 June 1999 Resolved
Prove proper operation of aft bilge pump prior to carrying passengers.
Condition: Unknown
Due 8 June 1999
Resolved 2 July 1999
Lifesaving
Issued 7 June 1999 Resolved
Vessel is restricted to a maximum of 80 Adults and 11 children.
Condition: Unknown
Due 21 June 1999
Resolved 2 July 1999
Fire Fighting
Issued 7 June 1999 Resolved
Provide pressure gauge at fire pump outlet.
Condition: Unknown
Due 21 June 1999
Resolved 2 July 1999
Unknown
Issued 7 June 1999 Resolved
Provide proof of enrollment in drug testing program for all employees undersame employer.
Condition: Unknown
Due 21 June 1999
Resolved 2 July 1999
Documentation
Issued 7 June 1999 Resolved
Provide valid FCC Safety Certificate.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 14 October 1993 Resolved
PROVIDE PROPER HAND LINES FOR TWO MAIN DECK LIFE RING BOUYS AND OPERATIONALWATERLIGHT FOR UPPER DECK LIFE RING BOUY BEFORE PASSENGERS ARE PERMITTED ONBOARD.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Construction/Loadline
Issued 14 October 1993 Resolved
MARK VESSEL NAME ON PORT AND STARBOARD BOW IN CONTRASTING CHARACTERS AT LEAST 4 INCHES IN HEIGHT PRIOR TO CARRYING PASSENGERS ON BOARD.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Lifesaving
Issued 14 October 1993 Resolved
CORRECTLY INDICATE THE NUMBER AND TYPE OF PFDS STORED IN LOCKERS PRIOR TO CARRYING PASSENGERS ON BOARD.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Documentation
Issued 14 October 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Documentation
Issued 14 October 1993 Resolved
PROVIDE PROOF OF EMPLOYEE PARTICIPATION IN PRE-EMPLOYMENT AND ANNUAL RANDOMDRUG/CHEMICAL TESTING PRIOR TO CARRYING PASSENGERS ON BOARD.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Documentation
Issued 28 May 1993 Resolved
PROVIDE PROOF OF EMPLOYEE PARTICIPATION IN PRE-EMPLOYMENT AND ANNUAL RANDOMDRUG/CHEMICAL TESTING.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 28 May 1993 Resolved
CORRECTLY INDICATE THE NUMBER AND TYPE OF PFDS STORED IN LOCKERS.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Construction/Loadline
Issued 28 May 1993 Resolved
MARK VESSEL NAME ON PORT AND STBD BOW IN CONTRASTING CHARACTERS AT LEAST 4 INCHES IN HEIGHT.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 28 May 1993 Resolved
PROVIDE PROPER HAND LINES FOR TWO MAIN DECK LIFE RING BOUYS AND OPERATIONALWATERLIGHT FOR UPPER DECK LIFE RING BOUY.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Documentation
Issued 28 May 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Fire Fighting
Issued 27 March 1992 Resolved
HAVE ALL FIRE EXTINGUISHERS SERVICED PRIOR TO THE CARRIAGE OF PASSENGERS, BUT NO LATER THAN 30APR92.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Engineering
Issued 27 March 1992 Resolved
REPLACE ALL HOSE AND HOSE END FITTINGS ON ALL FUEL LINES WITH HOSE AND END FITTINGS OF AN APPROVED TYPE, INSTALL PROPER PIPING TO ALLEVIATE LONG LENGTHS OF FUEL HOSE.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Engineering
Issued 27 March 1992 Resolved
CONTACT OCMI PRIOR TO 15APR92 TO SCHEDULE U/W MACHINERY TRIALS.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Lifesaving
Issued 27 March 1992 Resolved
OBTAIN 4 RED FLARES TOREPLACE ONES THAT EXPIRE APR92.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Fire Fighting
Issued 27 March 1992 Resolved
REPAIR LEAK AT WELD JOINT IN STANDPIPE ON PORT FIRE STATION.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Fire Fighting
Issued 27 March 1992 Resolved
RELOCATE FIRE AXE TO WHEELHOUSE.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Navigation
Issued 27 March 1992 Resolved
INSTALL PROPER BULBS IN BOTH P & S NAVLIGHT FIXTURES, VESSEL LIMITED TO DAYLIGHT OPS TIL CORRECT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Accommodation/Occupational Safety
Issued 27 March 1992 Resolved
RAISE ALL RAIL HEIGHTS TO 42", ENCLOSE AREA BELOW TOP RAIL WITH WIREMESH, FENCING OR SUCH MATERIAL.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Documentation
Issued 27 March 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Navigation
Issued 17 March 1989 Resolved
ADD SCREENING TO THE MASTHEAD LIGHT TO PROVIDE THE PROPER ARC OF VISIBILITY
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 17 March 1989 Resolved
REPOSITION THE STERN LIGHT SO THAT IT DISPLAYS THE CORRECT ARC OF VISIBILITY AND IS NOT OBSCURED BY THE COCKPIT STEPS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 18 March 1988 Resolved
MARK ALL VESSEL LIFE RINGS, ATTACH 60' OF LINE TO ONE LIFE RING AND ATTACH THE WATER LIGHT TO THE LIFE RING AT THE PILOT HOUSE. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Construction/Loadline
Issued 18 March 1988 Resolved
PROVIDE PROPER FLAME SCREENS FOR THE VENTS FOR BOTH FUEL OIL TANKS. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Construction/Loadline
Issued 18 March 1988 Resolved
DRYDOCK THE VESSEL FOR CREDIT HULL EXAM.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Unknown
Issued 18 March 1988 Resolved
PROVIDE AND POST AN EMERGENCY CHECK OFF LIST. THIS ITEM IS TO BE COMPLETEDPRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Lifesaving
Issued 18 March 1988 Resolved
PROPERLY MARK LIFE STOWAGE LOCKERS, THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Fire Fighting
Issued 18 March 1988 Resolved
CONNECT AND PROVE THE OPERATION OF THE HALON ACTUATED SHUT DOWN SYSTEM FOR ENGINE ROOM VENTILATION SYSTEMS, THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Navigation
Issued 18 March 1988 Resolved
MAKE THE SIDE SCREENS MATT BLACK AND ENSURE THAT THE LIGHT IS RESTRICTED TOTHE PROPER HORIZONAL SECTORS, THIS ITEM IS TO BE COMPLETED PRIOR TO OPERAT-ING THE VESSEL AT NIGHT.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Lifesaving
Issued 18 March 1988 Resolved
PROVIDE 5 ADDITIONAL TYPE I ADULT LIFE JACKETS TO BRING THE TOTAL NUMBER OFJACKETS ON BOARD TO 55.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Unknown
Issued 18 March 1988 Resolved
PROVIDE THE FOLLOWING "AS IS" VESSEL DRAWINGS:
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Fire Fighting
Issued 18 March 1988 Resolved
PROVIDE SUCTION AND DISCHARGE HOSES FOR THE PORTABLE HAND OPERATED FIRE/BILGE PUMP. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Construction/Loadline
Issued 18 March 1988 Resolved
PROPERLY MARK THE EMERGENCY SHUT OFF VALVES FOR THE FUEL OIL TANKS, THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.