Records from 1989 to 2016. Most recent: inspection, 10 August 2016.
Inspection history · 44
10 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6011859
10 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4241960
2 April 2009
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3444714
20 October 2008
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3348615
17 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3081480
27 February 2007
COI Inspection · Ballast Water Examination · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2878734
11 April 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1771938
6 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1615490
16 March 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445766
19 October 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446832
6 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465421
9 September 1998
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 799283
23 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 176585
23 November 1997
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109954
22 October 1997
Examination of Repairs · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435983
28 April 1997
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433186
18 October 1996
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356029
10 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396377
19 September 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400234
20 October 1994
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440878
24 February 1994
Examination of Repairs · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440776
6 January 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394012
28 September 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409019
20 September 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356411
24 September 1992
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261755
26 May 1992
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954864
31 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263573
13 January 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 955130
16 December 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259965
15 December 1991
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950739
10 December 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943366
10 December 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949175
30 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251391
1 October 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246841
20 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219169
27 September 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1214607
7 September 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911620
4 June 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 926540
3 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211869
5 March 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921985
2 March 1990
Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218237
21 November 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233330
21 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233682
13 October 1989
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1034071
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2009
Resolved
Properly re-wire the feed cable for the port sump pump under the shaft coupling.
Due 9 April 2009
Resolved 3 April 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 April 2009
Resolved
Install a proper lanyard for the floating light on one lifering on deck.
Due 9 April 2009
Resolved 3 April 2009
Navigation › Collision/Grounding Avoidance
Issued 11 April 2003
Resolved
Replace burnt nav light bulb. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2003
Resolution: Bulb replaced.
Lifesaving › Buoyant Apparatus
Issued 6 May 2002
Resolved
Restowe life floats in float free arrangement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2002
Resolution: Corrected prior to sailing.
Lifesaving
Issued 16 March 2001
Resolved
EXPIRED HYDROSTATIC RELEASE.
Condition: Unknown
Due 16 March 2001
Resolved 21 March 2001
Fire Fighting
Issued 16 March 2001
Resolved
INADEQUATE PRESSURE.
Condition: Unknown
Due 16 March 2001
Resolved 21 March 2001
Construction/Loadline
Issued 23 November 1997
Resolved
MAKE PERMANENT REPAIRS TO COLLISION DAMAGE INCLUDING BUT NOT LIMITED TO PORT SIDE APRON AND HAND RAILS.
Condition: Unknown
Due 23 November 1997
Resolved 23 November 1997
Documentation
Issued 22 October 1997
Resolved
PROVE COMPLIANCE WITH THE DRUG TESTING PROGRAMS OF 46 CFR PART 16.
Condition: Unknown
Due 22 November 1997
Resolved 23 October 1997
Construction/Loadline
Issued 19 September 1995
Resolved
Clean aft steering compt., inspect for broken frame/longitudinal welds, repair as necessary, insure special welding requirements are met.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Navigation
Issued 19 September 1995
Resolved
Replace all old navigation & tide publications with current up to date pubs. (Old pubs are 92/93)
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Construction/Loadline
Issued 19 September 1995
Resolved
Renew shaft packing in port & stbd shaft packing glands.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Deck/Cargo
Issued 19 September 1995
Resolved
Take gauge readings on the forward leg supports, gussets & leg sleve, renewall metal per original drawing specs that exceeds or equals 25%, insure special welding requirements are met.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Navigation
Issued 19 September 1995
Resolved
Repair/renew steering jockey bar pin holes & both clevis pins, excessive play in both areas.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Documentation
Issued 19 September 1995
Resolved
FCC license is expired/renew & provide copy of new license.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Electrical
Issued 19 September 1995
Resolved
Renew battery boxes in engine room.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Deck/Cargo
Issued 19 September 1995
Resolved
Renew hydraulic anti-vibration clamps on brake hoses for forward jacking leg.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Navigation
Issued 20 October 1994
Resolved
Repair as original,starboard rudder to provide adequate clearance at lower rudder support.
Condition: Unknown
Due 27 October 1994
Resolved 1 November 1994
Electrical
Issued 20 October 1994
Resolved
Replace damaged electrical wire leading from port ships service generator.
Condition: Unknown
Due 27 October 1994
Resolved 1 November 1994
Engineering
Issued 28 September 1993
Resolved
PERMANENT REPAIRS MADE TO PORT ENGINE WATER COOLING SYSTEM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1993
Resolved 29 September 1993
Engineering
Issued 20 September 1993
Resolved
MAKE PERMANENT REPAIRS TO PORT ENGINE WATER COOLING SYSTEM, REMOVE RED HANDAND REPAIR AS NECESSARY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1993
Resolved 27 October 1993
Engineering
Issued 24 September 1992
Resolved
REPLACE WATER HEATER RELIEF VALVE WITH PRESSURE/TEMPERATURE RELIEF VALVE SET AT NOT MORE THAN 100 PSI/210 DEGREES FAHRENHEIT, OR MAKE WATER HEATER AVAILABLE FOR INTERNAL INSPECTION_x001C_ _x001C_
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Documentation
Issued 24 September 1992
Resolved
PROVIDE TO MSO NEW ORLEANS APPROVED STABILITY LETTER.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Documentation
Issued 13 October 1989
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM #1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Documentation
Issued 13 October 1989
Resolved
SUBMIT STABILITY CALCULATIONS TO THE MARINE SAFETY CENTER, WASHINGTON, D.C.FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Documentation
Issued 13 October 1989
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Documentation
Issued 13 October 1989
Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION. ORIGINAL IS TO BE PLACED 0N BOARD THE VESSEL.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Lifesaving
Issued 13 October 1989
Resolved
PROVIDE A U.S. COAST GUARD APPROVED RESCUE BOAT OR SUBMIT AN ALTERNATE PROPOSAL FOR APPROVAL.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Navigation
Issued 13 October 1989
Resolved
PROVIDE ONE (01) METER SPACING OF VERTICAL NAVIGATION LIGHTS ON MAST AS PER33 CFR PART 81-72 COLREGS ANNEX I.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Lifesaving
Issued 13 October 1989
Resolved
REPLACE LIFE FLOAT WEAK LINK WITH PROPER RATED WEAK LINK FOR 15 PERSON LIFEF FLOAT.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 13 October 1989
Resolved
PROVIDE ALL FIRE EXTINGUISHERS WITH COAST GUARD APPROVED MARINE TYPE MOUNTING BRACKETS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Engineering
Issued 13 October 1989
Resolved
REPLACE PETCOCKS IN ALL RACOR FUEL FILTERS WITH PIPE PLUGS OR PETCOCKS WITHPIPE PLUGS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Lifesaving
Issued 13 October 1989
Resolved
PROVIDE EMBARKATION MEANS TO COMPLY WITH 46 CFR 108.525.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Documentation
Issued 13 October 1989
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989